1.
Polymers (Basel) ; 16(10)2024 May 16.
Article in English | MEDLINE | ID: mdl-38794609

ABSTRACT

Over the last decade, researchers have developed a variety of new analytical and clinical diagnostic devices. These devices are predominantly based on microfluidic technologies, where biological samples can be processed and manipulated for the collection and detection of important biomolecules. Polydimethylsiloxane (PDMS) is the most commonly used material in the fabrication of these microfluidic devices. However, it has a hydrophobic nature (contact angle with water of 110°), leading to poor wetting behavior and issues related to the mixing of fluids, difficulties in obtaining uniform coatings, and reduced efficiency in processes such as plasma separation and molecule detection (protein adsorption). This work aimed to consider the fabrication aspects of PDMS microfluidic devices for biological applications, such as surface modification methods. Therefore, we studied and characterized two methods for obtaining hydrophilic PDMS surfaces: surface modification by bulk mixture and the surface immersion method. To modify the PDMS surface properties, three different surfactants were used in both methods (Pluronic® F127, polyethylene glycol (PEG), and polyethylene oxide (PEO)) at different percentages. Water contact angle (WCA) measurements were performed to evaluate the surface wettability. Additionally, capillary flow studies were performed with microchannel molds, which were produced using stereolithography combined with PDMS double casting and replica molding procedures. A PDMS microfluidic device for blood plasma separation was also fabricated by soft lithography with PDMS modified by PEO surfactant at 2.5% (v/v), which proved to be the best method for making the PDMS hydrophilic, as the WCA was lower than 50° for several days without compromising the PDMS's optical properties. Thus, this study indicates that PDMS surface modification shows great potential for enhancing blood plasma separation efficiency in microfluidic devices, as it facilitates fluid flow, reduces cell aggregations and the trapping of air bubbles, and achieves higher levels of sample purity.

2.
Nanomaterials (Basel) ; 12(15)2022 Jul 22.
Article in English | MEDLINE | ID: mdl-35893494

ABSTRACT

Fluids containing colloidal suspensions of nanometer-sized particles (nanofluids) have been extensively investigated in recent decades with promising results. Driven by the increase in the thermal conductivity of these new thermofluids, this topic has been growing in order to improve the thermal capacity of a series of applications in the thermal area. However, when it comes to measure nanofluids (NFs) thermal conductivity, experimental results need to be carefully analyzed. Hence, in this review work, the main traditional and new techniques used to measure thermal conductivity of the NFs are presented and analyzed. Moreover, the fundamental parameters that affect the measurements of the NFs' thermal conductivity, such as, temperature, concentration, preparation of NFs, characteristics and thermophysical properties of nanoparticles, are also discussed. In this review, the experimental methods are compared with the theoretical methods and, also, a comparison between experimental methods are made. Finally, it is expected that this review will provide a guidance to researchers interested in implementing and developing the most appropriate experimental protocol, with the aim of increasing the level of reliability of the equipment used to measure the NFs thermal conductivity.

3.
Biomed Microdevices ; 24(2): 20, 2022 06 07.
Article in English | MEDLINE | ID: mdl-35670892

ABSTRACT

The efficient separation of blood components using microfluidic systems can help to improve the detection and diagnosis of several diseases, such as malaria and diabetes. Therefore, a novel multi-step microfluidic device, based on passive crossflow filters was developed. Three different designs were proposed, fabricated and tested in order to evaluate the most suitable geometry to perform, simultaneously, blood cells separation and cell deformability measurements. All the proposed geometries include a main channel and three sequential separation steps, all comprised of symmetrical crossflow filters, with multiple rows of pillars, to reduce the amount of red blood cells (RBCs) flowing to the outlets of the microfluidic device (MD). Sets of hyperbolic constrictions located at the outlets allow the assessment of cells deformability. Based on the proposed geometries, the three correspondent MD were evaluated and compared, by measuring the RBCs velocities, the cell-free layer (CFL) effect through the microchannels and by quantifying the amount of RBCs at the outlets. The results suggest that the proposed MD 3 configuration was the most effective one for the desired application, due to the formation of a wider CFL. As a result, a minor amount of RBCs flow through the hyperbolic contraction at the third separation level of the device. Nevertheless, for all the proposed geometries, the existence of three separation levels shows that it is possible to achieve a highly efficient cell separation. If needed, such microdevices have the potential for further improvements by increasing the number of separation levels, aiming the total separation of blood cells from plasma.


Subject(s)
Lab-On-A-Chip Devices , Microfluidic Analytical Techniques , Cell Separation , Erythrocyte Count , Erythrocyte Deformability , Erythrocytes
4.
Micromachines (Basel) ; 10(10)2019 Sep 25.
Article in English | MEDLINE | ID: mdl-31557932

ABSTRACT

The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.

5.
J Funct Biomater ; 9(4)2018 Dec 04.
Article in English | MEDLINE | ID: mdl-30518160

ABSTRACT

Blood analogues have long been a topic of interest in biofluid mechanics due to the safety and ethical issues involved in the collection and handling of blood samples. Although the current blood analogue fluids can adequately mimic the rheological properties of blood from a macroscopic point of view, at the microscopic level blood analogues need further development and improvement. In this work, an innovative blood analogue containing giant unilamellar vesicles (GUVs) was developed to mimic the flow behavior of red blood cells (RBCs). A natural lipid mixture, soybean lecithin, was used for the GUVs preparation, and three different lipid concentrations were tested (1 × 10-3 M, 2 × 10-3 M and 4 × 10-3 M). GUV solutions were prepared by thin film hydration with a buffer, followed by extrusion. It was found that GUVs present diameters between 5 and 7 µm which are close to the size of human RBCs. Experimental flow studies of three different GUV solutions were performed in a hyperbolic-shaped microchannel in order to measure the GUVs deformability when subjected to a homogeneous extensional flow. The result of the deformation index (DI) of the GUVs was about 0.5, which is in good agreement with the human RBC's DI. Hence, the GUVs developed in this study are a promising way to mimic the mechanical properties of the RBCs and to further develop particulate blood analogues with flow properties closer to those of real blood.

6.
Biosensors (Basel) ; 8(4)2018 Dec 09.
Article in English | MEDLINE | ID: mdl-30544881

ABSTRACT

Microfluidic devices have been widely used as a valuable research tool for diagnostic applications. Particularly, they have been related to the successful detection of different diseases and conditions by assessing the mechanical properties of red blood cells (RBCs). Detecting deformability changes in the cells and being able to separate those cells may be a key factor in assuring the success of detection of some blood diseases with diagnostic devices. To detect and separate the chemically modified RBCs (mimicking disease-infected RBCs) from healthy RBCs, the present work proposes a microfluidic device comprising a sequence of pillars with different gaps and nine different outlets used to evaluate the efficiency of the device by measuring the optical absorption of the collected samples. This latter measurement technique was tested to distinguish between healthy RBCs and RBCs chemically modified with glutaraldehyde. The present study indicates that it was possible to detect a slight differences between the samples using an optical absorption spectrophotometric setup. Hence, the proposed microfluidic device has the potential to perform in one single step a partial passive separation of RBCs based on their deformability.


Subject(s)
Cell Separation/instrumentation , Erythrocytes/cytology , Microfluidic Analytical Techniques/instrumentation , Cell Size , Diagnosis, Differential , Erythrocyte Deformability , Female , Glutaral/chemistry , Humans , Lab-On-A-Chip Devices , Spectrophotometry
7.
Micromachines (Basel) ; 9(4)2018 Mar 27.
Article in English | MEDLINE | ID: mdl-30424085

ABSTRACT

Techniques, such as micropipette aspiration and optical tweezers, are widely used to measure cell mechanical properties, but are generally labor-intensive and time-consuming, typically involving a difficult process of manipulation. In the past two decades, a large number of microfluidic devices have been developed due to the advantages they offer over other techniques, including transparency for direct optical access, lower cost, reduced space and labor, precise control, and easy manipulation of a small volume of blood samples. This review presents recent advances in the development of microfluidic devices to evaluate the mechanical response of individual red blood cells (RBCs) and microbubbles flowing in constriction microchannels. Visualizations and measurements of the deformation of RBCs flowing through hyperbolic, smooth, and sudden-contraction microchannels were evaluated and compared. In particular, we show the potential of using hyperbolic-shaped microchannels to precisely control and assess small changes in RBC deformability in both physiological and pathological situations. Moreover, deformations of air microbubbles and droplets flowing through a microfluidic constriction were also compared with RBCs deformability.

8.
Micromachines (Basel) ; 9(8)2018 Aug 02.
Article in English | MEDLINE | ID: mdl-30424317

ABSTRACT

Malaria is one of the leading causes of death in underdeveloped regions. Thus, the development of rapid, efficient, and competitive diagnostic techniques is essential. This work reports a study of the deformability and velocity assessment of healthy and artificially impaired red blood cells (RBCs), with the purpose of potentially mimicking malaria effects, in narrow polydimethylsiloxane microchannels. To obtain impaired RBCs, their properties were modified by adding, to the RBCs, different concentrations of glucose, glutaraldehyde, or diamide, in order to increase the cells' rigidity. The effects of the RBCs' artificial stiffening were evaluated by combining image analysis techniques with microchannels with a contraction width of 8 µm, making it possible to measure the cells' deformability and velocity of both healthy and modified RBCs. The results showed that healthy RBCs naturally deform when they cross the contractions and rapidly recover their original shape. In contrast, for the modified samples with high concentration of chemicals, the same did not occur. Additionally, for all the tested modification methods, the results have shown a decrease in the RBCs' deformability and velocity as the cells' rigidity increases, when compared to the behavior of healthy RBCs samples. These results show the ability of the image analysis tools combined with microchannel contractions to obtain crucial information on the pathological blood phenomena in microcirculation. Particularly, it was possible to measure the deformability of the RBCs and their velocity, resulting in a velocity/deformability relation in the microchannel. This correlation shows great potential to relate the RBCs' behavior with the various stages of malaria, helping to establish the development of new diagnostic systems towards point-of-care devices.

9.
J Biomech ; 49(11): 2293-2298, 2016 07 26.
Article in English | MEDLINE | ID: mdl-26671221

ABSTRACT

The behavior of suspensions of individual blood cells, such as red blood cells (RBCs), flowing through microvessels and microfluidic systems depend strongly on the hematocrit (Hct), microvessel topology and cell properties. Although it is well known that blood rheological properties are temperature dependent, to the best of our knowledge no work has studied the role of the temperature on the RBCs dispersion. A powerful way to investigate this latter effect is through a high-speed video microscopy system, which provides detailed flow measurements of each individual RBC. Hence, the effect of temperature on the RBCs dispersion flowing through a 100µm glass capillary was examined by means of a confocal micro-PTV system. Hundreds of labeled RBCs were tracked at moderate Hct (12%) and at four different temperatures, i.e., 25°C, 32°C, 37°C and 42°C. The results yielded an enhancement of the RBCs diffusion as the temperature increases. Hence, our findings show that RBCs radial dispersion is temperature dependent and as a result the temperature should not be ignored in future blood flow studies. We believe that this finding is important for a better understanding of blood mass transport mechanisms under both physiological and pathological conditions.


Subject(s)
Erythrocytes/physiology , Microvessels/physiology , Temperature , Diffusion , Hematocrit , Hemodynamics , Hemorheology , Humans , Microfluidics , Microscopy, Video
10.
J Biomech ; 49(11): 2280-2292, 2016 07 26.
Article in English | MEDLINE | ID: mdl-26671220

ABSTRACT

One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made to develop low-cost alternatives for the fabrication of microstructures, avoiding the use of cleanroom facilities. Recently, low-cost techniques without cleanroom facilities that feature aspect ratios more than 20, for fabricating those SU-8 moulds have been gaining popularity among biomedical research community. In those techniques, Ultraviolet (UV) exposure equipment, commonly used in the Printed Circuit Board (PCB) industry, replaces the more expensive and less available Mask Aligner that has been used in the last 15 years for SU-8 patterning. Alternatively, non-lithographic low-cost techniques, due to their ability for large-scale production, have increased the interest of the industrial and research community to develop simple, rapid and low-cost microfluidic structures. These alternative techniques include Print and Peel methods (PAP), laserjet, solid ink, cutting plotters or micromilling, that use equipment available in almost all laboratories and offices. An example is the xurography technique that uses a cutting plotter machine and adhesive vinyl films to generate the master moulds to fabricate microfluidic channels. In this review, we present a selection of the most recent lithographic and non-lithographic low-cost techniques to fabricate microfluidic structures, focused on the features and limitations of each technique. Only microfabrication methods that do not require the use of cleanrooms are considered. Additionally, potential applications of these microfluidic devices in biomedical engineering are presented with some illustrative examples.


Subject(s)
Lab-On-A-Chip Devices , Microtechnology/methods , Biomedical Technology/economics , Biomedical Technology/instrumentation , Biomedical Technology/methods , Costs and Cost Analysis , Lab-On-A-Chip Devices/economics , Microfluidics/economics , Microfluidics/instrumentation , Microfluidics/methods
11.
Biomed Microdevices ; 17(6): 108, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26482154

ABSTRACT

Blood flow presents several interesting phenomena in microcirculation that can be used to develop microfluidic devices capable to promote blood cells separation and analysis in continuous flow. In the last decade there have been numerous microfluidic studies focused on the deformation of red blood cells (RBCs) flowing through geometries mimicking microvessels. In contrast, studies focusing on the deformation of white blood cells (WBCs) are scarce despite this phenomenon often happens in the microcirculation. In this work, we present a novel integrative microfluidic device able to perform continuous separation of a desired amount of blood cells, without clogging or jamming, and at the same time, capable to assess the deformation index (DI) of both WBCs and RBCs. To determine the DI of both WBCs and RBCs, a hyperbolic converging microchannel was used, as well as a suitable image analysis technique to measure the DIs of these blood cells along the regions of interest. The results show that the WBCs have a much lower deformability than RBCs when subjected to the same in vitro flow conditions, which is directly related to their cytoskeleton and nucleus contents. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to simultaneously separate and assess blood cells deformability.


Subject(s)
Erythrocyte Deformability , Erythrocytes/cytology , Lab-On-A-Chip Devices , Leukocytes/cytology , Microfluidic Analytical Techniques/instrumentation , Equipment Design , Humans , Image Processing, Computer-Assisted , Leukocyte Count