Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 619
Filter
1.
Am J Clin Pathol ; 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39024475

ABSTRACT

OBJECTIVES: Our objective was to maintain low interlaboratory variation and bias in international normalized ratio (INR) results following a network change in instrumentation and reagents, using a process of ongoing standardization and harmonization. METHODS: Network-wide standardization to new common instrument and reagent platforms followed by network-wide application of a simple novel process of verification of international sensitive index and mean normal prothrombin time values for each new lot of prothrombin time (PT) reagent that does not require use of World Health Organization reference thromboplastin or INR calibration/certified plasma. RESULTS: The network transitioned from mechanical hemostasis detection instruments with associated PT reagent (Diagnostica Stago; NeoPTimal) to optical detection (ACL TOPs) with associated PT reagent (Werfen; RecombiPlasTin 2G). Comparing 3 years of data for each situation, the network (n = 27 laboratories) maintained low INR variability and bias relative to general mechanical and optical groups and other laboratories. CONCLUSIONS: Harmonized support for patient management of vitamin K antagonists such as warfarin was continuously maintained in our geography, with potentially positive implications for other coagulation laboratories and geographies. For the United States in particular, paucity of US Food and Drug Administration-cleared INR certified plasmas potentially compromises INR test accuracy; our novel approach may provide workable alternatives for other laboratories/networks.

3.
Clin Chem Lab Med ; 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39008654

ABSTRACT

The healthcare systems are a prime target for cyber-attacks due to the sensitive nature of the information combined with the essential need for continuity of care. Medical laboratories are particularly vulnerable to cyber-attacks for a number of reasons, including the high level of information technology (IT), computerization and digitization. Based on reliable and widespread evidence that medical laboratories may be inadequately prepared for cyber-terrorism, a panel of experts of the Task Force Preparation of Labs for Emergencies (TF-PLE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has recognized the need to provide some general guidance that could help medical laboratories to be less vulnerable and better prepared for the dramatic circumstance of a disruptive cyber-attack, issuing a number of consensus recommendations, which are summarized and described in this opinion paper.

5.
8.
J Clin Med ; 13(12)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38930139

ABSTRACT

Viscoelastic testing is increasingly being used in clinical and research settings to assess hemostasis. Indeed, there are potential situations in which viscoelastic testing is reportedly superior to standard routine laboratory testing for hemostasis. We report the current testing platforms and terminology, as well as providing a concise narrative review of the published evidence to guide its use in various clinical settings. Notably, there is increasing evidence of the potential utility of viscoelastic testing for assessment of direct oral anticoagulants, and bleeding associated with chronic liver disease, orthotopic liver transplantation, cardiac surgery, trauma, obstetrics and pediatrics.

12.
Res Pract Thromb Haemost ; 8(3): 102385, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38623474

ABSTRACT

Lupus anticoagulant (LA) represents 1 of the laboratory criteria for classification of patients as having definite antiphospholipid syndrome (APS). The other 2 laboratory criteria are anticardiolipin antibodies and anti-beta2-glycoprotein I antibodies. At least 1 of these antiphospholipid antibody (aPL) tests need to be positive, with evidence of persistence, together with evidence of at least 1 clinical criterion for APS, before a patient can be classified as having definite APS. LA and other aPL assays are also important for diagnosis or exclusion of APS, as well as for risk stratification, with triple-positive patients carrying the greatest risk. Whereas LA is identified through "uncalibrated" clot-based assays, the other aPL assays (anticardiolipin and anti-beta2-glycoprotein I antibodies) represent immunological assays, identified using calibrated solid-phase methods. Because LA is identified using clot-based assays, it is subject to considerable preanalytical and analytical issues that challenge accurate detection or exclusion of LA. In this narrative review, we take a look at the good, the bad, and the ugly of LA testing, primarily focusing on the last 10 years. Although harmonization of LA testing as a result of International Society on Thrombosis and Haemostasis guidance documents and other international activities has led to improvements in LA detection, many challenges remain. In particular, several anticoagulants, especially direct oral anticoagulants and also vitamin K antagonists, given as therapy to treat the pathophysiological consequences of aPL, especially thrombosis, interfere with LA assays and can generate false-positive or false-negative LA findings. Overcoming these diagnostic errors will require a multifaceted approach with clinicians and laboratories working together.

13.
Int J Lab Hematol ; 46(4): 731-740, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38644463

ABSTRACT

INTRODUCTION: Direct oral anticoagulants (DOACs) reflect anticoagulation agents given to treat or prevent thrombosis, having largely replaced vitamin K antagonists (VKAs) such as warfarin. DOACs are given in fixed daily doses and generally do not need monitoring. However, there may be a variety of reasons that justify measurement of plasma DOAC levels in individual patients. METHODS: We report updated findings for DOAC testing in our geographic region, using recent data from the RCPAQAP, an international external quality assessment (EQA) program, currently with some 40-60 participants in each of the different DOAC (rivaroxaban, apixaban, dabigatran) modules, to assess laboratory performance in this area. Data has been assessed for the past 5 years (2019-2023 inclusive), with 20 samples each per DOAC. RESULTS: Data shows a limited repertoire of assays in use, and mostly consistency in reported numerical values when assessing proficiency samples. Available assays mostly comprised reagents from four manufacturing suppliers. There was good consistency across what participants identified as 'DOAC detected', but some variability when participants attempted to grade DOAC levels as low vs moderate vs high. Inter-laboratory/method coefficient of variation (CVs) were generally <15% for each DOAC, when present at >100 ng/mL. CONCLUSION: We hope our findings, reflecting on mostly consistent reporting of DOAC levels and interpretation provides reassurance for clinicians requesting these measurements, and helps support their implementation in regions where there is a paucity of test availability.


Subject(s)
Anticoagulants , Humans , Administration, Oral , Anticoagulants/administration & dosage , Blood Coagulation Tests/standards , Blood Coagulation Tests/methods , Hemostasis/drug effects , Rivaroxaban/blood , Pyridones/administration & dosage , Australasia , Dabigatran , Drug Monitoring/methods , Drug Monitoring/standards , Pyrazoles/therapeutic use , Pyrazoles/administration & dosage , Pyrazoles/blood
16.
Semin Thromb Hemost ; 50(4): 521-526, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38458227
17.
Res Pract Thromb Haemost ; 8(1): 102335, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38433976

ABSTRACT

A State of the Art lecture titled "D-dimer Diagnostics: Can I use any D-dimer assay? Bridging the Knowledge-to-Action gap" was presented at the International Society on Thrombosis and Haemostasis Congress in 2023, included in the session on the clinical impact of variability in commonly used coagulation assays. Here, we review the role of D-dimer, primarily in the outpatient diagnosis of patients with venous thromboembolism (VTE) when combined with clinical decision rules. We focus on the recent large management trials that have studied adjustments of VTE exclusion thresholds for D-dimer based on either prior clinical probability of VTE or patient age, and the resultant benefit of reduced imaging for VTE and improved diagnostic efficiency. In this context, we report on the significant variability between D-dimer results and the multiple D-dimer assays in use worldwide using data from international external quality assurance programs. This variability is particularly high at typical VTE exclusion thresholds. We discuss the potential clinical impact of D-dimer assay substitution on accuracy of diagnosis and risk stratification of patients with VTE. Finally, we summarize relevant new data on this topic presented during the 2023 International Society on Thrombosis and Haemostasis Congress and outline future priorities urgently needed to harmonize D-dimer results and reporting that will require international collaboration among multiple stakeholders with an overall goal to close this knowledge-to-action gap.

18.
J Med Biochem ; 43(1): 1-10, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38496022

ABSTRACT

The use of artificial intelligence (AI) has become widespread in many areas of science and medicine, including laboratory medicine. Although it seems obvious that the analytical and post-analytical phases could be the most important fields of application in laboratory medicine, a kaleidoscope of new opportunities has emerged to extend the benefits of AI to many manual labor-intensive activities belonging to the pre-analytical phase, which are inherently characterized by enhanced vulnerability and higher risk of errors. These potential applications involve increasing the appropriateness of test prescription (with computerized physician order entry or demand management tools), improved specimen collection (using active patient recognition, automated specimen labeling, vein recognition and blood collection assistance, along with automated blood drawing), more efficient sample transportation (facilitated by the use of pneumatic transport systems or drones, and monitored with smart blood tubes or data loggers), systematic evaluation of sample quality (by measuring serum indices, fill volume or for detecting sample clotting), as well as error detection and analysis. Therefore, this opinion paper aims to discuss the state-of-the-art and some future possibilities of AI in the preanalytical phase.

19.
Semin Thromb Hemost ; 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38458228

ABSTRACT

Due to their widespread use, testing for direct oral anticoagulants (DOACs) has become urgent in certain clinical situations. Screening based on widely available, rapid, and simple hemostasis assays such as prothrombin time, activated partial thromboplastin time, or even diluted Russel Viper venom time may provide sufficient evidence of "over-coagulation" and could be used "in small/peripheral/spoke laboratories" as an emergency strategy, but is not thought to be reliable for driving clinical decision making. Given their good correlation with plasma concentration, urine dipsticks may be considered a valuable alternative for emergency screening, although their performance is dependent on renal function, may vary depending on the time since the last urination, and there may be problems of interfacing with the laboratory/hospital information system. Separation methods based on liquid chromatography and mass spectrometry may be clinically questionable, since they measure the concentration rather than the actual inhibitory effect of DOACs, are relatively expensive, cumbersome and time consuming, and therefore seem unsuitable for most conditions requiring urgent clinical decision making. A proposed approach therefore involves establishing a network of routine clinical laboratories, designating a reference center where DOAC tests could be available 24/7, establishing a clear diagnostic care pathway for ordering the tests from the laboratory and standard operating procedures for performing them, the use of the diluted thrombin time for dabigatran and anti-FXa assays (drug-calibrated) for rivaroxaban, apixaban, and edoxaban, as well as providing expert advice throughout the testing process, from ordering to interpretation of results.

SELECTION OF CITATIONS
SEARCH DETAIL
...