Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
2.
Catheter Cardiovasc Interv ; 99(6): 1829-1838, 2022 05.
Article in English | MEDLINE | ID: mdl-35324050

ABSTRACT

OBJECTIVES: Report contemporary outcomes in patients included in the Mitragister registry and treated with transcatheter mitral valve implantation for failed surgical annuloplasty rings or deteriorated bioprosthesis. BACKGROUND: Midterm survival rates have been reported, but little is known about contemporary morbimortality endpoints. METHODS: The primary safety outcome was the technical success rate. The primary efficacy composite endpoint was a composite of cardiovascular mortality and heart failure hospitalizations. RESULTS: From 2016 to 2021, 102 patients (median age: 81 [74;84] years, 61% female, Euroscore II 11.0% [7.8;16.0]) undergoing valve-in-valve (ViV; n = 89) or valve-in-ring (ViR; n = 13) procedures were consecutively included. At baseline, ViR group patients had worse left ventricular ejection fraction (50% vs. 60%; p = 0.004) and more frequently severe regurgitation (46% vs. 15%; p = 0.014). The primary safety outcome was 95%: 77% and 98% in the ViR and ViV populations, respectively, (p = 0.014). At intermediate follow-up (6-12 months) clinical improvement was notable, 88% of the patients were in NYHA class ≤ II (vs. 25% at baseline; p < 0.001). At a mean follow-up of 17.1 ± 11.0 months, the primary efficacy composite reached 27%. By multivariate analysis, paravalvular leak (PVL) was the only independent predictor (hazard ratio: 2.39, 95% confidence interval: 1.08-5.29; p = 0.031) while ViR was not found statistically associated (p = 0.456). CONCLUSIONS: This study confirms the safety and efficacy of the mitral ViV procedure. ViR patients appear at higher risk of procedural complications. The presence of PVL could be associated with markedly worse midterm prognosis. Whatever the intervention, procedural strategies to reduce PVL incidence remain to be assessed to prevent latter adverse outcomes.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Aged, 80 and over , Bioprosthesis/adverse effects , Cardiac Catheterization/methods , Female , Heart Valve Prosthesis Implantation/methods , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prosthesis Failure , Registries , Stroke Volume , Treatment Outcome , Ventricular Function, Left
3.
JACC Cardiovasc Interv ; 14(15): 1704-1713, 2021 08 09.
Article in English | MEDLINE | ID: mdl-34274294

ABSTRACT

OBJECTIVES: Using French transcatheter aortic valve replacement (TAVR) registries linked with the nationwide administrative databases, the study compared the rates of long-term mortality, bleeding, and ischemic events after TAVR in patients requiring oral anticoagulation with direct oral anticoagulants (DOACs) or vitamin K antagonists (VKAs). BACKGROUND: The choice of optimal drug for anticoagulation after TAVR remains debated. METHODS: Data from the France-TAVI and FRANCE-2 registries were linked to the French national health single-payer claims database, from 2010 to 2017. Propensity score matching was used to reduce treatment-selection bias. Two primary endpoints were death from any cause (efficacy) and major bleeding (safety). RESULTS: A total of 24,581 patients who underwent TAVR were included and 8,962 (36.4%) were treated with OAC. Among anticoagulated patients, 2,180 (24.3%) were on DOACs. After propensity matching, at 3 years, mortality (hazard ratio [HR]: 1.37; 95% confidence interval [CI]: 1.12-1.67; P < 0.005) and major bleeding including hemorrhagic stroke (HR: 1.64; 95% CI: 1.17-2.29; P < 0.005) were lower in patients on DOACs compared with those on VKAs. The rates of ischemic stroke (HR: 1.32; 95% CI: 0.81-2.15; P = 0.27) and acute coronary syndrome (HR: 1.17; 95% CI: 0.68-1.99; P = 0.57) did not differ among groups. CONCLUSIONS: In these large multicenter French TAVR registries with an exhaustive clinical follow-up, the long-term mortality and major bleeding were lower with DOACs than VKAs at discharge. The present study supports preferential use of DOACs rather than VKAs in patients requiring oral anticoagulation therapy after TAVR.


Subject(s)
Atrial Fibrillation , Transcatheter Aortic Valve Replacement , Administration, Oral , Anticoagulants/adverse effects , Atrial Fibrillation/drug therapy , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Vitamin K
4.
J Invasive Cardiol ; 31(10): 300-306, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31567114

ABSTRACT

OBJECTIVES: To assess the safety and efficacy of a new simplified procedure for transfemoral (TF) transcatheter aortic valve replacement (TAVR): the FAST protocol. BACKGROUND: A minimalist approach for TF-TAVR has been reported. The goal of this simplified strategy is to reduce the rate of specific complications associated with general anesthesia, second vascular access, and use of temporary pacemaker, and to reduce the length of stay. METHODS: We retrospectively reviewed all TF-TAVR cases performed at our center between January 2015 and December 2017. The FAST strategy consisted of local anesthesia with conscious sedation, echocardiographically guided TF puncture for main vascular access, radial approach for secondary arterial access, and left ventricular guidewire rapid pacing. Patients were sorted according to the initial strategy (FAST vs standard). The primary outcome was an early safety composite outcome including all-cause mortality, all stroke, life-threatening bleeding, acute kidney injury, coronary artery obstruction, major vascular complication, and valve-related dysfunction. RESULTS: A total of 285 consecutive patients were included in the present analysis (76 FAST patients and 209 standard patients). There were no baseline differences between groups. Complete FAST procedure was feasible in 83.0% of cases and all FAST procedures were successful. The primary outcome was significantly lower in the FAST group (1.3% vs 14.3%; P<.001). The use of FAST protocol resulted in a reduction of major bleeding (1.3% vs 10.1%; P=.01), blood transfusion (2.6% vs 14.3%; P<.01), and vascular complications related to the secondary access (0.0% vs 5.3%; P=.04). The length of stay was also significantly lower in the FAST group (4.9 days vs 6.4 days; P<.01). CONCLUSIONS: FAST can be safely performed and is associated with lower rates of iatrogenic complications and a shorter length of stay.


Subject(s)
Aortic Valve Stenosis/surgery , Minimally Invasive Surgical Procedures/methods , Postoperative Complications/prevention & control , Aged, 80 and over , Cardiac Catheterization/methods , Feasibility Studies , Female , Femoral Artery , Follow-Up Studies , France/epidemiology , Humans , Incidence , Length of Stay/trends , Male , Postoperative Complications/epidemiology , Radial Artery , Retrospective Studies , Risk Factors , Survival Rate/trends , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
5.
Circulation ; 138(23): 2597-2607, 2018 12 04.
Article in English | MEDLINE | ID: mdl-30571260

ABSTRACT

BACKGROUND: The FRANCE-2 registry (French Aortic National Corevalve and Edwards) previously reported good early- and medium-term clinical and echocardiographic efficacy for transcatheter aortic valve replacement. We here report 5-year follow-up results from the registry. METHODS: The registry includes all consecutive patients undergoing transcatheter aortic valve replacement for severe aortic stenosis in France. Follow-up is scheduled at 30 days, 6 months, then annually from 1 to 5 years. Clinical events were defined according to the Valve Academic Research Consortium criteria, and hemodynamic structural valve deterioration (SVD) was defined according to the consensus statement by the European Association of Percutaneous Cardiovascular Interventions. RESULTS: Between January 2010 and January 2012, 4201 patients were enrolled in 34 centers. Five-year vital status was available for 95.5% of patients; 88.1% had clinical evaluation or died. Overall, at 5 years, all-cause mortality was 60.8% (n=2478; 95% CI, 59.3% to 62.3%). The majority of cardiovascular events occurred in the first month after valve implantation, and incidence remained low thereafter, at <2% per year up to 5 years, except for heart failure. The rate of heart failure was 14.3% at 1 year, then decreased over time to <5% per year. In cumulative incidence function, the rates of severe SVD and moderate/severe SVD at 5 years were 2.5% and 13.3%, respectively. Mortality did not differ between patients with or without severe SVD (hazard ratio, 0.71; 95% CI, 0.47-1.07; P=0.1). Finally, in the population of patients with severe SVD, 1 patient (1.7%) experienced a stroke, and 8 patients presented ≥1 heart failure event (13.3%). CONCLUSIONS: The 5-year follow-up results of the FRANCE-2 registry represent the largest long-term data set available in a high-risk population. In surviving patients, the low rate of clinical events and the low level of SVD after 1 year support the long-term efficacy of transcatheter aortic valve replacement in both types of transcatheter prosthesis featuring in the registry.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Equipment Failure , Female , Follow-Up Studies , Heart Failure/diagnosis , Heart Failure/epidemiology , Hemodynamics , Humans , Male , Proportional Hazards Models , Registries , Risk Factors , Stroke/diagnosis , Stroke/epidemiology , Survival Analysis , Time Factors , Treatment Outcome
6.
J Am Coll Cardiol ; 68(15): 1637-1647, 2016 10 11.
Article in English | MEDLINE | ID: mdl-27712776

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has revolutionized management of high-risk patients with severe aortic stenosis. However, survival and the incidence of severe complications have been assessed in relatively small populations and/or with limited follow-up. OBJECTIVES: This report details late clinical outcome and its determinants in the FRANCE-2 (FRench Aortic National CoreValve and Edwards) registry. METHODS: The FRANCE-2 registry prospectively included all TAVRs performed in France. Follow-up was scheduled at 30 days, at 6 months, and annually from 1 to 5 years. Standardized VARC (Valve Academic Research Consortium) outcome definitions were used. RESULTS: A total of 4,201 patients were enrolled between January 2010 and January 2012 in 34 centers. Approaches were transarterial (transfemoral 73%, transapical 18%, subclavian 6%, and transaortic or transcarotid 3%) or, in 18% of patients, transapical. Median follow-up was 3.8 years. Vital status was available for 97.2% of patients at 3 years. The 3-year all-cause mortality was 42.0% and cardiovascular mortality was 17.5%. In a multivariate model, predictors of 3-year all-cause mortality were male sex (p < 0.001), low body mass index, (p < 0.001), atrial fibrillation (p < 0.001), dialysis (p < 0.001), New York Heart Association functional class III or IV (p < 0.001), higher logistic EuroSCORE (p < 0.001), transapical or subclavian approach (p < 0.001 for both vs. transfemoral approach), need for permanent pacemaker implantation (p = 0.02), and post-implant periprosthetic aortic regurgitation grade ≥2 of 4 (p < 0.001). Severe events according to VARC criteria occurred mainly during the first month and subsequently in <2% of patients/year. Mean gradient, valve area, and residual aortic regurgitation were stable during follow-up. CONCLUSIONS: The FRANCE-2 registry represents the largest database available on late results of TAVR. Late mortality is largely related to noncardiac causes. Incidence rates of severe events are low after the first month. Valve performance remains stable over time.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Female , France , Humans , Male , Prospective Studies , Registries , Risk Assessment , Time Factors , Treatment Outcome
7.
N Engl J Med ; 366(18): 1705-15, 2012 May 03.
Article in English | MEDLINE | ID: mdl-22551129

ABSTRACT

BACKGROUND: Transcatheter aortic-valve implantation (TAVI) is an emerging intervention for the treatment of high-risk patients with severe aortic stenosis and coexisting illnesses. We report the results of a prospective multicenter study of the French national transcatheter aortic-valve implantation registry, FRANCE 2. METHODS: All TAVIs performed in France, as listed in the FRANCE 2 registry, were prospectively included in the study. The primary end point was death from any cause. RESULTS: A total of 3195 patients were enrolled between January 2010 and October 2011 at 34 centers. The mean (±SD) age was 82.7±7.2 years; 49% of the patients were women. All patients were highly symptomatic and were at high surgical risk for aortic-valve replacement. Edwards SAPIEN and Medtronic CoreValve devices were implanted in 66.9% and 33.1% of patients, respectively. Approaches were either transarterial (transfemoral, 74.6%; subclavian, 5.8%; and other, 1.8%) or transapical (17.8%). The procedural success rate was 96.9%. Rates of death at 30 days and 1 year were 9.7% and 24.0%, respectively. At 1 year, the incidence of stroke was 4.1%, and the incidence of periprosthetic aortic regurgitation was 64.5%. In a multivariate model, a higher logistic risk score on the European System for Cardiac Operative Risk Evaluation (EuroSCORE), New York Heart Association functional class III or IV symptoms, the use of a transapical TAVI approach, and a higher amount of periprosthetic regurgitation were significantly associated with reduced survival. CONCLUSIONS: This prospective registry study reflected real-life TAVI experience in high-risk elderly patients with aortic stenosis, in whom TAVI appeared to be a reasonable option. (Funded by Edwards Lifesciences and Medtronic.).


Subject(s)
Aortic Valve Stenosis/therapy , Cardiac Catheterization , Heart Valve Prosthesis Implantation/methods , Registries , Aged , Aged, 80 and over , Aortic Valve Stenosis/complications , Cardiac Catheterization/methods , Female , France/epidemiology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Hemorrhage/epidemiology , Hemorrhage/etiology , Humans , Incidence , Male , Multivariate Analysis , Prospective Studies , Stroke/epidemiology , Stroke/etiology
8.
Catheter Cardiovasc Interv ; 73(1): 44-7, 2009 Jan 01.
Article in English | MEDLINE | ID: mdl-19089936

ABSTRACT

OBJECTIVES: To assess safety and feasibility of using radial artery access for percutaneous coronary intervention (PCI) in patients on oral anticoagulation without interrupting therapy. BACKGROUND: The radial artery approach for PCI is intuitively attractive for patients receiving chronic oral anticoagulation with vitamin K antagonists (VKAs) but little data exist concerning feasibility or safety of this approach in this population. The main advantage of this strategy would be to avoid bridging therapy with heparin that increases risk of thrombotic and bleeding events. METHODS: In this prospective observational study, 50 consecutive patients referred for coronary angiography underwent PCI without interrupting oral anticoagulant therapy. The main outcome measures were bleeding and thrombotic complications. RESULTS: The indications for permanent oral anticoagulation were as follows: atrial fibrillation in 62%, mechanical prosthesis in 24%, and venous thromboembolism in 14%. Seventy-two percent were elective cases and 28% presented with acute coronary syndromes. PCI was performed with an INR range of 1.4-3.4 with mean of 2.2 +/- 0.6. Seventy-six percent of the patients were on dual antiplatelet therapy before the procedure. No thrombotic events or excess bleeding were observed at 1 month. Only one patient had a minor hemorrhage 8 days after procedure. CONCLUSIONS: This series suggests that for patients treated with VKAs, the use of radial artery access is feasible and safe for PCI on dual antiplatelet therapy without interrupting oral anticoagulant treatment.


Subject(s)
Angioplasty, Balloon, Coronary/methods , Anticoagulants/administration & dosage , Coronary Artery Disease/therapy , Radial Artery , Administration, Oral , Aged , Aged, 80 and over , Angioplasty, Balloon, Coronary/adverse effects , Anticoagulants/adverse effects , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Drug Administration Schedule , England , Feasibility Studies , Female , France , Hemorrhage/chemically induced , Humans , Male , Middle Aged , Platelet Aggregation Inhibitors/therapeutic use , Prospective Studies , Thrombosis/etiology , Time Factors , Treatment Outcome , Vitamin K/antagonists & inhibitors
SELECTION OF CITATIONS
SEARCH DETAIL
...