Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
2.
Comput Methods Programs Biomed ; 250: 108179, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38642427

ABSTRACT

BACKGROUND AND OBJECTIVES: One of the major problems related to type 1 diabetes (T1D) management is hypoglycemia, a condition characterized by low blood glucose levels and responsible for reduced quality of life and increased mortality. Fast-acting carbohydrates, also known as hypoglycemic treatments (HT), can counteract this event. In the literature, dosage and timing of HT are usually based on heuristic rules. In the present work, we propose an algorithm for mitigating hypoglycemia by suggesting preventive HT consumption, with dosages and timing determined by solving an optimization problem. METHODS: By leveraging integer programming and linear inequality constraints, the algorithm can bind the amount of suggested carbohydrates to standardized quantities (i.e., those available in "off-the-shelf" HT) and the minimal distance between consecutive suggestions (to reduce the nuisance for patients). RESULTS: The proposed method was tested in silico and compared with competitor algorithms using the UVa/Padova T1D simulator. At the cost of a slight increase of HT consumed per day, the proposed algorithm produces the lowest median and interquartile range of the time spent in hypoglycemia, with a statistically significant improvement over most competitor algorithms. Also, the average number of hypoglycemic events per day is reduced to 0 in median. CONCLUSIONS: Thanks to its positive performances and reduced computational burden, the proposed algorithm could be a candidate tool for integration in a DSS aimed at improving T1D management.


Subject(s)
Algorithms , Diabetes Mellitus, Type 1 , Hypoglycemia , Hypoglycemic Agents , Diabetes Mellitus, Type 1/drug therapy , Humans , Hypoglycemic Agents/administration & dosage , Hypoglycemic Agents/therapeutic use , Hypoglycemia/prevention & control , Computer Simulation , Blood Glucose/analysis
3.
J Mater Chem A Mater ; 11(24): 13039, 2023 Jun 20.
Article in English | MEDLINE | ID: mdl-37346741

ABSTRACT

[This corrects the article DOI: 10.1039/D2TA07686A.].

4.
J Mater Chem A Mater ; 11(24): 12746-12758, 2023 Jun 20.
Article in English | MEDLINE | ID: mdl-37346742

ABSTRACT

Since its verification in 2019, there have been numerous high-profile papers reporting improved efficiency of lithium-mediated electrochemical nitrogen reduction to make ammonia. However, the literature lacks any coherent investigation systematically linking bulk electrolyte properties to electrochemical performance and Solid Electrolyte Interphase (SEI) properties. In this study, we discover that the salt concentration has a remarkable effect on electrolyte stability: at concentrations of 0.6 M LiClO4 and above the electrode potential is stable for at least 12 hours at an applied current density of -2 mA cm-2 at ambient temperature and pressure. Conversely, at the lower concentrations explored in prior studies, the potential required to maintain a given N2 reduction current increased by 8 V within a period of 1 hour under the same conditions. The behaviour is linked more coordination of the salt anion and cation with increasing salt concentration in the electrolyte observed via Raman spectroscopy. Time of flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy reveal a more inorganic, and therefore more stable, SEI layer is formed with increasing salt concentration. A drop in faradaic efficiency for nitrogen reduction is seen at concentrations higher than 0.6 M LiClO4, which is attributed to a combination of a decrease in nitrogen solubility and diffusivity as well as increased SEI conductivity as measured by electrochemical impedance spectroscopy.

5.
Oper Dent ; 48(3): 294-303, 2023 May 01.
Article in English | MEDLINE | ID: mdl-36656317

ABSTRACT

This study aimed to compare the fracture toughness of molars with wide mesio-occlusal-distal (MOD) cavities restored with regular and flowable bulk-fill resin composite and a conventional resin composite after 250,000 mechanical cycles of chewing simulation. Thirty-two extracted mandibular third molars were selected and class II MOD cavities involving 2/3 of the intercuspal width and 4 mm depth were prepared. Teeth were divided into four groups based on resin composite type and insertion technique (n=8): (1) CT, unprepared teeth (control); (2) CV, conventional resin composite (Tetric N-Ceram, Ivoclar Vivadent) with incremental technique; (3) R-BF, regular bulk-fill resin composite (Tetric N-Ceram Bulk Fill, Ivoclar Vivadent) with a single increment; and (4) F-BF, flowable bulk-fill resin composite (Tetric N-Flow Bulk Fill, Ivoclar Vivadent) with a single increment, except for a 1-mm-thick layer at the occlusal surface, restored with conventional resin composite (Tetric N-Ceram). All specimens were evaluated to detect the presence and propagation of enamel cracks using a LED transilluminator before and after 250,000 mechanical cycles (SD Mechatronic GmbH). After a chewing simulation, they were subjected to a compressive force in a universal testing machine (DL-2000, EMIC) until fracture. The maximum fracture load of the specimens was measured (N) and the fracture patterns were classified based on the fracture site (above or below the cementoenamel junction [CEJ]). Data were statistically analyzed with one-way ANOVA. All specimens survived after 250,000 mechanical cycles, and no statistically significant differences among groups were observed regarding the fracture toughness (p<0.05). The fracture analysis demonstrated that failures below the CEJ were more common in CV (75%), while CT, R-BF, and F-BF showed this type of failure in 38%, 63%, and 63% of the specimens, respectively. The results of the crack analysis showed that the occurrence of new cracks and crack propagation was also higher in CV (33.3%), followed by R-BF, F-BF, and CT (14%, 14%, and 11% of the specimens, respectively). Teeth restored with regular and flowable bulk-fill composites showed similar fracture toughness after the chewing simulation compared to those restored with the conventional resin composite and unprepared teeth. Furthermore, teeth restored with both regular and flowable bulk-fill composites showed a lower incidence of enamel cracks and fractures below the CEJ compared to those restored with the conventional resin composite.


Subject(s)
Composite Resins , Mastication , Composite Resins/therapeutic use , Acrylic Resins , Polyurethanes , Molar , Materials Testing , Dental Restoration, Permanent/methods
6.
Comput Methods Programs Biomed ; 225: 107104, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36088892

ABSTRACT

BACKGROUND AND OBJECTIVE: The glucose clamp (GC) is an experimental technique for assessing several aspects of glucose metabolism. In these experiments, investigators face the non-trivial challenge of accurately adjusting the rate of intravenous glucose infusion to drive subjects' blood glucose (BG) concentration towards a desired plateau level. In this work we present Gluclas, an open-source software to support researchers in the modulation of glucose infusion rate (GIR) during GC experiments. METHODS: Gluclas uses a proportional-integrative-derivative controller to provide GIR suggestions based on BG measurements. The controller embeds an anti-wind-up scheme to account for actuator physical limits and suitable corrections of control action to accommodate for possible sampling jitter due to manual measurement and actuation. The software also provides a graphic user interface to increase its usability. A preliminary validation of the controller is performed for different clamp scenarios (hyperglycemic, euglycemic, hypoglycemic) on a simulator of glucose metabolism in healthy subjects, which also includes models of measurement error and sampling delay for increased realism. In silico trials are performed on 50 virtual subjects. We also report the results of the first in-vivo application of the software in three subjects undergoing a hypoglycemic clamp. RESULTS: In silico, during the plateau period, the coefficient of variation (CV) is in median below 5% for every protocol, with 5% being considered the threshold for sufficient quality. In terms of median [5th percentile, 95th percentile], average BG level during the plateau period is 12.18 [11.58 - 12.53] mmol/l in the hyperglycemic clamp (target: 12.4 mmol/), 4.92 [4.51 - 5.14] mmol/l in the euglycemic clamp (target: 5.5 mmol/) and 2.38 [2.33 - 2.64] in the hypoglycemic clamp (target: 2.5 mmol/). Results in vivo are consistent with those obtained in silico during the plateau period: average BG levels are between 2.56 and 2.68 mmol/l (target: 2.5 mmol/l); CV is below 5% for all three experiments. CONCLUSIONS: Gluclas offered satisfactory control for tested GC protocols. Although its safety and efficacy need to be further validated in vivo, this preliminary validation suggest that Gluclas offers a reliable and non-expensive solution for reducing investigator bias and improving the quality of GC experiments.


Subject(s)
Blood Glucose , Glucose , Blood Glucose/metabolism , Computers , Glucose Clamp Technique , Humans , Hypoglycemic Agents , Insulin , Software
7.
Comput Methods Programs Biomed ; 221: 106862, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35597208

ABSTRACT

BACKGROUND AND OBJECTIVE: In type 1 diabetes (T1D) research, in-silico clinical trials (ISCTs) notably facilitate the design/testing of new therapies. Published simulation tools embed mathematical models of blood glucose (BG) and insulin dynamics, continuous glucose monitoring (CGM) sensors, and insulin treatments, but lack a realistic description of some aspects of patient lifestyle impacting on glucose control. Specifically, to effectively simulate insulin correction boluses, required to treat post-meal hyperglycemia (BG > 180 mg/dL), the timing of the bolus may be influenced by subjects' behavioral attitudes. In this work, we develop an easily interpretable model of the variability of correction bolus timing observed in real data, and embed it into a popular simulation tool for ISCTs. METHODS: Using data collected in 196 adults with T1D monitored in free-living conditions, we trained a decision tree (DT) model to classify whether a correction bolus is injected in a future time window, based on predictors collected back in time, related to CGM data, previous insulin boluses and subject's characteristics. The performance was compared to that of a logistic regression classifier with LASSO regularization (LC), trained on the same dataset. After validation, the DT was embedded within a popular T1D simulation tool and an ISCT was performed to compare the simulated correction boluses against those observed in a subset of data not used for model training. RESULTS: The DT provided better classification performance (accuracy: 0.792, sensitivity: 0.430, specificity: 0.878, precision: 0.455) than the LC and presented good interpretability. The most predictive features were related to CGM (and its temporal variations), time since the last insulin bolus, and time of the day. The correction boluses simulated by the DT, after implementation in the simulation tool, showed a good agreement with real-world data. CONCLUSIONS: The DT developed in this work represents a simple set of rules to mimic the same timing of correction boluses observed on real data. The inclusion of the model in simulation tools allows investigators to perform ISCTs that more realistically represent the patient behavior in taking correction boluses and the post-prandial BG response. In the future, more complex models can be investigated.


Subject(s)
Diabetes Mellitus, Type 1 , Insulin , Adult , Blood Glucose , Blood Glucose Self-Monitoring , Decision Trees , Diabetes Mellitus, Type 1/drug therapy , Humans , Hypoglycemic Agents/therapeutic use , Insulin Infusion Systems
8.
Comput Methods Programs Biomed ; 219: 106736, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35338888

ABSTRACT

BACKGROUND AND OBJECTIVE: Hybrid automated insulin delivery systems rely on carbohydrate counting to improve postprandial control in type 1 diabetes. However, this is an extra burden on subjects, and it introduces a source of potential errors that could impact control performances. In fact, carbohydrates estimation is challenging, prone to errors, and it is known that subjects sometimes struggle to adhere to this requirement, forgetting to perform this task. A possible solution is the use of automated meal detection algorithms. In this work, we extended a super-twisting-based meal detector suggested in the literature and assessed it on real-life data. METHODS: To reduce the false detections in the original meal detector, we implemented an implicit discretization of the super-twisting and replaced the Euler approximation of the glucose derivative with a Kalman filter. The modified meal detector is retrospectively evaluated in a challenging real-life dataset corresponding to a 2-week trial with 30 subjects using sensor-augmented pump control. The assessment includes an analysis of the nature and riskiness of false detections. RESULTS: The proposed algorithm achieved a recall of 70 [13] % (median [interquartile range]), a precision of 73 [26] %, and had 1.4 [1.4] false positives-per-day. False positives were related to rising glucose conditions, whereas false negatives occurred after calibrations, missing samples, or hypoglycemia treatments. CONCLUSIONS: The proposed algorithm achieves encouraging performance. Although false positives and false negatives were not avoided, they are related to situations with a low risk of hypoglycemia and hyperglycemia, respectively.


Subject(s)
Diabetes Mellitus, Type 1 , Hypoglycemia , Pancreas, Artificial , Algorithms , Blood Glucose/analysis , Diabetes Mellitus, Type 1/drug therapy , Glucose , Humans , Hypoglycemia/prevention & control , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin Infusion Systems , Retrospective Studies
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 677-680, 2021 11.
Article in English | MEDLINE | ID: mdl-34891383

ABSTRACT

Post-prandial hypoglycemia occurs 2-5 hours after food intake, in not only insulin-treated patients with diabetes but also other metabolic disorders. For example, postprandial hypoglycemia is an increasingly recognized late metabolic complication of bariatric surgery (also known as PBH), particularly gastric bypass. Underlying mechanisms remain incompletely understood to date. Besides excessive insulin exposure, impaired counter-regulation may be a further pathophysiological feature. To test this hypothesis, we need standardized postprandial hypoglycemic clamp procedures in affected and unaffected individuals allowing to reach identical predefined postprandial hypoglycemic trajectories. Generally, in these experiments, clinical investigators manually adjust glucose infusion rate (GIR) to clamp blood glucose (BG) to a target hypoglycemic value. Nevertheless, reaching the desired target by manual adjustment may be challenging and possible glycemic undershoots when approaching hypoglycemia can be a safety concern for patients. In this study, we developed a PID algorithm to assist clinical investigators in adjusting GIR to reach the predefined trajectory and hypoglycemic target. The algorithm is developed in a manual mode to permit the clinical investigator to interfere. We test the controller in silico by simulating glucose-insulin dynamics in PBH and healthy nonsurgical individuals. Different scenarios are designed to test the robustness of the algorithm to different sources of variability and to errors, e.g. outliers in the BG measurements, sampling delays or missed measurements. The results prove that the PID algorithm is capable of accurately and safely reaching the target BG level, on both healthy and PBH subjects, with a median deviation from reference of 2.8% and 2.4% respectively.Clinical relevance- This control algorithm enables standardized, accurate and safe postprandial hypoglycemic clamps, as evidenced in silico in PBH patients and controls.


Subject(s)
Hypoglycemia , Hypoglycemic Agents , Algorithms , Blood Glucose , Humans , Hypoglycemia/chemically induced , Hypoglycemic Agents/therapeutic use , Postprandial Period
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1435-1438, 2021 11.
Article in English | MEDLINE | ID: mdl-34891555

ABSTRACT

In diabetes management, the fraction of time spent with glucose concentration within the physiological range of [70-180] mg/dL, namely time in range (TIR) is often computed by clinicians to assess glycemic control using a continuous glucose monitoring sensor. However, a sufficiently long monitoring period is required to reliably estimate this index. A mathematical equation derived by our group provides the minimum trial duration granting a desired uncertainty around the estimated TIR. The equation involves two parameters, pr and α, related to the population under analysis, which should be set based on the clinician's experience. In this work, we evaluated the sensitivity of the formula to the parameters.Considering two independent datasets, we predicted the uncertainty of TIR estimate for a population, using the parameters of the formula estimated for a different population. We also stressed the robustness of the formula by testing wider ranges of parameters, thus assessing the impact of large errors in the parameters' estimates.Plausible errors on the α estimate impact very slightly on the prediction (relative discrepancy < 5%), thus we suggest using a fixed value for α independently on the population being analyzed. Instead, pr should be adjusted to the TIR expected in the population, considering that errors around 20% result in a relative discrepancy of ~10%.In conclusion, the proposed formula is sufficiently robust to parameters setting and can be used by investigators to determine a suitable duration of the study.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1 , Blood Glucose , Glycemic Control , Humans , Time Factors
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 5502-5505, 2020 07.
Article in English | MEDLINE | ID: mdl-33019225

ABSTRACT

Type 1 diabetes (T1D) therapy requires multiple daily insulin injections to compensate the lack of endogenous insulin production due to ß-cells destruction. An empirical standard formula (SF) is commonly used for such a task. Unfortunately, SF does not include information on glucose dynamics, e.g. the glucose rate-of-change (ROC) provided by continuous glucose monitoring (CGM) sensor. Hence, SF can sometimes lead to under/overestimations that can cause critical hypo/hyperglycemic episodes during/after the meal. Recently, to overcome this limitation, we proposed new linear regression models, integrating ROC information and personalized features. Despite the first encouraging results, the nonlinear nature of the problem calls for the application of nonlinear models. In this work, random forest (RF) and gradient boosting tree (GBT), nonlinear machine learning methodologies, were investigated. A dataset of 100 virtual subjects, opportunely divided into training and testing sets, was used. For each individual, a single-meal scenario with different meal conditions (preprandial ROC, BG and meal amounts) was simulated. The assessment was performed both in terms of accuracy in estimating the optimal bolus and glycemic control. Results were compared to the best performing linear model previously developed. The two tree-based models proposed lead to a statistically significant improvement of glycemic control compared to the linear approach, reducing the time spent in hypoglycemia (from 32.49% to 27.57-25.20% for RF and GBT, respectively). These results represent a preliminary step to prove that nonlinear machine learning techniques can improve the estimation of insulin bolus in T1D therapy. Particularly, RF and GBT were shown to outperform the previously linear models proposed.Clinical Relevance- Insulin bolus estimation with nonlinear machine learning techniques reduces the risk of adverse events in T1D therapy.


Subject(s)
Diabetes Mellitus, Type 1 , Insulin , Blood Glucose , Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1/drug therapy , Humans , Hypoglycemic Agents , Machine Learning , Nonlinear Dynamics
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 3910-3913, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30441215

ABSTRACT

In this paper we consider the problem of predicting future values of glucose in type-1 diabetes. In particular, we investigate the benefit of including physical activity, measured by an off-the-shelf wearable device, to other physiologic signals frequently used to predict blood-glucose concentration, namely injected insulin, carbohydrates intake, and past glucose samples measured by a Continuous Glucose Monitoring (CGM) sensor. Derivation of individualized predictors is crucial to cope with the wide inter- and intra-subject variability: learning and updating patient-specific models of the glucose-insulin system and using them to design personalized control actions has the potential to improve substantially patients' quality oflife. On data collected by 6 subjects for 5 days, we identify a black-box liner model that uses insulin and meal as inputs and glucose as output. Prediction Error Method (PEM) is used for parameter estimation. The personalized model is employed to derive patient-tailored predictors. This procedure is then repeated using a further physiological input, accounting for physical activity. The prediction accuracy of the two models, including or not physical activity, was compared on the basis of two metrics commonly used in system identification, namely Coefficient of Determination (COD) and Root Mean Squared Error. The models identified with physical activity have better performance, increasing the 3-hr prediction COD by mean ± standard deviation of 18.5% ± 30.1%.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1 , Blood Glucose , Exercise , Humans , Insulin , Insulin Infusion Systems
13.
J Telemed Telecare ; 24(3): 230-237, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28345384

ABSTRACT

Introduction In the past years, we developed a telemonitoring service for young patients affected by Type 1 Diabetes. The service provides data to the clinical staff and offers an important tool to the parents, that are able to oversee in real time their children. The aim of this work was to analyze the parents' perceived usefulness of the service. Methods The service was tested by the parents of 31 children enrolled in a seven-day clinical trial during a summer camp. To study the parents' perception we proposed and analyzed two questionnaires. A baseline questionnaire focused on the daily management and implications of their children's diabetes, while a post-study one measured the perceived benefits of telemonitoring. Questionnaires also included free text comment spaces. Results Analysis of the baseline questionnaires underlined the parents' suffering and fatigue: 51% of total responses showed a negative tendency and the mean value of the perceived quality of life was 64.13 in a 0-100 scale. In the post-study questionnaires about half of the parents believed in a possible improvement adopting telemonitoring. Moreover, the foreseen improvement in quality of life was significant, increasing from 64.13 to 78.39 ( p-value = 0.0001). The analysis of free text comments highlighted an improvement in mood, and parents' commitment was also proved by their willingness to pay for the service (median = 200 euro/year). Discussion A high number of parents appreciated the telemonitoring service and were confident that it could improve communication with physicians as well as the family's own peace of mind.


Subject(s)
Caregivers/psychology , Diabetes Mellitus, Type 1/therapy , Parents/psychology , Telemedicine/methods , Attitude to Health , Child , Child, Preschool , Disease Management , Female , Humans , Male , Quality of Life/psychology , Surveys and Questionnaires
14.
Diabet Med ; 34(2): 262-271, 2017 02.
Article in English | MEDLINE | ID: mdl-27696520

ABSTRACT

AIM: To assess the impact on fear of hypoglycaemia and treatment satisfaction with an artificial pancreas system used for 2 consecutive months, as well as participant acceptance of the artificial pancreas system. METHODS: In a randomized crossover trial patient-related outcomes associated with an evening-and-night artificial pancreas and sensor-augmented pump therapy were compared. Both intervention periods lasted 8 weeks. The artificial pancreas acceptance questionnaire (range 0-90, higher scores better), Hypoglycaemia Fear Survey II (range 0-72, higher scores worse) and Diabetes Treatment Satisfaction Questionnaire (range 0-36, higher scores better) were completed by 32 participants. Semi-structured interviews were conducted after study completion in a subset of six participants. Outcomes were compared using a repeated-measures anova model or paired t-test when appropriate. RESULTS: The total artificial pancreas acceptance questionnaire score at the end of the artificial pancreas period was 69.1 (sd 14.7; 95% CI 63.5, 74.7), indicating a positive attitude towards the artificial pancreas. No significant differences were found among the scores at baseline, end of sensor-augmented pump therapy period or end of the artificial pancreas period with regard to fear of hypoglycaemia [28.2 (sd 17.5), 23.5 (sd 16.6) and 23.5 (sd 16.7), respectively; P = 0.099] or diabetes treatment satisfaction [29.0 (sd 3.9), 28.2 (sd 5.2) and 28.0 (sd 7.1), respectively; P = 0.43]. Themes frequently mentioned in the interviews were 'positive effects at work', 'improved blood glucose', 'fewer worries about blood glucose', but also 'frequent alarms', 'technological issues' and 'demand for an all-in-one device'. CONCLUSIONS: The psychological outcomes of artificial pancreas and sensor-augmented pump therapy were similar. Current artificial pancreas technology is promising but user concerns should be taken into account to ensure utility of these systems.


Subject(s)
Diabetes Mellitus, Type 1/drug therapy , Fear/psychology , Hypoglycemia/psychology , Hypoglycemic Agents/administration & dosage , Insulin Infusion Systems , Insulin/administration & dosage , Pancreas, Artificial , Patient Satisfaction , Adult , Blood Glucose/metabolism , Cross-Over Studies , Diabetes Mellitus, Type 1/metabolism , Female , Humans , Hypoglycemia/chemically induced , Hypoglycemic Agents/adverse effects , Insulin/adverse effects , Male , Middle Aged , Surveys and Questionnaires
15.
Diabetes Obes Metab ; 17(5): 468-76, 2015 May.
Article in English | MEDLINE | ID: mdl-25600304

ABSTRACT

AIMS: To test in an outpatient setting the safety and efficacy of continuous subcutaneous insulin infusion (CSII) driven by a modular model predictive control (MMPC) algorithm informed by continuous glucose monitoring (CGM) measurement. METHODS: 13 patients affected by type 1 diabetes participated to a non-randomized outpatient 42-h experiment that included two evening meals and overnight periods (in short, dinner & night periods). CSII was patient-driven during dinner & night period 1 and MMPC-driven during dinner&night period 2. The study was conducted in hotels, where patients could move around freely. A CGM system (G4 Platinum; Dexcom Inc., San Diego, CA, USA) and insulin pump (AccuChek Combo; Roche Diagnostics, Mannheim, Germany) were connected wirelessly to a smartphone-based platform (DiAs, Diabetes Assistant; University of Virginia, Charlottesville, VA, USA) during both periods. RESULTS: A significantly lower percentage of time spent with glucose levels <3.9 mmol/l was achieved in period 2 compared with period 1: 1.96 ± 4.56% vs 12.76 ± 15.84% (mean ± standard deviation, p < 0.01), together with a greater percentage of time spent in the 3.9-10 mmol/l target range: 83.56 ± 14.02% vs 62.43 ± 29.03% (p = 0.04). In addition, restricting the analysis to the overnight phases, a lower percentage of time spent with glucose levels <3.9 mmol/l (1.92 ± 4.89% vs 12.7 ± 19.75%; p = 0.03) was combined with a greater percentage of time spent in 3.9-10 mmol/l target range in period 2 compared with period 1 (92.16 ± 8.03% vs 63.97 ± 2.73%; p = 0.01). Average glucose levels were similar during both periods. CONCLUSIONS: The results suggest that MMPC managed by a wearable system is safe and effective during evening meal and overnight. Its sustained use during this period is currently being tested in an ongoing randomized 2-month study.


Subject(s)
Blood Glucose/analysis , Diabetes Mellitus, Type 1/drug therapy , Hypoglycemia/drug therapy , Hypoglycemic Agents/administration & dosage , Insulin Infusion Systems , Insulin/administration & dosage , Pancreas, Artificial , Adult , Aged , Algorithms , Ambulatory Care , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/blood , Drug Chronotherapy , Female , Humans , Hypoglycemia/blood , Male , Meals , Middle Aged , Time Factors , Treatment Outcome
16.
Neotrop Entomol ; 42(4): 431-5, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23949865

ABSTRACT

The resistance of triatomines to pyrethroids has been reported in several Latin American countries, including Brazil, indicating the need for the development of new approaches for the control of vectors of the Chagas disease. In here, we evaluated the insecticidal potential of the essential oil of Eucalyptus urograndis (Myrtaceae) against unsexed third and fourth instars of Rhodnius neglectus Lent (Hemiptera: Reduviidae) in topical application, fumigation, surface contact, and repellency . The insecticidal activity of the essential oil tested was detected by topical application (LD50 = 0.1731 µL/insect and LD99 = 0.2948 µL/insect for 24 h), fumigation (LC50 = 0.021 mL/mL air and LC99 = 0.1525 mL/mL air for 24 h) and surface contact (LC50 = 0.7073 µL/cm(2) and LC99 = 4.59 µL/cm(2) for 24 h). Mortality observed after 48-72-h exposure was very high and did not allow for any adjustment of the mortality curve. In the repellency assay, an effect was observed on 80% of tested nymphs. However, no repellency was observed after 24 h of exposure. Eucalyptus urograndis essential oil has a high insecticidal and repellent potential for R. neglectus nymphs, whether serving as a molecular model for new substances or as an alternative for the control of these insects.


Subject(s)
Eucalyptus , Insecticides , Oils, Volatile/pharmacology , Reduviidae/drug effects , Animals , Drug Evaluation , Time Factors
17.
IEEE Trans Biomed Eng ; 59(11): 2986-99, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22481809

ABSTRACT

Modularity plays a key role in many engineering systems, allowing for plug-and-play integration of components, enhancing flexibility and adaptability, and facilitating standardization. In the control of diabetes, i.e., the so-called "artificial pancreas," modularity allows for the step-wise introduction of (and regulatory approval for) algorithmic components, starting with subsystems for assured patient safety and followed by higher layer components that serve to modify the patient's basal rate in real time. In this paper, we introduce a three-layer modular architecture for the control of diabetes, consisting in a sensor/pump interface module (IM), a continuous safety module (CSM), and a real-time control module (RTCM), which separates the functions of insulin recommendation (postmeal insulin for mitigating hyperglycemia) and safety (prevention of hypoglycemia). In addition, we provide details of instances of all three layers of the architecture: the APS© serving as the IM, the safety supervision module (SSM) serving as the CSM, and the range correction module (RCM) serving as the RTCM. We evaluate the performance of the integrated system via in silico preclinical trials, demonstrating 1) the ability of the SSM to reduce the incidence of hypoglycemia under nonideal operating conditions and 2) the ability of the RCM to reduce glycemic variability.


Subject(s)
Diabetes Mellitus, Type 1/therapy , Insulin Infusion Systems , Monitoring, Ambulatory/methods , Pancreas, Artificial , Signal Processing, Computer-Assisted , Adult , Biomedical Engineering , Blood Glucose/physiology , Computer Simulation , Diabetes Mellitus, Type 1/blood , Humans , Insulin/administration & dosage , Monitoring, Ambulatory/instrumentation
18.
Braz J Biol ; 71(1 Suppl 1): 291-5, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21537602

ABSTRACT

The purpose of this study was to evaluate the integrity of two forest fragments in Rio Negro Pantanal sub-region, using coleopterans as environmental indicators. The study was carried out at Santa Emilia Farm in the Rio Negro sub-region, municipality of Aquidauana, Mato Grosso do Sul (19º 30' 18'' S and 55° 36' 45'' W). Two sites were selected, locally denominated as "cordilheiras" (narrow and elongated strands of elevated soil), one with low degree of anthropic disturbance (CL) and the other, currently undergoing restoration process (TD). The sampling sites were determined using a GPS device. Ten pit-fall traps containing water and detergent were used for the specimens sampling, which were screened and identified. Abundance, richness, diversity and similarity were determined. Abundance was higher for CL (n = 277) than for TD (n = 251). The same was observed for the diversity indices, CL showed H' = 2.83 bit.individual⁻¹ and TD = 2.48 bit.individual⁻¹, confirming the interferences made for abundance. Specimens of ten families were captured in CL area and seven families in TD area, indicating higher richness in CL, when compared to TD. The linear correlation coefficient (p > 0.05) indicates that both areas are significantly different, showing similarity value of 66.7%. The data show that the structure and disturbance degree in the environment integrity influence the composition of beetles fauna, causing the increase of abundance, richness and diversity in anthropogenic environments undergoing the early stage of regeneration.


Subject(s)
Biodiversity , Coleoptera/classification , Animals , Brazil , Population Density , Trees
19.
Braz. j. biol ; 71(1)Feb. 2011.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1468083

ABSTRACT

The purpose of this study was to evaluate the integrity of two forest fragments in Rio Negro Pantanal sub-region, using coleopterans as environmental indicators. The study was carried out at Santa Emilia Farm in the Rio Negro sub-region, municipality of Aquidauana, Mato Grosso do Sul (19º 30' 18'' S and 55° 36' 45'' W). Two sites were selected, locally denominated as "cordilheiras" (narrow and elongated strands of elevated soil), one with low degree of anthropic disturbance (CL) and the other, currently undergoing restoration process (TD). The sampling sites were determined using a GPS device. Ten pit-fall traps containing water and detergent were used for the specimens sampling, which were screened and identified. Abundance, richness, diversity and similarity were determined. Abundance was higher for CL (n = 277) than for TD (n = 251). The same was observed for the diversity indices, CL showed H' = 2.83 bit.individual-1 and TD = 2.48 bit.individual-1, confirming the interferences made for abundance. Specimens of ten families were captured in CL area and seven families in TD area, indicating higher richness in CL, when compared to TD. The linear correlation coefficient (p > 0.05) indicates that both areas are significantly different, showing similarity value of 66.7%. The data show that the structure and disturbance degree in the environment integrity influence the composition of beetles fauna, causing the increase of abundance, richness and diversity in anthropogenic environments undergoing the early stage of regeneration.


Este trabalho avalia a integridade de dois fragmentos de floresta da sub-região do Rio Negro do Pantanal, utilizando coleópteros como indicadores. O estudo foi conduzido na Fazenda Santa Emília, na sub-região do Rio Negro, município de Aquidauana, Estado de Mato Grosso do Sul (19º 30' 18'' S e 55° 36' 45'' W). Dois estreitos fragmentos de floresta (localmente conhecida com cordilheira), situados em terrenos um pouco mais elevados, um com baixo grau de perturbação antrópica (CL) e o outro em processo de restauração (TD). Os sítios de amostragem foram marcados com GPS. Dez armadilhas de queda contendo água e detergente foram utilizadas. Abundância, riqueza de espécie, diversidade e similaridade foram determinadas. Abundância foi maior para CL (n = 277) do que para TD (n = 251). A mesma tendência foi observada para índices de diversidade, CL com 2,83 e TD com 2,48. Indivíduos de dez famílias foram capturados na área CL e de sete famílias na área TD, indicando mais alta riqueza em CL. O coeficiente de correlação linear (p > 0,05) indica que ambas as áreas são significantemente diferentes, com valor de similaridade de 66,7%. Os dados mostram que o grau de perturbação e estrutura da integridade ambiental influencia a composição da fauna de besouros, causando o aumento em abundância, riqueza e diversidade nos dois fragmentos estudados.

20.
Eur J Epidemiol ; 19(9): 885-90, 2004.
Article in English | MEDLINE | ID: mdl-15499899

ABSTRACT

The results of the epidemiological and virological surveillance of influenza performed during the 1999/2000, 2000/2001 and 2001/2002 seasons in the northeastern Italy were presented and the relationship between age-specific morbidity rates and circulating strains were discussed.The epidemiological findings pointed out a change in age distribution. During the 1999/2000 season, characterized by a circulation of viruses antigenically close to the vaccine strain, a similar incidence rate in the 0-14 and 15-64-year-old groups was observed, while during the 2001/ 2002 winter the virus infected mostly children. During 2001/2002 season, B type viruses predominated with at least three distinguishable molecular variants. In particular, B/Victoria/2/87-like viruses re-emerged after more than a decade, and the antibodies elicited by the vaccine strain and by the strains circulating in previous seasons were poor or not protecting. The accumulation of susceptible subjects in young age group during the 1990s, due to the lack of circulation of B/Victoria/2/87-like viruses, was responsible for the unusual morbidity in the 0-14 year group. No circulation of B/Victoria/2/87-like viruses was observed in > 64-year-old group during 2001/2002 epidemic, probably due to a long-lasting immunity against viruses belonging to this lineage.


Subject(s)
Influenza B virus/isolation & purification , Influenza, Human/epidemiology , Sentinel Surveillance , Adolescent , Adult , Age Distribution , Aged , Child , Child, Preschool , Disease Outbreaks , Hemagglutination Inhibition Tests , Humans , Incidence , Infant , Influenza B virus/pathogenicity , Influenza, Human/virology , Italy/epidemiology , Middle Aged , Nasal Mucosa/virology
SELECTION OF CITATIONS
SEARCH DETAIL
...