Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
AAPS J ; 26(3): 61, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38750400

ABSTRACT

The aim of this study was to investigate the in-use compatibility of eight commercially available closed system transfer device brands (CSTDs) with a formulated model antibody drug conjugate (ADC). Overall, in-use simulated dosing preparation applying the CSTD systems investigated raised concerns for several product quality attributes. The incompatibilities observed were mainly associated with increased visible and subvisible particles formation as well as significant changes in holdup volumes. Visible and subvisible particles contained heterogeneous mixtures of particle classes, with the majority of subvisible particles associated with silicone oil leaching from CSTD systems during simulated dose preparation upon contact with the ADC formulation. These observations demonstrate that CSTD use may adversely impact product quality and delivered dose which could potentially lead to safety and efficacy concerns during administration. Other product quality attributes measured including turbidity, color, ADC recovery, and purity by size exclusion HPLC, did not show relevant changes. It is therefore strongly recommended to test and screen the compatibility of CSTDs with the respective ADC, in a representative in-use simulated administration setting, during early CMC development, i.e., well before the start of clinical studies, to include information about compatibility and to ensure that the CSTD listed in the manuals of preparation for clinical handling has been thoroughly assessed before human use.


Subject(s)
Immunoconjugates , Immunoconjugates/chemistry , Immunoconjugates/administration & dosage , Drug Compounding/methods , Chemistry, Pharmaceutical/methods , Particle Size
2.
Pharm Res ; 37(4): 81, 2020 Apr 09.
Article in English | MEDLINE | ID: mdl-32274594

ABSTRACT

PURPOSE: Health care professionals can be exposed to hazardous drugs such as cytostatics during preparation of drugs for administration. Closed sytem transfer devices (CSTDs) were introduced to provide protection for healthcare professional against unintended exposure to hazardous drugs. The interest in CSTDs has significantly increased after USP <800> monograph was issued. The majority of the studies published so far on CSTDs have focused on their "containment" function. However, other important attributes for CSTDs with potential importance for product quality impact are not yet fully evaluated. METHODS: In the current study, we evaluated four sytems from different suppliers, in combination with different container closure systems (CCS), using solutions of different viscosity and surface tension. The different CSTD / CCS combinations were tested for (a) containment (integrity) using a highly sensitive helium leak test, (b) the force required for mounting the vial adaptor, (c) contribution to visible and subvisible particles as well as (d) the hold-up volume. RESULTS: Results show that the majority of CSTDs may have leaks varying in size, and that some of them generated visible particles due to stopper coring and subvisible particles, both due to silicon oil and particulate contaminations of the Devices. Finally, the holdup volume was up to 1 mL depending on the CSTD type, vial size and solution viscosity. CONCLUSION: These results show that there is a need to evaluate the compatibility of CSTD systems to select the best system for the intended use and that CSTDs may adversely impact product quality and delivered dose.


Subject(s)
Drug Packaging/standards , Drug Storage/standards , Health Personnel , Occupational Exposure/prevention & control , Pharmaceutical Preparations/administration & dosage , Protective Devices/standards , Drug Packaging/instrumentation , Equipment Design , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...