Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Forensic Sci Int ; 359: 112001, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38714107

ABSTRACT

BACKGROUND: Cardiac implantable electronic devices (CIED) are a heterogeneous group of medical devices with increasingly sophisticated diagnostic capabilities, which could be exploited in forensic investigations. However, current guidelines are lacking clear recommendations on the topic. The first aim of this systematic review is to provide an updated assessment of the role of postmortem CIED interrogation, and to give practical recommendations, which can be used in daily practice. Secondly, the authors aim to determine the rates of postmortem CIED interrogation and autopsy investigations, the type of final rhythm detected close to death (with a focus on the significance of documented arrhythmias), as well as the role of postmortem CIED interrogation in the determination of final cause/time of death, and any potentially fatal device malfunctions. METHODS: A systematic search in MEDLINE and Scopus aiming to identify reports concerning postmortem human CIED interrogation was performed, including a systematic screening of reference lists. Case reports, letters to the editors, commentaries, review articles or guidelines were excluded, along with studies related to cardiac devices other than CIED. All data were pooled and analyzed using fixed-effects meta-analysis models, and the I2 statistic was used to assess heterogeneity. RESULTS: A total of 25 articles were included in the systematic review, enrolling 3194 decedent CIED carriers. Ten studies (40%) had a 100% autopsy rate, whereas in further 6 studies autopsy findings were variably reported; CIED interrogation was available from 22 studies (88%), and it was never performed prior to autopsy. The overall rate of successful postmortem CIED interrogation was 89%, with high heterogeneity among studies, mainly due to device deactivation/battery discharge. Twenty-four percent of CIED carriers experienced sudden cardiac death (SCD), whereas non-sudden cardiac and non-cardiac death (NSCD, NCD) were reported in 37% and 30% of decedents, respectively. Ventricular tachyarrhythmias were recorded in 34% of overall successfully interrogated CIED, and in 62% of decedents who experienced a SCD; of all ventricular tachyarrhythmias recorded, 40% was found in NSCD or NCD. A clear interpretation of the etiological role of recorded arrhythmias in the causation of death required integration with autopsy findings. Overall, potentially fatal device malfunctions were detected in 12% of cases. CONCLUSIONS: Postmortem CIED interrogation is a valuable tool for the determination of the cause of death, and may complement autopsy. Forensic pathologists need to know the potential utility, pitfalls, and limitations of this diagnostic examination to make this tool as much reliable as possible.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Pacemaker, Artificial/adverse effects , Arrhythmias, Cardiac , Equipment Failure
2.
Pharmaceuticals (Basel) ; 17(2)2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38399464

ABSTRACT

In 2023, hexahydrocannabinol (HHC) attracted the attention of international agencies due to its rapid spread in the illegal market. Although it was discovered in 1940, less is known about the pharmacology of its two naturally occurring epimers, 9(R)-HHC and 9(S)-HHC. Thus, we aimed to investigate the disposition of hexahydrocannabinol epimers and their metabolites in whole blood, urine and oral fluid following a single controlled administration of a 50:50 mixture of 9(R)-HHC and 9(S)-HHC smoked with tobacco. To this end, six non-user volunteers smoked 25 mg of the HHC mixture in 500 mg of tobacco. Blood and oral fluid were sampled at different time points up to 3 h after the intake, while urine was collected between 0 and 2 h and between 2 and 6 h. The samples were analyzed with a validated HPLC-MS/MS method to quantify 9(R)-HHC, 9(S)-HHC and eight metabolites. 9(R)-HHC showed the highest Cmax and AUC0-3h in all the investigated matrices, with an average concentration 3-fold higher than that of 9(S)-HHC. In oral fluid, no metabolites were detected, while they were observed as glucuronides in urine and blood, but with different profiles. Indeed, 11nor-9(R)-HHC was the most abundant metabolite in blood, while 8(R)OH-9(R) HHC was the most prevalent in urine. Interestingly, 11nor 9(S) COOH HHC was detected only in blood, whereas 8(S)OH-9(S) HHC was detected only in urine.

3.
J Pharm Biomed Anal ; 240: 115918, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38181553

ABSTRACT

A sensitive LC-MS/MS method for the simultaneous quantification of the (9 R)- and (9 S)- hexahydrocannabinols (HHCs), and their metabolites, in human urine, oral fluid (OF) and blood samples were developed, validated and used to the biological samples of volunteers. The analytes were extracted from 100 µL human samples. An isocratic elution mode with methanol was used for chromatographic separation of (9 R)- and (9 S)-HHC on an immobilized amylose tris(3-chloro-5-methylphenylcarbamate)-based chiral column Lux i-Amylose-3. The flow-rate of the mobile phase was 0.5 mL/min. An isocratic elution mode of methanol and water (80/20, v/v) was used for chromatographic separation of metabolites of (9 R)- and (9 S)-HHC on a Lux AMP chiral column (with a proprietary chiral selector) at a flow rate of 0.5 mL/min. MS/MS analysis was performed in positive ionization mode for HHC epimers, while in negative ionization mode was used for metabolites of HHCs. The calibration curves for HHCs and their metabolites in human samples ranged from 0.25- 240 ng mL-1 and 1 - 100 ng mL-1, respectively, with determination coefficients (r2) of ≥ 0.99. All analytes were stable at room temperature, 4 °C, in the autosampler (+10 °C) and -20 °C for 24 h, after three freeze/thaw cycles, and when stored at -20 °C up to one week after quality control (QC) sample preparation (concentration differences less than 20% with respect to time zero response), in blood, urine and OF.


Subject(s)
Liquid Chromatography-Mass Spectrometry , Tandem Mass Spectrometry , Humans , Tandem Mass Spectrometry/methods , Chromatography, Liquid/methods , Methanol , Quality Control , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...