ABSTRACT
BACKGROUND: To estimate the depth of field (DOF) achievable with multi-and monofocal intraocular lenses (IOLs) and compare with actual measurements of DOF in cases implanted with a trifocal IOL and biconvex monofocal IOL METHODS: I) Computer simulations were produced to describe the relationship between DOF, pupil size, preoperative ametropia, and retinal blur tolerance limit for a model eye implanted with either multi- or monofocal IOLs. II) Monocular DOF and pupil size were measured under distance viewing conditions between 3 and 6 months postoperative following uneventful cataract surgery. Cases were implanted with either i) trifocal aspheric IOL (n = 36), or ii) biconvex aspheric monofocal IOL (n = 26). DOF was also measured at 0.33 m in cases implanted with i). RESULTS: Simulations revealed significant associations between DOF, pupil size, and retinal blur tolerance limit. The mean (±SD) DOF & pupil sizes were at distance for i) above 2.59D (0.68) & 3.54 mm (0.377), and for ii) above 1.67D (0.51) & 2.90 mm (0.351), and for i) above 3.16D (0.46) at near. The difference between groups were significant for DOF and pupil size at distance (p < 0.001). DOF was significantly greater at near compared with distance in i) above (p < 0.001). For a pupil size of 3 mm, the simulations produce similar DOF values when the tolerance limit of retinal blur is 10 µ. CONCLUSIONS: The DOF was significantly better after implanting the trifocal IOL compared with the monofocal IOL, and DOF is increased under near viewing conditions. The clinical results are similar to calculated DOF values when the tolerance limit of retinal blur is 10 µ.