Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
EuroIntervention ; 19(4): e352-e362, 2023 Jul 17.
Article in English | MEDLINE | ID: mdl-37334801

ABSTRACT

BACKGROUND: TAVI is a widely accepted treatment for patients with severe aortic stenosis (AS). Despite the adoption of diverse therapies, opportunities remain to develop technologies tailored to provide optimal acute and potential long-term benefits, particularly around haemodynamics, flow and durability. AIMS: We aimed to evaluate the safety and feasibility of the DurAVR transcatheter heart valve (THV), a first-in-class biomimetic valve, in the treatment of patients with symptomatic severe AS. METHODS: This was a first-in-human (FIH), prospective, non-randomised, single-arm, single-centre study. Patients with severe, symptomatic AS of any surgical risk and who were eligible for the DurAVR THV prosthesis were recruited; they were assessed at baseline, 30 days, 6 months, and 1 year post-procedure for implant success, haemodynamic performance, and safety. RESULTS: Thirteen patients (73.9±6.4 years old, 77% female) were enrolled. The DurAVR THV was successfully implanted in 100% of cases with no device-related complications. One access site complication, one permanent pacemaker implantation, and one case of moderate aortic regurgitation occurred. Otherwise, no deaths, stroke, bleeding, reinterventions, or myocardial infarction were reported during any of the follow-up visits. Despite a mean annulus size of 22.95±1.09 mm, favourable haemodynamic results were observed at 30 days (effective orifice area [EOA] 2.00±0.17 cm2, and mean pressure gradient [MPG] 9.02±2.68 mmHg) and were sustained at 1 year (EOA 1.96±0.11 cm2, MPG 8.82±1.38 mmHg), resulting in zero patients with any degree of prosthesis-patient mismatch. Additionally, new valve performance measures derived from cardiovascular magnetic resonance displayed restoration of laminar flow, consistent with a predisease state, in conjunction with a mean coaptation length of 8.3±1.7 mm. CONCLUSIONS: Preliminary results from the FIH study with DurAVR THV demonstrate a good safety profile with promising haemodynamic performance sustained at 1 year and restoration of near-normal flow dynamics. Further clinical investigation is warranted to evaluate how DurAVR THV may play a role in addressing the challenge of lifetime management in AS patients.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Prospective Studies , Feasibility Studies , Biomimetics , Treatment Outcome , Prosthesis Design
2.
JACC Heart Fail ; 11(8 Pt 2): 1121-1130, 2023 08.
Article in English | MEDLINE | ID: mdl-37115132

ABSTRACT

BACKGROUND: Most approaches to the creation of an interatrial shunt require placement of a permanent implant to maintain patency. OBJECTIVES: The goal of this study was to investigate the safety and efficacy of a no-implant interatrial shunt for patients with heart failure with preserved ejection fraction (HFpEF) and heart failure with mildly reduced ejection fraction (HFmrEF). METHODS: This was a multicenter, uncontrolled study of patients with HFpEF/HFmrEF and NYHA functional class ≥II, ejection fraction >40%, and pulmonary capillary wedge pressure (PCWP) during supine exercise ≥25 mm Hg with PCWP-to-right atrial gradient ≥5 mm Hg. Follow-up was through 6 months with imaging to assess shunt durability. RESULTS: A total of 28 patients were enrolled: mean age was 68 ± 9 years, and 68% were female. Baseline resting and peak exercise PCWP were 19 ± 7 mm Hg and 40 ± 11 mm Hg, respectively. All procedures displayed technical success with confirmation of left-to-right flow (shunt diameter 7.1 ± 0.9 mm). At 1 month, peak exercise PCWP decreased 5.4 ± 9.6 mm Hg (P = 0.011) with no change in right atrial pressure. There were no serious device or procedure-related adverse events through 6 months. Mean 6-minute walk distance increased 101 ± 71 meters (P < 0.001); Kansas City Cardiomyopathy Questionnaire Overall Summary Score increased 26 ± 19 points (P < 0.001); N-terminal pro-B-type natriuretic peptide decreased 372 ± 857 pg/mL (P = 0.018); and shunt patency was confirmed with unchanged diameter. CONCLUSIONS: In these feasibility studies of a no-implant interatrial shunt, HFpEF/HFmrEF shunts exhibited stability with favorable safety and early efficacy signals. The results show promise toward this new approach for treating patients with HFpEF/HFmrEF and an appropriate hemodynamic profile. (Evaluation of the Safety and Feasibility of a Percutaneously Created Interatrial Shunt to Alleviate Heart Failure Symptoms in Patients With Chronic Heart Failure and Preserved or Mid-Range Left Ventricular Ejection Fraction [ALLEVIATE-HF-1]; NCT04583527; Evaluation of the Safety and Effectiveness of a Percutaneously Created Interatrial Shunt to Alleviate Heart Failure Symptoms in Patients With Chronic Heart Failure and Preserved or Mid-Range Left Ventricular Ejection Fraction [ALLEVIATE-HF-2]; NCT04838353).


Subject(s)
Heart Failure , Ventricular Dysfunction, Left , Humans , Female , Middle Aged , Aged , Male , Stroke Volume , Ventricular Function, Left , Feasibility Studies , Cardiac Catheterization , Ventricular Dysfunction, Left/etiology
3.
Int J Cardiol ; 377: 26-32, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36640966

ABSTRACT

BACKGROUND: Cardiac tamponade caused by temporary right ventricular (RV) pacemaker perforation is a rare but serious complication in transcatheter aortic valve replacement (TAVR). AIMS: To study the incidence of temporary pacemaker related cardiac tamponade in TAVR, and the relation to the type of pacemaker lead used in periprocedural temporary transvenous pacing. METHODS: A single center registry of transfemoral TAVRs in 2014-2020. Main inclusion criterion was peri-operative use of a temporary RV pacing lead. Main exclusion criteria were a preoperatively implanted permanent pacemaker or the exclusive use of left ventricular guidewire pacing. Incident cardiac tamponade was classified as pacemaker lead related, or other. Patients were grouped according to type of temporary RV pacing wire. RESULTS: 810 patients were included (age 80.5 ± 7.3 [mean ± standard deviation], female 319, 39.4%). Of these, 566 (69.9%) received a standard RV temporary pacing wire (RV-TPW), and 244 (30.1%) received temporary RV pacing through a permanent, passive pacemaker lead (RV-TPPL). In total, 18 (2.2%) events of cardiac tamponade occurred, 12 (67%) were pacemaker lead related. All pacemaker lead-related cardiac tamponades occurred in the group who received a standard RV-TPW and none in the group who received RV-TPPL (n = 12 [2.1%] vs. n = 0 [0%], p = 0.022). No difference in cardiac tamponade due to other causes was seen between the groups (p = 0.82). CONCLUSIONS: The use of soft-tip RV-TPPL was associated with a lower risk of pacemaker related cardiac tamponade in TAVR. When perioperative pacing is indicated, temporary RV-TPPL may contribute to a significant reduction of cardiac tamponade in TAVR.


Subject(s)
Aortic Valve Stenosis , Cardiac Tamponade , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Cardiac Tamponade/diagnosis , Cardiac Tamponade/epidemiology , Cardiac Tamponade/etiology , Treatment Outcome , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial , Aortic Valve Stenosis/surgery , Risk Factors , Aortic Valve/surgery
4.
J Invasive Cardiol ; 34(11): E776-E783, 2022 11.
Article in English | MEDLINE | ID: mdl-36227011

ABSTRACT

OBJECTIVES: We aimed to develop and validate an effective prediction model for 1-year mortality risk in elective transfemoral transcatheter aortic valve replacement (TAVR), ie, the TAVR-Risk (TARI) model. BACKGROUND: TAVR is the primary treatment for patients with symptomatic severe aortic valve stenosis; however, risk assessment tools for longer-term outcomes after TAVR remain scarce. METHODS: This retrospective cohort study used logistic regression to test univariate and multivariate associations. The German Aortic Valve Registry (GARY) was the derivation (n = 20,704) and the Swedish SWEDEHEART TAVR Registry (SWENTRY) was the validation cohort (n = 3982). The main outcome was the area under the curve (AUC) in the prediction of 1-year mortality. The final model included 12 parameters that were associated with 1-year mortality in a multivariate analysis. RESULTS: The TARI model (AUC, 0.66; 95% confidence interval [CI] 0.65-0.67) performed better as compared with the Society of Thoracic Surgeons (STS) score (AUC, 0.63; 95% CI, 0.62-0.64; P<.001) and logistic EuroSCORE I (AUC, 0.60; 95% CI, 0.59-0.61; P<.001) in the GARY derivation cohort, and discriminated the risk for 1-year mortality better than logistic EuroSCORE I in the SWENTRY validation cohort (AUC, 0.62; 95% CI, 0.60-0.64 vs AUC, 0.59; 95% CI, 0.57-0.61; P=.04). CONCLUSIONS: This novel TARI score provides a relatively easy-to-use risk model and offers a superior prediction for 1-year mortality in European TAVR patients.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Retrospective Studies , Aortic Valve Stenosis/surgery , Risk Factors , Risk Assessment , Treatment Outcome
5.
HPB (Oxford) ; 24(11): 1854-1860, 2022 11.
Article in English | MEDLINE | ID: mdl-35872123

ABSTRACT

BACKGROUND: Comorbidities increase the risk for postoperative complications after pancreatoduodenectomy. The importance of different categories of heart disease on postoperative outcomes has not been thoroughly studied. METHODS: Patients aged ≥18 years undergoing pancreatoduodenectomy between 2008 and 2019 at Karolinska University Hospital, Sweden were included. Heart disease was defined as a preoperatively established diagnosis, and subcategorized into ischaemic, valvular, heart failure and atrial fibrillation. Postoperative outcome was analysed by multivariable regression. RESULTS: Out of 971 patients, 225 (23.3%) had heart disease. Heart disease was associated with an increased risk for complications; Clavien-Dindo score ≥ IIIa (Odds Ratio [OR] 1.53, 95% confidence interval [CI] 1.07-2.18; p = 0.019), intensive care unit admissions (OR 3.20, 95% CI 1.81-5.66; p < 0.001) and longer hospitalizations (median 14 vs. 11 days; p < 0.001). Although heart disease was not associated with 90-day mortality, it conferred a shorter median overall survival (22 vs. 32 months; p < 0.001). Atrial fibrillation and heart failure were each associated with increased risk for postoperative complications, whereas ischaemic and valvular heart disease were not. CONCLUSION: Atrial fibrillation and heart failure were independently associated with increased risk for postoperative complications. Despite no association with early postoperative mortality, heart disease negatively affected long-term survival.


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Adolescent , Adult , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Pancreaticoduodenectomy/adverse effects , Risk Factors , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/therapy
6.
Int J Cardiol ; 359: 7-13, 2022 07 15.
Article in English | MEDLINE | ID: mdl-35427700

ABSTRACT

BACKGROUND: Arterial access-site related complications constitute a large proportion of adverse events related to cardiac interventions requiring large-bore devices and have significant implications on morbidity, mortality and hospital cost. AIMS: To evaluate the safety and effectiveness of a novel percutaneous plug-based vascular closure device (VCD) in 1000 consecutive patients undergoing transfemoral transcatheter aortic valve implantation (TAVI). METHODS: A single-center observational study evaluating a plug-based VCD (MANTA, Teleflex/Essential Medical Inc., Malvern, Pennsylvania, USA) in patients undergoing TAVI at the Karolinska University Hospital, Stockholm, Sweden. The primary outcome was VCD-related major vascular complication according to the criteria of the Valve Academic Research Consortium (VARC)-2. RESULTS: From May 2017 to September 2020 a total of 1000 consecutive patients underwent transfemoral TAVI with arterial access-site management using the MANTA VCD. VARC-2 major vascular complications occurred in 42 (4.2%) patients: 17 (1.7%) patients intraoperatively received a covered stent, 17 (1.7%) patients underwent surgical repair during hospital stay, 3 (0.3%) patients underwent vascular surgery after discharge, 3 (0.3%) patients had major bleeding and 2 (0.2%) patients had symptoms of claudication with conservative treatment. No significant differences in major complications were seen between individual interventionists irrespective of experience with the device. A larger sheath outer diameter to femoral artery inner diameter ratio was the only factor associated with a significant increase of VCD-related major vascular complications. CONCLUSION: This largest ever real-world evaluation of MANTA for large-bore arteriotomy closure in transfemoral TAVI patients indicates effective and safe arterial access-site management with low complication rates and short learning curve. CLINICAL TRIAL REGISTRATION: http://www. CLINICALTRIALS: gov. Unique identifier: NCT04392492.


Subject(s)
Aortic Valve Stenosis , Catheterization, Peripheral , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Catheterization, Peripheral/adverse effects , Femoral Artery/surgery , Hemostatic Techniques , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Vascular Closure Devices/adverse effects
7.
Struct Heart ; 6(4): 100078, 2022 Aug.
Article in English | MEDLINE | ID: mdl-37288335

ABSTRACT

Background: Heart failure with preserved ejection fraction represents a major unmet clinical need with limited treatment options. Recent device therapies under investigation have focused on decompression of the left atrium through an implantable interatrial shunt. Although these devices have shown favorable safety and efficacy signals, an implant is required to maintain shunt patency, which may increase the patient risk profile and complicate subsequent interventions requiring transseptal access. Methods: The Alleviant System is a no-implant approach to creating an interatrial shunt using radiofrequency energy to securely capture, excise, and extract a precise disk of tissue from the interatrial septum. Acute preclinical studies in healthy swine (n = 5) demonstrated the feasibility of the Alleviant System to repeatably create a 7 mm interatrial orifice with minimal collateral thermal effect and minimal platelet and fibrin deposition observed histologically. Results: Chronic animal studies (n = 9) were carried out to 30- and 60-day time points and exhibited sustained shunt patency with histology demonstrating completely healed margins, endothelialization, and no trauma to adjacent atrial tissue. Preliminary clinical safety and feasibility were validated in a first-in-human study in patients with heart failure with preserved ejection fraction (n = 15). All patients demonstrated shunt patency by transesophageal echocardiographic imaging at 1, 3, and 6 months, as well as cardiac computed tomography imaging at 6-month follow-up timepoints. Conclusions: Combined, these data support the safety and feasibility of a novel no-implant approach to creating an interatrial shunt using the Alleviant System. Continued follow-up and subsequent clinical studies are currently ongoing.

8.
JACC Case Rep ; 3(17): 1828-1835, 2021 Dec 01.
Article in English | MEDLINE | ID: mdl-34917963

ABSTRACT

Transcatheter mitral valve replacement carries a risk of left ventricular outflow tract obstruction associated with mortality. We present a case of left ventricular outflow tract obstruction that resolved spontaneously when chords to the anterior mitral leaflet were found to have ruptured. (Level of Difficulty: Advanced.).

9.
Int J Cardiol ; 294: 32-36, 2019 11 01.
Article in English | MEDLINE | ID: mdl-31399298

ABSTRACT

BACKGROUND: The impact of a change in mitral regurgitation (MR) following TAVR is unknown. We studied the impact of baseline MR and early post-procedural change in MR on survival following TAVR. METHODS: The SWEDEHEART registry included all TAVRs performed in Sweden. Patients were dichotomized into no/mild and moderate/severe MR groups. Vital status, echocardiographic data at baseline and within 7 days after TAVR were analyzed. RESULTS: 1712 patients were included. 1404 (82%) had no/mild MR and 308 (18%) had moderate/severe MR. Baseline moderate/severe MR conferred a higher mortality rate at 5-year follow-up (adjusted HR 1.29, CI 1.01-1.65, p = 0.04). Using persistent ≤mild MR as the reference, when moderate/severe MR persisted or if MR worsened from ≤mild at baseline to moderate/severe after TAVR, higher 5-year mortality rates were seen (adjusted HR 1.66, CI 1.17-2.34, p = 0.04; adjusted HR 1.97, CI 1.29-3.00, p = 0.002, respectively). If baseline moderate/severe MR improved to ≤mild after TAVR no excess mortality was seen (HR 1.09, CI 0.75-1.58, p = 0.67). Paravalvular aortic regurgitation (PVL) was inversely associated with MR improvement after TAVR (OR 0.4, 95%: CI 0.17-0.94; p = 0.034). Atrial fibrillation (OR 2.1, 95% CI: 1.27-3.39, p = 0.004), self-expanding valve (OR 3.8, 95% CI: 2.08-7.14, p < 0.0001), and PVL (4.3, 95% CI 2.32-7.78. p < 0.0001) were associated with MR worsening. CONCLUSIONS: Moderate/severe baseline MR in patients undergoing TAVR is associated with a mortality increase during 5 years of follow-up. This risk is offset if MR improves to ≤mild, whereas worsening of MR after TAVR is associated with a 2-fold mortality increase.


Subject(s)
Aortic Valve Stenosis/surgery , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Comorbidity , Echocardiography , Female , Heart Valve Prosthesis , Humans , Male , Prognosis , Registries , Severity of Illness Index , Survival Rate , Sweden
10.
Obes Res Clin Pract ; 12(1): 51-60, 2018.
Article in English | MEDLINE | ID: mdl-28668555

ABSTRACT

INTRODUCTION: Increased mortality has been observed in those with cardiovascular diseases who are of normal body mass index (BMI) compared to the overweight and the obese. A similar association has been demonstrated in patients undergoing transcatheter aortic valve (TAVI) implantation. However, it still remains unclear whether low or normal BMI itself is unfavourable or whether this is merely a reflection of cardiac cachexia due to severe aortic stenosis. The hypothesis for the study was that weight change prior to TAVI may be associated with increased mortality following the procedure. SUBJECTS, MATERIALS AND METHODS: Single centre retrospective analysis using the SWEDEHEART registry, national mortality statistics and local hospital database. Body mass index was used as the anthropomorphic measurement and patients grouped by WHO categories and weight change trajectory before and at TAVI. Kaplan-Meier survival was constructed and a Cox proportional hazard model used to evaluate predictors of outcome. RESULTS: Consecutive data on 493 patients with three year follow-up between 2008-2015 were evaluated. Overweight and obese body mass index categories (BMI>25) were associated with improved mortality compared to normal and underweight patients (BMI<25) (log rank p=0.02), hazard ratio of 0.68 (0.50-0.93). Weight loss trajectory was associated with increased mortality compared to stable weight (log rank p=0.01), hazard ratio 1.64 p=0.025. CONCLUSION: The pre-procedural weight trajectory of patients undergoing TAVI is an important predictor of clinical outcome after TAVI. Patients with stable weight trajectories are associated with improved mortality outcome compared to those with decreasing weight.


Subject(s)
Aortic Valve Stenosis/mortality , Obesity, Metabolically Benign/mortality , Transcatheter Aortic Valve Replacement/mortality , Aged , Aged, 80 and over , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Body Mass Index , Body-Weight Trajectory , Female , Humans , Male , Obesity, Metabolically Benign/physiopathology , Preoperative Period , Retrospective Studies , Risk Factors , Survival Rate/trends , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
11.
Radiology ; 280(1): 58-61, 2016 07.
Article in English | MEDLINE | ID: mdl-27322973

ABSTRACT

Collateral pathways in vascular disease are important natural "bypass" conduits that protect against ischemia. Endovascular diagnostic and therapeutic procedures via peripheral access sites are performed frequently. This case report underlines the importance of being aware of collateral circulation in patients with chronic aortoiliac occlusive disease undergoing subclavian transcatheter aortic valve implantation to avoid acute limb ischemia. (©) RSNA, 2016.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Iliac Artery/abnormalities , Iliac Artery/diagnostic imaging , Multidetector Computed Tomography/methods , Transcatheter Aortic Valve Replacement/methods , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Echocardiography , Female , Humans
12.
Am J Cardiol ; 116(10): 1639-42, 2015 Nov 15.
Article in English | MEDLINE | ID: mdl-26410607

ABSTRACT

Events that induce emotional stress and frustration in a large number of subjects under specific circumstances, such as earthquakes, war conditions, and sporting occasions, may increase the incidence of cardiovascular events, such as acute myocardial infarction, arrhythmias, and sudden cardiac death. This report describes a married couple who expressed an apparently passionate interest in football with hazardous consequences after a tense football match during the FIFA 2014 World Championships. A series of emotional stressors initiated by defeat in this football game lead to cardiac arrest in a 58-year-old man caused by a thrombotic occlusion of the left anterior descending artery and ending in the death of the patient. An hour and 15 minutes after the onset of cardiac arrest of the patient, his 64-year-old wife also had chest pain caused by an acute midventricular takotsubo syndrome. She survived the acute stage of the disease, and there was complete resolution of the left ventricular dysfunction.


Subject(s)
Death, Sudden, Cardiac/etiology , Spouses/psychology , Stress, Psychological/complications , Takotsubo Cardiomyopathy/complications , Electrocardiography , Fatal Outcome , Female , Humans , Male , Middle Aged , Syndrome
SELECTION OF CITATIONS
SEARCH DETAIL
...