Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
3.
Ann Thorac Surg ; 110(5): e425-e426, 2020 11.
Article in English | MEDLINE | ID: mdl-32353439

ABSTRACT

Truncus arteriosus with interrupted aortic arch represents a complex lesion with high rates of reintervention. We present a novel technique of a composite flap, made possible by aberrant right subclavian anatomy.


Subject(s)
Aorta, Thoracic/abnormalities , Cardiovascular Abnormalities/surgery , Subclavian Artery/abnormalities , Surgical Flaps , Truncus Arteriosus, Persistent/surgery , Aorta, Thoracic/surgery , Humans , Infant , Male , Subclavian Artery/surgery
4.
JTCVS Tech ; 2: 36-37, 2020 Jun.
Article in English | MEDLINE | ID: mdl-34317742
5.
World J Pediatr Congenit Heart Surg ; 11(4): NP103-NP106, 2020 Jul.
Article in English | MEDLINE | ID: mdl-29161959

ABSTRACT

Small infants with severe left ventricular dysfunction (LVD) carry a poor prognosis with limited therapeutic options. Although mechanical support and heart transplantation are definitive therapies, improvement of left ventricular function with reversible pulmonary artery banding (rPAB) has been described. We report two cases of LVD treated with rPAB. One was successfully temporized, and one progressed to requiring transplantation, indicating that appropriate patient selection is critical to this technique's success.


Subject(s)
Pulmonary Artery/surgery , Vascular Surgical Procedures/methods , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left/physiology , Ventricular Function, Right/physiology , Angiography , Extracorporeal Membrane Oxygenation , Humans , Infant , Male , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/surgery
7.
Am Surg ; 83(8): 911-917, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28822401

ABSTRACT

Esophageal perforation is a complex clinical entity that has multiple etiologies and variability in presentation, making it challenging to diagnose and treat. The mortality of esophageal perforation has improved because therapies have evolved. Whereas primary repair is the standard of care, multiple treatments may be employed successfully. We retrospectively reviewed all cases of suspected or confirmed esophageal perforation that were admitted to the thoracic surgery service at our institution between January 2011 and June 2016. We reviewed the charts of 61 patients. Twenty-three underwent primary repair, 13 underwent stent placement, 12 underwent drainage, 12 underwent medical management, and one underwent exclusion and diversion. All patients were included in the final analysis except the singular patient who underwent diversion. Overall mortality was 4.9 per cent. None of the studied variables were found to be associated with mortality (P > 0.05). Factors associated with choice of treatment were age (P < 0.0005), Charlson Index (P = 0.032), etiology (P < 0.0005), and location (P = 0.005). The application of different management options is based on a thorough understanding time course, patient anatomy, severity of presentation, and underlying disease process.


Subject(s)
Esophageal Perforation/therapy , Adult , Aged , Female , Humans , Male , Middle Aged , Retrospective Studies
8.
Eur Radiol ; 27(5): 1944-1953, 2017 May.
Article in English | MEDLINE | ID: mdl-27553939

ABSTRACT

PURPOSE: To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. RESULTS: Besides a higher body-mass-index in group B (24.8±3.8 kg/m2 vs. 28.1±5.4 kg/m2, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). CONCLUSION: TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. KEY POINTS: • Third-generation dual-source CT facilitates low-tube-voltage acquisition. • TAVR planning can be performed with reduced contrast volume and radiation dose. • TAVR-planning CT did not result in changes in creatinine levels at follow-up. • TAVR candidates can be safely evaluated by comprehensive low-tube-voltage CT angiography.


Subject(s)
Aortic Valve Stenosis/surgery , Computed Tomography Angiography/methods , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Cone-Beam Computed Tomography/methods , Contrast Media , Feasibility Studies , Female , Humans , Male , Patient Care Planning , Radiation Dosage , Retrospective Studies , Triiodobenzoic Acids
9.
Eur Radiol ; 27(2): 642-650, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27165140

ABSTRACT

OBJECTIVES: To compare single-energy (SECT) and dual-energy (DECT) abdominal CT examinations in matched patient cohorts regarding differences in radiation dose and image quality performed with second- and third-generation dual-source CT (DSCT). METHODS: We retrospectively analysed 200 patients (100 male, 100 female; mean age 61.2 ± 13.5 years, mean body mass index 27.5 ± 3.8 kg/m2) equally divided into four groups matched by gender and body mass index, who had undergone portal venous phase abdominal CT with second-generation (group A, 120-kV-SECT; group B, 80/140-kV-DECT) and third-generation DSCT (group C, 100-kV-SECT; group D, 90/150-kV-DECT). The radiation dose was normalised for 40-cm scan length. Dose-independent figure-of-merit (FOM) contrast-to-noise ratios (CNRs) were calculated for various organs and vessels. Subjective overall image quality and reader confidence were assessed. RESULTS: The effective normalised radiation dose was significantly lower (P < 0.001) in groups C (6.2 ± 2.0 mSv) and D (5.3 ± 1.9 mSv, P = 0.103) compared to groups A (8.8 ± 2.3 mSv) and B (9.7 ± 2.4 mSv, P = 0.102). Dose-independent FOM-CNR peaked for liver, kidney, and portal vein measurements (all P ≤ 0.0285) in group D. Subjective image quality and reader confidence were consistently rated as excellent in all groups (all ≥1.53 out of 5). CONCLUSIONS: With both DSCT generations, abdominal DECT can be routinely performed without radiation dose penalty compared to SECT, while third-generation DSCT shows improved dose efficiency. KEY POINTS: • Dual-source CT (DSCT) allows for single- and dual-energy image acquisition. • Dual-energy acquisition does not increase the radiation dose in abdominal DSCT. • Third-generation DSCT shows improved dose efficiency compared to second-generation DSCT. • Dose-independent figure-of-merit image contrast was highest with third-generation dual-energy DSCT. • Third-generation DSCT shows improved dose efficiency for SECT and DECT.


Subject(s)
Radiation Dosage , Radiography, Abdominal/methods , Tomography, X-Ray Computed/methods , Abdomen/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Young Adult
11.
Acad Radiol ; 23(12): 1480-1489, 2016 12.
Article in English | MEDLINE | ID: mdl-27614365

ABSTRACT

RATIONALE AND OBJECTIVES: Iterative reconstruction (IR) computed tomography (CT) techniques allow for radiation dose reduction while maintaining image quality. However, CT coronary artery calcium (CAC) scores may be influenced by certain IR algorithms. The aim of our study is to identify suitable correction factors to ensure consistency between IR and filtered back projection (FBP)-based CAC scoring. MATERIAL AND METHODS: A phantom study was performed to derive suitable correction factors for CAC scores and volume (VOL) values with advanced modeled iterative reconstruction (or ADMIRE) strength level 3 (ADM3) and 5 (ADM5) vs FBP. CT data from 40 patients were retrospectively analyzed, and CAC score and VOL values were obtained following reconstruction with FBP, ADM3, and ADM5. Linear regression analysis was performed to obtain correction factors. Results with and without application of the correction factors were compared. Inter-reader agreement for risk class stratification was analyzed. RESULTS: Phantom experiments determined a correction factor of 1.14 for ADM3 and 1.25 for ADM5. FBP-based CAC scores (897 ± 1413) were significantly higher than uncorrected scores with ADM3 (746 ± 1184, P ≤ .001) and ADM5 (640 ± 1036, P ≤ .001). After application of correction factors, no significant differences were found for CAC scores based on FBP (897 ± 1413) and ADM3 (853 ± 1353, P = .07). The inter-reader agreement for risk stratification was excellent (k = 0.91). CONCLUSION: ADM3 can be applied to CAC scoring with use of a correction factor. When applying a correction factor of 1.14, excellent agreement with standard FBP for both CAC score and VOL can be achieved.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Vascular Calcification/diagnostic imaging , Algorithms , Coronary Vessels/diagnostic imaging , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Phantoms, Imaging , Radiation Dosage , Retrospective Studies , Tomography, X-Ray Computed/methods
12.
Acad Radiol ; 22(12): 1562-70, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26432073

ABSTRACT

RATIONALE AND OBJECTIVES: To assess image quality, radiation dose, and diagnostic accuracy of 70-kVp high-pitch computed tomography pulmonary angiography (CTPA) using 40 mL contrast agent and sinogram affirmed iterative reconstruction (SAFIRE) compared to 100-kVp CTPA using 60 mL contrast agent and filtered back projection. MATERIALS AND METHODS: Eighty patients underwent CTPA at either 70 kVp (group A, n = 40; 3.2 pitch, 40 mL contrast medium, and SAFIRE) or 100 kVp (group B, n = 40; 1.2 pitch, 60 mL contrast medium, and filtered back projection). Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was evaluated using a five-grade scale, and diagnostic accuracy was assessed. Radiation doses were compared. RESULTS: Computed tomography values, signal-to-noise ratio, and contrast-to-noise ratio of pulmonary arteries were higher in group A compared to group B (all P < 0.001). Subjective image quality showed no difference between the two groups (P = 0.559) with good interobserver agreement (κ = 0.647). No difference was found regarding diagnostic accuracy between the two groups (P > 0.05). The effective dose for group A was lower by 80% compared to group B (P < 0.001). CONCLUSIONS: 70-kVp high-pitch CTPA with reduced contrast media and SAFIRE provides comparable image quality and substantial radiation dose savings compared to a routine CTPA protocol.


Subject(s)
Angiography/methods , Pulmonary Embolism/diagnosis , Tomography, X-Ray Computed/methods , Adult , Aged , Contrast Media/administration & dosage , Female , Humans , Male , Middle Aged , Prospective Studies , Pulmonary Artery/diagnostic imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Signal Processing, Computer-Assisted , Signal-To-Noise Ratio
13.
PLoS One ; 10(5): e0127876, 2015.
Article in English | MEDLINE | ID: mdl-25955155

ABSTRACT

Treatment of cutaneous wounds with poly-N-acetyl-glucosamine containing nanofibers (pGlcNAc), a novel polysaccharide material derived from a marine diatom, results in increased wound closure, antibacterial activities and innate immune responses. We have shown that Akt1 plays a central role in the regulation of these activities. Here, we show that pGlcNAc treatment of cutaneous wounds results in a smaller scar that has increased tensile strength and elasticity. pGlcNAc treated wounds exhibit decreased collagen content, increased collagen organization and decreased myofibroblast content. A fibrin gel assay was used to assess the regulation of fibroblast alignment in vitro. In this assay, fibrin lattice is formed with two pins that provide focal points upon which the gel can exert force as the cells align from pole to pole. pGlcNAc stimulation of embedded fibroblasts results in cellular alignment as compared to untreated controls, by a process that is Akt1 dependent. We show that Akt1 is required in vivo for the pGlcNAc-induced increased tensile strength and elasticity. Taken together, our findings suggest that pGlcNAc nanofibers stimulate an Akt1 dependent pathway that results in the proper alignment of fibroblasts, decreased scarring, and increased tensile strength during cutaneous wound healing.


Subject(s)
Acetylglucosamine/administration & dosage , Cicatrix/drug therapy , Proto-Oncogene Proteins c-akt/metabolism , Skin/injuries , Tensile Strength/drug effects , Acetylglucosamine/chemistry , Acetylglucosamine/pharmacology , Animals , Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/pharmacology , Gene Expression Regulation/drug effects , Mice , Nanofibers/chemistry , Signal Transduction/drug effects , Skin/drug effects , Wound Healing
14.
Acad Radiol ; 22(7): 890-7, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25872860

ABSTRACT

RATIONALE AND OBJECTIVES: To assess the feasibility of 70-kVp high-pitch non-ECG-gated thoracic aortic computed tomography angiography (CTA) with 40-mL contrast agent compared to 100-kVp standard-pitch CTA with 60-mL contrast agent. MATERIALS AND METHODS: Sixty-seven patients (51 men and 16 women; mean age, 55 ± 14 years) received non-ECG-gated aortic CTA at 70 kVp, high pitch of 3.4, and 40-mL contrast agent (group A, n = 31) or CTA at 100-kVp, pitch of 1.2, and 60-mL contrast agent (group B, n = 36). Iterative reconstruction was used in all patients. For image quality assessment, CTA images were evaluated on a three-point scale and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated and compared. Furthermore, computed tomography (CT) dose index was recorded. RESULTS: Mean CT values and noise levels were higher in group A compared to group B (all P < .001), whereas SNR and CNR were lower than those in group B (all P < .001). Furthermore, the image quality of the aorta at the level of the diaphragm was lower in group A than that in group B (P < .05). However, image quality was graded as diagnostic in all patients, and motion artifacts of the aortic arch were significantly decreased in group A (P <.05). Interreader agreement was good or excellent for image quality assessment (k = 0.625-0.835). The 70-kVp CTA protocol, which allows dose reduction of 85%, was considered diagnostic in all instances by two readers. CONCLUSIONS: Our proposed thoracic aortic CTA protocol provides diagnostic information with substantial reduction of both radiation and contrast agent doses compared to standard-pitch CTA at 100 kVp.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Aortic Diseases/diagnostic imaging , Aortography/methods , Image Interpretation, Computer-Assisted/methods , Radiation Dosage , Tomography, X-Ray Computed/methods , Cardiac-Gated Imaging Techniques , Contrast Media/administration & dosage , Feasibility Studies , Female , Humans , Image Enhancement/methods , Iohexol/administration & dosage , Iohexol/analogs & derivatives , Male , Middle Aged , Radiation Protection/methods , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...