1.
Br J Radiol ; 88(1050): 20140404, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25827204

ABSTRACT

OBJECTIVE: With further increase of CT numbers and their dominant contribution to medical exposure, there is a recent quest for more effective dose control. While reintroduction of iterative reconstruction (IR) has proved its potential in many applications, a novel focus is placed on more noise efficient detectors. Our purpose was to assess the potential of IR in combination with an integrated circuit detector (ICD) for aggressive dose reduction in head CT. METHODS: Non-contrast low-dose head CT [190 mAs; weighted volume CT dose index (CTDIvol), 33.2 mGy] was performed in 50 consecutive patients, using a new noise efficient detector and IR. Images were assessed in terms of quantitative and qualitative image quality and compared with standard dose acquisitions (320 mAs; CTDIvol, 59.7 mGy) using a conventional detector and filtered back projection. RESULTS: By combining ICD and IR in low-dose examinations, the signal to noise was improved by about 13% above the baseline level in the standard-dose control group. Both, contrast-to-noise ratio (2.02 ± 0.6 vs 1.88 ± 0.4; p = 0.18) and objective measurements of image sharpness (695 ± 84 vs 705 ± 151 change in Hounsfield units per pixel; p = 0.79) were fully preserved in the low-dose group. Likewise, there was no significant difference in the grading of several subjective image quality parameters when both noise-reducing strategies were used in low-dose examinations. CONCLUSION: Combination of noise efficient detector with IR allows for meaningful dose reduction in head CT without compromise of standard image quality. ADVANCES IN KNOWLEDGE: Our study demonstrates the feasibility of almost 50% dose reduction in head CT dose (1.1 mSv per scan) through combination of novel dose-reducing strategies.


Subject(s)
Head/diagnostic imaging , Radiation Dosage , Radiation Protection/instrumentation , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Aged , Equipment Design , Female , Humans , Male , Middle Aged , Signal-To-Noise Ratio
2.
Eur J Radiol ; 83(9): 1655-64, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24972451

ABSTRACT

OBJECTIVE: To assess feasibility of whole-body diffusion-weighted MRI (wbDWI) for very early evaluation of response to therapy in different lymphoma subtypes. MATERIALS AND METHODS: 20 patients (10 male, 10 female; mean age 50.7±16.1±17.2 years) underwent wbDWI (calculation of apparent diffusion coefficient [ADC] with b=0, 800s/mm(2)) at baseline and within a median of 7 days after therapy onset. Lymphoma manifestations were evaluated with respect to changes in ADC and size at follow-up with up to six of the largest lesions per patient undergoing quantification. An increase in ADC as well as a decrease in size at follow-up was classified as responder, whereas neither change in ADC nor in size (or progression) was considered non-responder. Results were confirmed at interim measurements (after 3-4 chemotherapy cycles) and 6 months after treatment. RESULTS: 90 lymphoma lesions were analyzed. 18 patients were classified as responders and 2 as non-responder at FU (mean, 1 week). DWI results accurately (100%) correlated with the subsequent interim course of all lesions. mean baseline ADC was 0.79±0.28×10(-3)s/mm(2). For responders mean follow-upADC increased by 64.6±56.5% (p<0.001) whereas lesions size decreased by mean 14.4±13.3% (p<0.001). In the non-responder, both values did not significantly change. In patients classified as responders six months after treatment, meanADC increase at FU was 70.3±57.8% (p<0.001) whereas mean size decrease vs. baseline was 15.8±13.6% as compared to non-responders (22.4±39.9%) and 5.4±0.9%, respectively. CONCLUSION: wbDWI with ADC analysis represents a feasible diagnostic tool for very early response assessment in lymphoma patients enabling also prediction of long-term response.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Lymphoma/diagnosis , Lymphoma/drug therapy , Whole Body Imaging/methods , Adult , Aged , Feasibility Studies , Female , Follow-Up Studies , Humans , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Observer Variation , Prospective Studies , Treatment Outcome , Young Adult
3.
Eur Radiol ; 24(2): 344-52, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24196383

ABSTRACT

OBJECTIVES: To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy. METHODS: Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann-Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated. RESULTS: In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42%) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/Specificity for the following thresholds were calculated: 85 %/73 % and 67 %/92 % for PI-RADS scores of 9 and 10, respectively; 85 %/60 % and 56 %/97 % for Likert scores of 3 and 4, respectively [corrected. CONCLUSIONS: The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score. KEY POINTS: • The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. • To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. • PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. • Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. • The PI-RADS scoring system may contribute to more effective prostate MRI.


Subject(s)
Magnetic Resonance Imaging/methods , Neoplasm Staging/methods , Prostatic Neoplasms/pathology , Aged , Europe , Follow-Up Studies , Humans , Image-Guided Biopsy , Male , Middle Aged , Prospective Studies , ROC Curve , Reproducibility of Results , Societies, Medical , Urology
4.
Eur J Nucl Med Mol Imaging ; 41(5): 887-97, 2014 May.
Article in English | MEDLINE | ID: mdl-24352789

ABSTRACT

PURPOSE: (68)Ga-labelled HBED-CC-PSMA is a highly promising tracer for imaging recurrent prostate cancer (PCa). The intention of this study was to evaluate the feasibility of PET/MRI with this tracer. METHODS: Twenty patients underwent PET/CT 1 h after injection of the (68)Ga-PSMA ligand followed by PET/MRI 3 h after injection. Data from the two investigations were first analysed separately and then compared with respect to tumour detection rate and radiotracer uptake in various tissues. To evaluate the quantification accuracy of the PET/MRI system, differences in SUVs between PET/CT and corresponding PET/MRI were compared with differences in SUVs between PET/CT 1 h and 3 h after injection in another patient cohort. This cohort was investigated using the same PET/CT system. RESULTS: With PET/MRI, different diagnostic sequences, higher contrast of lesions and higher resolution of MRI enabled a subjectively easier evaluation of the images. In addition, four unclear findings on PET/CT could be clarified as characteristic of PCa metastases by PET/MRI. However, in PET images of the PET/MRI, a reduced signal was observed at the level of the kidneys (in 11 patients) and around the urinary bladder (in 15 patients). This led to reduced SUVs in six lesions. SUVmean values provided by the PET/MRI system were different in muscles, blood pool, liver and spleen. CONCLUSION: PCa was detected more easily and more accurately with Ga-PSMA PET/MRI than with PET/CT and with lower radiation exposure. Consequently, this new technique could clarify unclear findings on PET/CT. However, scatter correction was challenging when the specific (68)Ga-PSMA ligand was used. Moreover, direct comparison of SUVs from PET/CT and PET/MR needs to be conducted carefully.


Subject(s)
Edetic Acid/analogs & derivatives , Magnetic Resonance Imaging , Oligopeptides , Positron-Emission Tomography , Prostatic Neoplasms/diagnostic imaging , Radiopharmaceuticals , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Gallium Isotopes , Gallium Radioisotopes , Humans , Male , Middle Aged , Multimodal Imaging , Prostatic Neoplasms/diagnosis
5.
Eur J Radiol ; 82(9): 1431-5, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23587902

ABSTRACT

PURPOSE: Iterative reconstruction has recently been revisited as a promising concept for substantial CT dose reduction. The purpose of this study was to assess the potential benefit of sinogram affirmed iterative reconstruction (SAFIRE) in head CT by comparing objective and subjective image quality at reduced tube current with standard dose filtered back projection (FBP). MATERIALS AND METHODS: Non-contrast reduced dose head CT (255 mAs, CTDIvol 47.8 mGy) was performed in thirty consecutive patients and reconstructed with SAFIRE and FBP. Images were assessed in terms of quantitative and qualitative image quality and compared with FBP of standard dose acquisitions (320 mAs, CTDI vol 59.7 mGy). RESULTS: In reduced dose CT examinations, use of SAFIRE versus FBP resulted in 47% increase in contrast-to-noise ratio (CNR) (2.49 vs. 1.69; p<0.0001). While reduction of tube current was associated with 13% decrease in CNR, quantitative degradation of image quality at lower dose was more than compensated through SAFIRE (2.49 vs. 1.96; p=0.0004). Objective measurements of image sharpness were comparable between FBP and SAFIRE reconstructions (575.9 ± 74.1 vs. 583.4 ± 74.7 change in HU/Pixel; p=0.28). Compared to standard dose FBP, subjective grading of noise as well as overall image quality scores were significantly improved when SAFIRE was used in reduced dose exams (1.3 vs. 1.6, p=0.006; 1.3 vs. 1.7, p=0.026). CONCLUSION: At 20% dose reduction, reconstruction of head CT by SAFIRE provides above standard objective and subjective image quality, suggesting potential for more vigorous dose savings in neuroradiology CT applications.


Subject(s)
Algorithms , Brain Diseases/diagnosis , Craniocerebral Trauma/diagnostic imaging , Radiation Dosage , Radiation Protection/methods , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Adult , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed
6.
Neuroradiology ; 55(4): 423-30, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23223824

ABSTRACT

INTRODUCTION: High-pitch CT angiography (CTA) is a recent innovation that allows significant shortening of scan time with volume coverage of 43 mm per second. The aim of our study was to assess this technique in CTA of the head and neck. METHODS: CTA of supra-aortic arteries was performed in 50 patients using two acquisition protocols: conventional single-source 64-slice (pitch 1.2) and high-pitch dual-source 128-slice CT (pitch 3.2). Subjective and objective image quality of supra-aortic vessel ostia as well as intra- and extra-cranial segments was retrospectively assessed by blinded readers and radiation dose compared between the two protocols. RESULTS: Conventional and high-pitch CTA achieved comparable signal-to-noise ratios in arterial (54.3 ± 16.5 versus 57.3 ± 14.8; p = 0.50) and venous segments (15.8 ± 6.7 versus 18.9 ± 8.9; p = 0.21). High-pitch scanning was, however, associated with sharper delineation of vessel contours and image quality significantly improved at the level of supra-aortic vessel ostia (p < 0.0001) as well as along the brachiocephalic trunk (p < 0.0001), the subclavian arteries (p < 0.0001), proximal common carotid arteries (p = 0.01), and vertebral V1 segments (p < 0.0001). Using the high-pitch mode, the dose-length product was reduced by about 35% (218.2 ± 30 versus 141.8 ± 20 mGy × cm). CONCLUSIONS: Due to elimination of transmitted cardiac motion, high-pitch CTA of the neck improves image quality in the proximity of the aortic arch while significantly lowering radiation dose. The technique thus qualifies as a promising alternative to conventional spiral CTA and may be particularly useful for identification of ostial stenosis.


Subject(s)
Angiography/methods , Aorta, Thoracic/diagnostic imaging , Radiation Dosage , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Aged , Algorithms , Body Burden , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
7.
Can J Neurol Sci ; 39(4): 491-8, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22728857

ABSTRACT

OBJECTIVE: To quantify and compare T2 signal and apparent diffusion coefficient (ADC) in pilocytic and pilomyxoid astrocytoma (PA and PMA) and correlate results with myxoid content. METHODS: Echo-planar diffusion weighted images (DWI) and standard magnetic resonance imaging (MRI) findings were reviewed retrospectively in patients with PA (n=34) and PMA (n=8). Regions of interest (ROIs) were drawn on ADC maps within tumor parts with lowest ADC values. Apparent diffusion coefficient values in tumor were normalized to those in cerebrospinal fluid (ADC/CSF). The ratio of T2 signal intensity in solid tumor parts to CSF (T2/CSF) was registered. Myxoid matrix was histologically quantified retrospectively in 8 PMAs and 17 PAs and correlated with imaging findings. RESULTS: Mean ADC/CSF for PA and PMA was 0.53±0.10 and 0.69±0.10 (p<0.01). Mean T2/CSF for PA and PMA was 0.78±0.19 and 0.93±0.09 (p<0.01). Mean proportion of myxoid tumor matrix in PA was 50% (range, 10-100%) and 93% (range, 90-100%) in PMA (p=0.004). Eight patients (32%; all PA) had less than 50% myxoid content and 17 (68%; 8 PA; 9 PMA) had more. There was positive correlation of ADC/CSF, T2/CSF and ADC (r2=0.61, 0.65 and 0.60 respectively) and significant difference between the groups with more and less than 50% myxoid content (p=0.01 for ADC/CSF and T2/CSF and p=0.02 for ADC). CONCLUSIONS: General imaging features of PA and PMA are non-specific, ADC values and T2 signal intensity are generally higher in the latter, reflecting the proportion of myxoid matrix in these tumors.


Subject(s)
Astrocytoma/classification , Astrocytoma/pathology , Brain Neoplasms/classification , Brain Neoplasms/pathology , Diffusion Tensor Imaging/methods , Magnetic Resonance Imaging/methods , Adolescent , Adult , Aged , Astrocytoma/cerebrospinal fluid , Brain Neoplasms/cerebrospinal fluid , Child , Child, Preschool , Female , Humans , Image Processing, Computer-Assisted , Infant , Infant, Newborn , Male , Middle Aged , Retrospective Studies , Young Adult
10.
Abdom Imaging ; 37(2): 244-51, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21479607

ABSTRACT

OBJECTIVES: To assess the feasibility of a comprehensive MRI protocol using intrabiliary contrast medium (gadolinium-EOB-DTPA) for evaluation of living liver donors. MATERIAL AND METHODS: In this prospective study, 30 donor candidates for living-related liver transplantation (17 men; 13 women, mean age 37 ± 10.9 years) underwent MRI including MR-angiography (MRA) as well as a conventional T2-weighted MR-cholangiography (MRC) and a contrast-enhanced sequence for depiction of the biliary structures. MRC and MRA images were evaluated for quality on a four-point-scale (score of 0 indicated poor and a score of 3, excellent image quality). Anatomic variants of the arterial, venous, portal venous, and biliary structures were identified. RESULTS: Image quality was diagnostic in all examinations except for 4 of 30 MRA data sets. Intrahepatic biliary structures, especially with regard to the intrahepatic bile ducts of 2nd and 3rd order could be identified with significantly increased image quality than in conventional T2-weighted MRC sequences (P = 0.005 and P = 0.035). A high percentage rate of anatomic variants regarding the biliary, arterial, venous, and portal venous anatomy was found. CONCLUSION: This protocol allows the evaluation of liver donors especially with regard to the biliary structures. However, the depiction of the arterial anatomy requires further technical developments.


Subject(s)
Liver Transplantation , Liver/anatomy & histology , Living Donors , Magnetic Resonance Imaging/methods , Adult , Cholangiopancreatography, Magnetic Resonance , Contrast Media , Feasibility Studies , Female , Gadolinium DTPA , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Prospective Studies , Statistics, Nonparametric
11.
AJNR Am J Neuroradiol ; 33(2): 218-24, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22033719

ABSTRACT

BACKGROUND AND PURPOSE: IR has recently demonstrated its capacity to reduce noise and permit dose reduction in abdominal and thoracic CT applications. The purpose of our study was to assess the potential benefit of IR in head CT by comparing objective and subjective image quality with standard FBP at various dose levels. MATERIALS AND METHODS: Ninety consecutive patients were randomly assigned to undergo nonenhanced and contrast-enhanced head CT at a standard dose (320 mAs; CTDI, 60.1) or 15% (275 mAs; CTDI, 51.8) and 30% (225 mAs; CTDI, 42.3) dose reduction. All acquisitions were reconstructed with IR in image space, and FBP and images were assessed in terms of quantitative and qualitative IQ. RESULTS: Compared with FBP, IR resulted in lower image noise (P ≤ .02), higher CNR (P ≤ .03), and improved subjective image quality (P ≤ .002) at all dose levels. While degradation of objective and subjective IQ at 15% dose reduction was fully compensated by IR (CNR, 1.98 ± 0.4 at 320 mAs with FBP versus 2.05 ± 0.4 at 275 mAs with IR; IQ, 1.8 versus 1.7), IQ was considerably poorer at 70% standard dose despite using the iterative approach (CNR, 1.98 ± 0.3 at 320 mAs with FBP versus 1.85 ± 0.4 at 225 mAs with IR, P = .18; IQ, 1.8 versus 2.2, P = .03). Linear regression analysis of CNR against tube current suggests that standard CNR may be obtained until approximately 20.4% dose reduction when IR is used. CONCLUSIONS: Compared with conventional FBP, IR of head CT is associated with significant improvement of objective and subjective IQ and may allow dose reductions in the range of 20% without compromising standard image quality.


Subject(s)
Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Radiation Dosage , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Image Processing, Computer-Assisted/standards , Male , Middle Aged
12.
Acta Radiol ; 52(8): 881-8, 2011 Oct 01.
Article in English | MEDLINE | ID: mdl-21878551

ABSTRACT

Imaging modalities used in the diagnosis of multiple myeloma have evolved and most of them are also suitable for either early or mid-term monitoring of response to novel antimyeloma therapy. This pictorial essay focuses on modern imaging techniques for diagnosis and follow-up of patients with multiple myeloma in order to highlight their individual strengths and limitations. Also, the impact of recently established modern pharmaceutical therapy, like anti-angiogenic medication, on the tumor is addressed.


Subject(s)
Diagnostic Imaging/trends , Multiple Myeloma/diagnosis , Biomarkers, Tumor/analysis , Humans , Magnetic Resonance Imaging/trends , Multiple Myeloma/therapy , Positron-Emission Tomography/trends , Tomography, X-Ray Computed/trends , Ultrasonography/trends , Whole Body Imaging
14.
Eur J Radiol ; 80(2): e120-5, 2011 Nov.
Article in English | MEDLINE | ID: mdl-20833492

ABSTRACT

OBJECTIVES: Calcifications adjacent to the vessel lumen often limit the assessment of stenoses at the carotid bifurcation in 3D multi intensity projection images (3D-MIP) using conventional single energy CT. Aim of the study was to evaluate the diagnostic value of 3D-MIP images after subtraction of bone and calcified plaques (PBS) using dual energy CT for the assessment of carotid bifurcation stenoses. MATERIALS AND METHODS: 36 patients with a total of 46 stenoses at the carotid bifurcation were examined with a dual energy CT system. Grade of the stenoses and plaque morphology were assessed in axial multi planar projections (axMPR) and freely rotatable 3D-MIP images before and after PBS and compared with results from DSA. RESULTS: Grade of the stenosis could be evaluated in all 46 cases in DSA, axMPR and 3D-MIP after PBS. However, in 25 cases grade of the stenosis was not assessable prior to PBS. The average grade of the stenosis increased from DSA (81.4%) to axMPR (83.5%) to 3D-MIP before and after PBS (86.5% and 85.6%). The amount of pseudo-occlusions increased in concordance with the grade of the stenosis (0<9<16). Using 3D-MIP reconstructions, plaque morphology could be evaluated in 32/46 stenoses before PBS and in 44/46 cases after PBS. CONCLUSIONS: PBS facilitated the evaluation of grade of the stenosis in all cases. Nevertheless, after PBS stenoses were overrated in 3D-MIP in comparison to DSA and axMPR. Moreover, plaque morphology, as an independent risk factor for stroke, can be evaluated even in calcified plaques after PBS. Therefore dual energy CTA with plaque subtraction has the potential to identify patients with vulnerable plaques better than conventional CTA.


Subject(s)
Angiography, Digital Subtraction/methods , Calcinosis/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Cerebral Angiography/methods , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results
15.
Eur J Radiol ; 79(3): 389-99, 2011 Sep.
Article in English | MEDLINE | ID: mdl-20478675

ABSTRACT

OBJECTIVE: The objective of this article is to describe MR imaging findings of spinal cord pilocytic astrocytomas at first presentation and following neurosurgery and to discuss briefly some of the most common differential diagnoses. CONCLUSION: MR imaging findings in medullary pilocytic astrocytomas consist generally of focal or diffuse cord-enlarging masses that are irregularly shaped, accompanied by cystic elements and hydromyelia, present different degrees of contrast enhancement, high water diffusivity and a propensity for the thoracic and cervical cord.


Subject(s)
Astrocytoma/diagnosis , Magnetic Resonance Imaging/methods , Spinal Cord Neoplasms/diagnosis , Astrocytoma/surgery , Contrast Media , Diagnosis, Differential , Humans , Spinal Cord Neoplasms/surgery
19.
Rofo ; 182(12): 1105-9, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21104597

ABSTRACT

PURPOSE: To estimate the effective dose of prospectively triggered computed tomography coronary angiography (CTCA) in step-and-shoot (SAS) mode, depending on the tube current and tube voltage modulation. MATERIALS AND METHODS: For dose measurements, an Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a 128-slice single source scanner providing a collimation of 128 × 0.6 mm and a rotation time of 0.38 seconds. CTCA in the SAS mode was acquired with variation of the tube current (160, 240, 320 mAs) and tube voltage (100, 120, 140 kV) at a simulated heart rate of 60 beats per minute and a scan range of 13.5 cm. RESULTS: Depending on gender, tube current and tube voltage, the effective dose of a CTCA in SAS mode varies from 2.8 to 10.8 mSv. Due to breast tissue in the primary scan range, exposure in the case of females showed an increase of up to 60.0 ± .4% compared to males. The dose reduction achieved by a reduction of tube current showed a significant positive, linear correlation to effective dose with a possible decrease in the effective dose of up to 60.4% (r = 0.998; p = 0.044). Disproportionately high, the estimated effective dose can be reduced by using a lower tube voltage with a dose reduction of up to 52.4%. CONCLUSION: Further substantial dose reduction of low-dose CTCA in SAS mode can be achieved by adapting the tube current and tube voltage and should be implemented in the clinical routine, i. e. adapting those protocol parameters to patient body weight.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Coronary Angiography/adverse effects , Image Processing, Computer-Assisted , Phantoms, Imaging , Thermoluminescent Dosimetry , Tomography, X-Ray Computed/adverse effects , Body Burden , Breast/radiation effects , Dose-Response Relationship, Radiation , Female , Humans , Lung/radiation effects , Male , Prospective Studies , Sensitivity and Specificity , Testis/radiation effects , Thyroid Gland/radiation effects