1.
Front Physiol ; 14: 1174188, 2023.
Article in English | MEDLINE | ID: mdl-37123255

ABSTRACT

For blood pumps with a rotating vane-structure, hemolysis values are estimated using a stress-based power-law model. It has been reported that this method does not consider the red blood cell (RBC) membrane's shear resistance, leading to inaccurate estimation of the hemolysis value. The focus of this study was to propose a novel hemolysis model which can more accurately predict the hemolysis value when designing the axial flow blood pump. The movement behavior of a single RBC in the shear flow field was simulated at the mesoscale. The critical value of shear stress for physiological injury of RBCs was determined. According to the critical value, the equivalent treatment of RBC aging was studied. A novel hemolysis model was established considering the RBC's aging and the hemolysis' initial value. The model's validity was verified under the experimental conditions of shear stress loading and the conditions of the shear flow field of the blood pump. The results showed that compared with other hemolysis models for estimating the hemolysis value of blood pumps, the novel hemolysis model proposed in this paper could effectively reduce the estimation error of the hemolysis value and provide a reference for the optimal design of rotary vane blood pumps.

2.
Front Physiol ; 14: 1169905, 2023.
Article in English | MEDLINE | ID: mdl-37250127

ABSTRACT

Blood pump design efforts are focused on enhancing hydraulic effectiveness and minimizing shear stress. Unlike conventional blood pumps, interventional microaxial blood pumps have a unique outflow structure due to minimally invasive technology. The outflow structure, composed of the diffuser and cage bridges, is crucial in minimizing the pump size to provide adequate hemodynamic support. This study proposed four outflow structures of an interventional microaxial blood pump depending on whether the diffuser with or without blades and cage bridges were straight or curved. The outflow flow structure's effect on the blood pump's hydraulic performance and shear stress distribution was evaluated by computational fluid dynamics and hydraulic experiments. The results showed that all four outflow structures could achieve the pressure and flow requirements specified at the design point but with significant differences in shear stress distribution. Among them, the outflow structure with curved bridges would make the blood dispersed more evenly when flowing out of the pump, which could effectively reduce the shear stress at the cage bridges. The outflow structure with blades would aggravate the secondary flow at the leading edge of the impeller, increasing the risk of flow stagnation. The combination of curved bridges and the bladeless diffuser had a relatively better shear stress distribution, with the proportion of fluid exposed to low scalar shear stress (<50 Pa) and high scalar shear stress (>150 Pa) in the blood pump being 97.92% and 0.26%, respectively. It could be concluded that the outflow structure with curved bridges and bladeless diffuser exhibited relatively better shear stress distribution and a lower hemolysis index of 0.00648%, which could support continued research on optimizing the microaxial blood pumps.

3.
J Hazard Mater ; 424(Pt A): 127216, 2022 02 15.
Article in English | MEDLINE | ID: mdl-34592596

ABSTRACT

17ß-estradiol (E2), as one of the pharmaceutical and personal care product, frequently contaminates environmental water as estrogen pollutant and possesses great risk to human survival as well as the sustainable development of the ecosystem. Herein, to achieve an effective adsorbent system for the selective removal of E2 from the environmental water, Fe3O4 nanoparticles are subjected to chemical etching to reduce the overall mass and then employed as carriers to prepare a novel type of lightweight daisy-like magnetic molecularly imprinted polymers (LD-MMIPs) adopting template immobilization strategy. The LD-MMIPs based etched magnetic nanoparticles not only exhibit light mass but also have plentiful imprinted sites in the etched channels, which significantly increases the adsorption capacity for E2. The daisy-like LD-MMIPs own strong magnetic responsiveness, well crystallinity, fast binding kinetics, high adsorption amount, and excellent selectivity. Moreover, combining with HPLC, the LD-MMIPs as adsorbents have been successfully used to specifically recognize and detect trace E2 in environmental water. Thus, the proposed LD-MMIPs with high adsorption capacity hold great potential in monitoring water pollution. Additionally, this work also provides an alternative strategy for improving the adsorption capacity of magnetic molecularly imprinted polymers through a convenient chemical etching technology.


Subject(s)
Molecular Imprinting , Adsorption , Ecosystem , Estradiol , Humans , Magnetic Phenomena , Molecularly Imprinted Polymers
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 39(3): 206-8, 215, 2015 Mar.
Article in Chinese | MEDLINE | ID: mdl-26524788

ABSTRACT

It is difficult to measure the circular arc radius for central angle less than 30 degrees. The existing measuring methods are of low efficiency and big error. Through designing the machine vision system and studying the image detecting method for measurement, It is obtained good results by using the new measurement for tracheal intubation's circular arc radius, Realized a rapid and accurate measurement of the circular arc radius, and expanded the application in the field of machine vision.


Subject(s)
Imaging, Three-Dimensional/instrumentation , Intubation , Trachea , Humans
5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 39(5): 347-8, 2015 Sep.
Article in Chinese | MEDLINE | ID: mdl-26904878

ABSTRACT

At present, the existing problem in nasal feeding perfusion apparatus is laborious and instability. Designing the rolling type perfusion apparatus by using a roller pump, the problem is solved. Compared with the traditional perfusion apparatus, the advantage lies in liquid carrying only need once and simulating human swallowing process. Through testing and verification, the apparatus can be used in nasal feeding perfusion for elderly or patients.


Subject(s)
Enteral Nutrition/instrumentation , Surgical Tape , Aged , Humans , Nose
SELECTION OF CITATIONS