Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ophthalmol Ther ; 9(4): 981-992, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32939747

ABSTRACT

INTRODUCTION: This study evaluates the effects of the multi-pressure dial (MPD) on steady-state pattern electroretinography (ss-pERG) parameters. The study is a randomized, controlled, prospective, pilot trial in a private practice setting with ocular hypertensive (OHT), glaucoma suspect, and open-angle glaucoma (OAG) subjects. METHODS: This study included nine patients (64 ± 9.0 years, nine female) with OHT, glaucoma suspect, or mild OAG. One eye of each subject was randomized to receive negative periocular pressure, while the contralateral eye served as the intrasubject control through the goggle without negative pressure. The Diopsys High Contrast Sensitivity ss-pERG protocol was conducted on both eyes of each subject while wearing the MPD device. Application of negative periocular pressure was set at 50% of baseline intraocular pressure for each study eye. RESULTS: Following 2 h of negative periocular pressure application, the difference in MagnitudeD (MagD) from baseline for eyes randomized to receive negative periocular pressure (+ 0.17 versus - 0.26) was statistically significant (p = 0.023). Over the same period, the change in MagD/Magnitude (MagD/Mag ratio) from baseline for eyes randomized to receive negative periocular pressure was also higher (+ 0.14 versus - 0.16), compared to the control eyes, approached significance (p = 0.059). CONCLUSIONS: Following 2 h of MPD wear, the measured MagD and MagD/Mag ratio improved compared to control, suggesting that negative periocular pressure application to the anterior globe can lead to short-term improvement in one measure of retinal ganglion cell function.

2.
BMC Vet Res ; 8: 139, 2012 Aug 21.
Article in English | MEDLINE | ID: mdl-22909337

ABSTRACT

BACKGROUND: To compare the biomechanical in-vitro characteristics of limited-contact dynamic compression plate (LC-DCP) and locking compression plate (LCP) constructs in an osteotomy gap model of femoral fracture in neonatal calves. Pairs of intact femurs from 10 calves that had died for reasons unrelated to the study were tested. A 7-hole LC-DCP with six 4.5 mm cortical screws was used in one femur and a 7-hole LCP with four 5.0 mm locking and two 4.5 mm cortical screws was used in the corresponding femur. The constructs were tested to failure by cyclic compression at a speed of 2 mm/s within six increasing force levels. RESULTS: The bone-thread interface was stripped in 21 of 80 cortical screws (26.3%) before a pre-set insertion torque of 3 Nm was achieved. Only 3 corresponding intact pairs of constructs could be statistically compared for relative structural stiffness, actuator excursion and width of the osteotomy gap. Relative structural stiffness was significantly greater, actuator excursion and width of the osteotomy gap were significantly smaller in the LCP constructs. While failure occurred by loosening of the screws in the LC-DCP constructs, locking constructs failed by cutting large holes in the soft distal metaphyseal bone. CONCLUSIONS: An insertion torque sufficient to provide adequate stability in femurs of newborn calves could not be achieved reliably with 4.5 mm cortical screws. Another limiting factor for both constructs was the weak cancellous bone of the distal fracture fragment. LCP constructs were significantly more resistant to compression than LC-DCP constructs.


Subject(s)
Animals, Newborn , Bone Plates/veterinary , Bone Screws/veterinary , Fracture Fixation, Internal/veterinary , Animals , Biomechanical Phenomena , Cadaver , Cattle , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...