Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 91(10): 103304, 2020 Oct 01.
Article in English | MEDLINE | ID: mdl-33138550

ABSTRACT

We recently presented the construction of a proportional counter for the absolute measurement of low-energy x-ray emission rates. Its main features were presented in a previous study, along with the testing of its performance as an absolute technique. Full details on its design, construction, and characterization processes are given in this paper. First, the analytical calculations and Monte Carlo simulations that led to the choice of optimal dimensions will be presented, followed by the study of the charge creation and the modeling of the electric field that confirmed that the criteria for a reproducible charge multiplication are met. Afterward, details on the electronics and gas control system will be provided. The dimensional measurements for the accurate determination of the solid angle will be described in detail. Special emphasis will be placed on the production of the detector window, which was made of reduced graphene oxide instead of beryllium. Some tests on the operation of the counter will be presented, namely, the measurement of spectra of several radionuclides that emit x-rays between 3 keV and 9 keV, as well as the fluorescence spectrum of chlorine, at 2.6 keV. A brief explanation of the determination of emission rates will be given, including the approach adopted for the treatment of the escape-peak area. The emission rate measured with the proportional counter was converted into activity concentration using the emission probabilities from the bibliography, in order to compare the results with those obtained by liquid scintillation counting, and both results were found to be in good agreement.

2.
Appl Radiat Isot ; 160: 109113, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32174464

ABSTRACT

A defined-solid-angle proportional counter has been designed for the absolute determination of X-ray emission rates between 2 keV and 10 keV. The main features of the counter are described in this work, and spectra of two radionuclides with low-energy X-ray emissions are presented. The activity concentration of an 55Fe solution was determined by measuring the emission rate of three samples and using tabulated emission probabilities. This activity concentration is compared with the value obtained by liquid scintillation counting, and an excellent agreement has been found.

SELECTION OF CITATIONS
SEARCH DETAIL
...