Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Virol Methods ; 321: 114802, 2023 11.
Article in English | MEDLINE | ID: mdl-37625622

ABSTRACT

Quantification of mpox virus (MPXV) across different human body anatomical sites can provide insights about the most likely transmission routes, so methods able to release absolute and exact quantitative values of MPXV DNA are crucial. Here, we optimized a new QIAcuity digital PCR (dPCR) protocol for the detection and quantification of MPXV DNA in clinical samples and assessed the performance of the assay by comparing the results obtained in 144 biological samples with those resulting from the use of an in-house real-time PCR (qPCR). Overall, the concordance between the two assays was 95%, with samples identified concordantly as MPXV DNA positive and having a mean number of copies per µl of 1708 (95% CI: 107-2830 copies/µl). The remaining samples gave discordant results, with 5 out of 7 detected with the QIAcuity dPCR assay but not with the in-house qPCR. MPXV DNA levels measured by QIAcuity dPCR were strongly correlated with the Ct values detected by in-house qPCR and with those detected by another dPCR assay previously developed in our laboratories. The QIAcuity dPCR assay may be a robust and easy-to-perform method for MPXV DNA quantification in several biological samples.


Subject(s)
Biological Assay , DNA, Viral , Monkeypox virus , Mpox (monkeypox) , Humans , DNA, Viral/genetics , Laboratories , Real-Time Polymerase Chain Reaction , Mpox (monkeypox)/diagnosis , Monkeypox virus/isolation & purification
2.
J Med Virol ; 88(9): 1535-44, 2016 09.
Article in English | MEDLINE | ID: mdl-26864171

ABSTRACT

The Hologic Aptima(®) HIV-1 Quant Dx assay (Aptima HIV) is a real-time transcription-mediated amplification method CE-approved for use in diagnosis and monitoring of HIV-1 infection. The analytical performance of this new assay was compared to the FDA-approved Abbott RealTime HIV-1 (RealTime). The evaluation was performed using 220 clinical plasma samples, the WHO 3rd HIV-1 International Standard, and the QCMD HIV-1 RNA EQA. Concordance on qualitative results, correlation between quantitative results, accuracy, and reproducibility of viral load data were analyzed. The ability to measure HIV-1 subtypes was assessed on the second WHO International Reference Preparation Panel for HIV-1 Subtypes. With clinical samples, inter-assay agreement for qualitative results was high (91.8%) with Cohen's kappa statistic equal to 0.836. For samples with quantitative results in both assays (n = 93), Lin's concordance correlation coefficient was 0.980 (P < 0.0001) and mean differences of measurement, conducted according to Bland-Altman method, was low (0.115 log10 copies/ml). The Aptima HIV quantified the WHO 3rd HIV-1 International Standard diluted from 2000 to 31 cp/ml (5,700-88 IU/ml) at expected values with excellent linearity (R(2) > 0.970) and showed higher sensitivity compared to RealTime being able to detect HIV-1 RNA in 10 out of 10 replicates containing down to 7 cp/ml (20 IU/ml). Reproducibility was very high, even at low HIV-1 RNA values. The Aptima HIV was able to detect and accurately quantify all the main HIV-1 subtypes in both reference panels and clinical samples. Besides excellent performance, Aptima HIV shows full automation, ease of use, and improved workflow compared to RealTime. J. Med. Virol. 88:1535-1544, 2016. © 2016 Wiley Periodicals, Inc.


Subject(s)
HIV Infections/virology , HIV-1/physiology , RNA, Viral/blood , Viral Load , Automation , HIV Infections/diagnosis , HIV-1/genetics , HIV-1/immunology , HIV-1/isolation & purification , Humans , RNA, Viral/genetics , Reagent Kits, Diagnostic , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...