Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Rapid Commun Mass Spectrom ; 27(7): 731-7, 2013 Apr 15.
Article in English | MEDLINE | ID: mdl-23495019

ABSTRACT

RATIONALE: Multiplexed liquid chromatography (LC) coupled with multiple-injection-chromatogram acquisition has emerged as the method of choice for high-speed discovery bioanalysis, because it significantly reduces injection-to-injection cycle time while maintaining the chromatography quality. Historically, systems utilizing this approach had been custom built, and therefore relied on custom software tools to communicate with multiple vendor software for system control, which lacked transferability, flexibility and robustness. METHODS: In this study, we refined a multiplexed bioanalytical system previously reported, by implementing open-deck auto-sampler manifold and multiple-injection-chromatogram acquisition, all on a commercially available system with single software control. RESULTS: As a result of these improvements, the developed LC/tandem mass spectrometry (MS/MS) method on the system was nearly three times faster than the previous method, while demonstrating comparable analytical accuracy, precision and robustness. This system has been evaluated for in vitro ADME screening assays including metabolic stability, CYP inhibition and Caco-2. The biological data generated on the developed system displayed good correlation with those from the previous LC/MS/MS approaches. CONCLUSIONS: The developed platform demonstrated applicability to the in vitro screening assays evaluated and has been successfully implemented to support the high-throughput metabolic stability assay, with a significantly improved bioanalytical throughput, capacity and data turnaround.


Subject(s)
Chromatography, Liquid/methods , Drug Discovery/methods , Software , Tandem Mass Spectrometry/methods , Animals , Caco-2 Cells , Chromatography, Liquid/instrumentation , Cytochrome P-450 CYP3A/analysis , Cytochrome P-450 CYP3A/metabolism , Humans , Linear Models , Mice , Models, Chemical , Propranolol/analysis , Propranolol/chemistry , Rats , Reproducibility of Results
2.
Bioorg Med Chem Lett ; 21(22): 6693-8, 2011 Nov 15.
Article in English | MEDLINE | ID: mdl-21983444

ABSTRACT

Derived from the HTS hit 1, a series of hydroxyisoquinolines was discovered as potent and selective 11ß-HSD1 inhibitors with good cross species activity. Optimization of substituents at the 1 and 4 positions of the isoquinoline group in addition to the core modifications, with a special focus on enhancing metabolic stability and aqueous solubility, resulted in the identification of several compounds as potent advanced leads.


Subject(s)
11-beta-Hydroxysteroid Dehydrogenase Type 1/antagonists & inhibitors , 11-beta-Hydroxysteroid Dehydrogenase Type 1/metabolism , Enzyme Inhibitors/chemistry , Enzyme Inhibitors/pharmacology , Isoquinolines/chemistry , Isoquinolines/pharmacology , Animals , Cell Line , Diabetes Mellitus, Type 2/drug therapy , Enzyme Inhibitors/pharmacokinetics , Humans , Isoquinolines/pharmacokinetics , Mice , Mice, Inbred BALB C , Structure-Activity Relationship
3.
Rapid Commun Mass Spectrom ; 23(11): 1579-91, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19399765

ABSTRACT

Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the bioanalytical method of choice to support plate-based, in vitro early ADME (Absorption, Distribution, Metabolism and Excretion) screens such as metabolic stability (Metstab) assessment. MS/MS method optimization has historically been the bottleneck in this environment, where samples from thousands of discrete compounds are analyzed on a monthly basis, mainly due to the lack of a high-quality commercially available platform to handle the necessary MS/MS method optimization steps for sample analysis by selected reaction monitoring (SRM) on triple quadrupole mass spectrometers. To address this challenge, we recently developed a highly automated bioanalytical platform by successfully integrating QuickQuan 2.0, a unique high-throughput solution featuring MS/MS method optimization by automated infusion, with a customized in-house software tool in support of a Metstab screen. In this platform, a dual-column setup running parallel chromatography was also implemented to reduce the bioanalytical cycle time for LC/MS/MS sample analysis. A set of 45 validation compounds was used to demonstrate the speed, quality and reproducibility of MS/MS method optimization, sample analysis, and data processing using this automated platform. Metstab results for the validation compounds in microsomes from multiple species (human, rat, mouse) showed good consistency within each batch, and also between batches conducted on different days. We have achieved and maintained a monthly throughput of 1300 compound assays representing 500 discrete compounds per instrument per month on this platform, and it has been used to generate metabolic stability data for more than 25 000 compounds to date with an overall success rate of more than 95%.


Subject(s)
Microsomes/metabolism , Tandem Mass Spectrometry/methods , Animals , Automation , Cytochrome P-450 Enzyme System/metabolism , Humans , Mice , Rats , Software
4.
Bioorg Med Chem Lett ; 15(11): 2728-33, 2005 Jun 02.
Article in English | MEDLINE | ID: mdl-15869878

ABSTRACT

In an era of increasing resistance to classical antibacterial agents, the synthetic oxazolidinone series of antibiotics has attracted much interest. Zyvoxtrade mark was the first oxazolidinone to be approved for clinical use against infections caused by multi-drug resistant Gram-positive bacteria. In the course of studies directed toward the discovery of novel antibacterial agents, a new series of synthetic phenyl-isoxazolinone agents that displayed potent activity against Gram-positive bacterial strains was recently discovered at Bristol-Myers Squibb. Extensive investigation of various substitutions on the phenyl ring was then undertaken. We report here, the synthesis and antibacterial activity of a series of biaryl isoxazolinone compounds.


Subject(s)
Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/pharmacology , Isoxazoles/chemistry , Isoxazoles/pharmacology , Animals , Haemophilus influenzae/drug effects , Rats , Structure-Activity Relationship
5.
Antimicrob Agents Chemother ; 46(4): 971-6, 2002 Apr.
Article in English | MEDLINE | ID: mdl-11897577

ABSTRACT

The recent emergence of methicillin-resistant Staphylococcus aureus (MRSA) with decreased susceptibility to vancomycin has intensified the search for alternative therapies for the treatment of infections caused by this organism. One approach has been to identify a beta-lactam with improved affinity for PBP 2a, the target enzyme responsible for methicillin resistance in staphylococci. BMS-247243 is such a candidate, with MICs that inhibit 90% of isolates tested (MIC(90)s) of 4, 2, and 8 microg/ml for methicillin-resistant strains of S. aureus, S. epidermidis, and S. haemolyticus, respectively, as determined on plates with Mueller-Hinton agar and 2% NaCl. The BMS-247243 MICs for MRSA were minimally affected by the susceptibility testing conditions (inoculum size, prolonged incubation, addition of salt to the test medium) or by staphylococcal beta-lactamases. BMS-247243 MIC(90)s for methicillin-susceptible staphylococcal species ranged from < or = 0.25 to 1 microg/ml. The BMS-247243 MIC(90) for beta-lactamase-producing S. aureus strains was fourfold higher than that for beta-lactamase-nonproducing strains. BMS-247243 is hydrolyzed by staphylococcal beta-lactamases at 4.5 to 26.2% of the rates measured for cephaloridine. The affinity of BMS-247243 for PBP 2a was >100-fold better than that of methicillin or cefotaxime. BMS-247243 is bactericidal for MRSA, killing the bacteria twice as fast as vancomycin. These in vitro activities of BMS-247243 correlated with its in vivo efficacy against infections in animals, including the neutropenic murine thigh and rabbit endocarditis models involving MRSA strains. In conclusion, BMS-247243 has in vitro and in vivo activities against methicillin-resistant staphylococci and thus may prove to be useful in the treatment of infections caused by these multidrug-resistant organisms.


Subject(s)
Bacterial Proteins , Carrier Proteins , Methicillin Resistance/physiology , Morpholines/pharmacology , Morpholines/therapeutic use , Muramoylpentapeptide Carboxypeptidase , Pyridines/pharmacology , Pyridines/therapeutic use , Staphylococcal Infections/drug therapy , Staphylococcus aureus/drug effects , Animals , Anti-Bacterial Agents/therapeutic use , Cyclophosphamide/pharmacology , Endocarditis, Bacterial/drug therapy , Endocarditis, Bacterial/microbiology , Hexosyltransferases/genetics , Hexosyltransferases/metabolism , Hydrolysis , Immunosuppression Therapy , Immunosuppressive Agents/pharmacology , Kinetics , Methicillin Resistance/genetics , Mice , Microbial Sensitivity Tests , Morpholines/metabolism , Multienzyme Complexes/genetics , Multienzyme Complexes/metabolism , Muscle, Skeletal/microbiology , Penicillin-Binding Proteins , Peptidyl Transferases/genetics , Peptidyl Transferases/metabolism , Protein Binding , Pyridines/metabolism , Rabbits , Staphylococcal Infections/microbiology , Vancomycin/therapeutic use
6.
Antimicrob Agents Chemother ; 46(4): 1108-11, 2002 Apr.
Article in English | MEDLINE | ID: mdl-11897599

ABSTRACT

BMS-247243, a novel cephalosporin inhibitory for methicillin-resistant staphylococci, primarily has activity against gram-positive bacteria. The activities of BMS-247243, cefotaxime, and ceftriaxone against streptococci and Streptococcus pneumoniae were similar. BMS-247243 inhibits Enterococcus faecalis but not Enterococcus faecium. BMS-247243 also inhibits many inherently vancomycin-resistant species (Leuconstoc, Lactobacillus, Pediococcus) and anaerobic gram-positive bacteria.


Subject(s)
Cephalosporins/pharmacology , Gram-Positive Bacteria/drug effects , Morpholines/pharmacology , Pyridines/pharmacology , Animals , Bacteria/drug effects , Drug Resistance, Microbial , Female , Gram-Positive Bacterial Infections/microbiology , Humans , Immunosuppression Therapy , Mice , Mice, Inbred ICR , Microbial Sensitivity Tests , Penicillin Resistance , Pneumococcal Infections/drug therapy , Pneumococcal Infections/microbiology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...