Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(2)2023 Jan 05.
Article in English | MEDLINE | ID: mdl-36679418

ABSTRACT

Wearable devices have been shown to play an important role in disease prevention and health management, through the multimodal acquisition of peripheral biosignals. However, many of these wearables are exposed, limiting their long-term acceptability by some user groups. To overcome this, a wearable smart sock integrating a PPG sensor and an EDA sensor with textile electrodes was developed. Using the smart sock, EDA and PPG measurements at the foot/ankle were performed in test populations of 19 and 15 subjects, respectively. Both measurements were validated by simultaneously recording the same signals with a standard device at the hand. For the EDA measurements, Pearson correlations of up to 0.95 were obtained for the SCL component, and a mean consensus of 69% for peaks detected in the two locations was obtained. As for the PPG measurements, after fine-tuning the automatic detection of systolic peaks, the index finger and ankle, accuracies of 99.46% and 87.85% were obtained, respectively. Moreover, an HR estimation error of 17.40±14.80 Beats-Per-Minute (BPM) was obtained. Overall, the results support the feasibility of this wearable form factor for unobtrusive EDA and PPG monitoring.


Subject(s)
Galvanic Skin Response , Wearable Electronic Devices , Humans , Photoplethysmography/methods , Feasibility Studies , Foot , Heart Rate
2.
Sensors (Basel) ; 24(1)2023 Dec 29.
Article in English | MEDLINE | ID: mdl-38203076

ABSTRACT

Photoplethysmography (PPG) is used for heart-rate monitoring in a variety of contexts and applications due to its versatility and simplicity. These applications, namely studies involving PPG data acquisition during day-to-day activities, require reliable and continuous measurements, which are often performed at the index finger or wrist. However, some PPG sensors are susceptible to saturation, motion artifacts, and discomfort upon their use. In this paper, an off-the-shelf PPG sensor was benchmarked and modified to improve signal saturation. Moreover, this paper explores the feasibility of using an optimized sensor in the lower limb as an alternative measurement site. Data were collected from 28 subjects with ages ranging from 18 to 59 years. To validate the sensors' performance, signal saturation and quality, wave morphology, performance of automatic systolic peak detection, and heart-rate estimation, were compared. For the upper and lower limb locations, the index finger and the first toe were used as reference locations, respectively. Lowering the amplification stage of the PPG sensor resulted in a significant reduction in signal saturation, from 18% to 0.5%. Systolic peak detection at rest using an automatic algorithm showed a sensitivity and precision of 0.99 each. The posterior wrist and upper arm showed pulse wave morphology correlations of 0.93 and 0.92, respectively. For these locations, peak detection sensitivity and precision were 0.95, 0.94 and 0.89, 0.89, respectively. Overall, the adjusted PPG sensors are a good alternative for obtaining high-quality signals at the fingertips, and for new measurement sites, the posterior pulse and the upper arm allow for high-quality signal extraction.


Subject(s)
Benchmarking , Photoplethysmography , Humans , Upper Extremity , Wrist , Fingers
SELECTION OF CITATIONS