Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Publication year range
1.
Quintessence Int ; 38(8): e506-10, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17823675

ABSTRACT

OBJECTIVE: To assess the effect of metal conditioners on the bond strength between resin cements and cast titanium. METHOD AND MATERIALS: Commercially pure titanium (99.56%) was cast using an arc casting machine. Surfaces were finished with 400-grit silicon carbide paper followed by air abrasion with 50-Microm aluminum oxide. A piece of double-coated tape with a 4-mm circular hole was then positioned on the metal surface to control the area of the bond. The prepared surfaces were then divided into 4 groups (n=10): G1, unprimed Panavia F; G2, Alloy Primer-Panavia F; G3, unprimed Bistite DC; G4, Metaltite-Bistite DC. Forty minutes after insertion of the resin cements, the specimens were detached from the mold and stored in water at 37 degrees C for 24 hours. Shear bond strength was performed in a testing machine (MTS 810) at a crosshead speed of 0.5 mm/min. Data were analyzed using ANOVA and Tukey's test with a .05 significance level. The fractured surfaces were observed through an optical microscope at 103 magnification. RESULTS: The G1 group demonstrated significantly higher shear bond strength (17.95 MPa) than the other groups. G3 (13.79 MPa) and G4 (12.98 MPa) showed similar mean values to each other and were statistically superior to G2 (9.31 MPa). Debonded surfaces generally presented adhesive failure between metal surfaces and resin cements. CONCLUSION: While the Metaltite conditioner did not influence the bond strength of the Bistite DC cement, the Alloy Primer conditioner significantly decreased the mean bond strength of the Panavia F cement.


Subject(s)
Dental Bonding/methods , Resin Cements/chemistry , Titanium/chemistry , Materials Testing/methods , Shear Strength
2.
Rev. odontol. Univ. St. Amaro ; 9(1/2): 47-51, jan./dez. 2004. ilus
Article in Portuguese | BBO - Dentistry | ID: biblio-858539

ABSTRACT

O objetivo deste estudo foi avaliar o efeito da manipulação da silicona de adição Express (3M) com luvas odontológicas na resistência à tração. Foram avaliados três métodos de manipulação: sem luvas - mãos lavadas com sabonete líquido e álcool 70°, sem contato prévio com luvas de látex (grupo controle); luvas de vinil; mãos lavadas com sabonete líquido e álcool 70° após 5 mino em contato com luva de látex. Os corpos-de-prova (7 para cada grupo) na forma de halteres com área de secção retangular de 33mm de comprimento, 6 mm de largura e 3 mm espessura, foram obtidos por meio de uma matriz metálica, preenchida com porções iguais de massa base e catalisadora, manipuladas por 30 segundos. Em seguida, os ensaios mecânicos foram realizados em dois tempos, 5 minutos e 10 minutos após a manipulação, na máquina de testes mecânicos MTS modelo 810 com velocidade de 8,5 mm/min. Não houve diferença estatística entre os tempos para cada método de manipulação individualmente. No tempo de 5 min., os métodos de manipulação apresentaram igualdade estatística. A manipulação com luvas de vinil ou mãos lavadas com sabonete líquido e álcool 70° após contato com luvas de látex não inibiu a polimerização da silicona de adição testada.


Subject(s)
Dental Impression Materials , Gloves, Surgical , Latex , Hand Disinfection , Materials Science
3.
Rev. odontol. UNESP ; 35(3): 171-175, jul.-set. 2006. tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-512578

ABSTRACT

O titânio apresenta características favoráveis que o torna uma excelente alternativa ao uso de ligas áureas, porém seu elevado ponto de fusão e a baixa densidade exigem máquinas especiais de fundição e revestimento resistente para suportar o processo. Esse estudo avaliou a resistência à compressão de três revestimentos fosfatados, sendo um deles específico para titânio Rematitan Plus (RP) e dois alternativos, Rema Exakt (RE) e Castorit Super C (CA), variando-se a temperatura final do ciclo (600, 515 e 430 °C). Para o ensaio de resistência à compressão, os corpos-de-prova cilíndricos (n = 10) com 20 mm de diâmetro e 40 mm de altura foram obtidos em uma matriz metálica bipartida. Após 12 horas, foram submetidos à queima em forno (EDG) conforme instruções do fabricante. Ao atingir a temperatura final programada, foi realizado o teste, em máquina de ensaios mecânicos MTS 810, à velocidade de 2 mm.min-1 até a fratura do corpo-de-prova. Após os testes, os valores de resistência em MPa foram analisados por meio do software SPSS 11.0. Aplicou – se análise de variância e teste de Tukey para comparação dos grupos (P = 0,05). Em cada temperatura, o RE apresentou maior resistência que o RP, que, por sua vez, foi superior ao CA. Analisou-se, também, a influência das temperaturas para cada material. Em geral, os materiais na temperatura final de 600 °C foram mais resistentes do que em 515 e 430 °C, que mostraram comportamento variável. Concluiu-se que o revestimento alternativo RE apresentou resistência à compressão superior à do específico para titânio e que a variação na temperatura final influenciou diferentemente cada material.


The titanium has favorable characteristics that become an excellent alternative to the use of golden alloys. However, his high point of fusion and the low density require special machines of castingand resistant dental investments for this process.This study evaluated the strength to the compression of three phosphate-bonded investments, one of them specific for titanium - Rematitan Plus (RP), and two alternative Rema Exakt (RE) and Castorit Super C (CA), in different end temperatures of the cycle (600, 515 and 430 °C). For the strength to the compression, cylindrical specimens with 20 mm of diameter and 40 mm of height were obtained in a bipartite metallic matrix (n = 10), after 12 hours were submitted to the burns in oven (EDG), in according to the instructions of the manufacturer. Upon reaching the end programmed temperature, was done the test in machine of mechanical test MTS 810 (MTS System Corporation, Minnesota, EUA), in speed of 2mm.min_1 up to fracture of the specimens. After the tests the values of resistance in MPa were analyzed utilizing the software SPSS 11.0. It applied – itself ANOVA and test of Tukey for comparison of the groups (P = 0.05) and compared the material in each temperature, the RE presented bigger resistance than to of the RP, that by his time was a superior to of the CA. Analyzed itself the influence of the temperatures for each material. The materials in the end temperature of 600 °C were more resistant than in 515 and 430 °C. It was possible to conclude that the dental investments RE showed highest strength than the specific investment and the final temperature influenced differently this property of the materials.


Subject(s)
Dental Prosthesis , Dental Casting Investment , Titanium
4.
PCL, Rev. Íbero Am. Prótese Clín. Lab. ; 6(30): 127-233, mar.-abr. 2004. ilus, CD-ROM
Article in Spanish, Portuguese | BBO - Dentistry | ID: biblio-853069

ABSTRACT

O presente trabalho relata um caso clínico de perimólise, uma patologia dental que tem como característica a erosão das coroas dentais. O objetivo é chamar a atenção dos profissionais da classe odontológica para um diagnóstico correto, obtido através da anamnese e do exame de sinais clínicos de descalcificação dentária, para permitir um planejamento adequado da reabilitação oral que, muitas vezes, envolve uma etapa temporária previamente ao tratamento definitivo


Subject(s)
Humans , Male , Adult , Denture, Partial, Removable , Tooth Erosion/therapy , Centric Relation , Vertical Dimension
5.
Rev. bras. odontol ; 58(3): 158-60, maio-jun. 2001. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-296744

ABSTRACT

Mediante as dificuldades encontradas pelos cirugiöes-dentistas em se obter o registro da relaçäo cêntrica pelos métodos tradicionais, esse trabalho tem por objetivo descrever uma técnica para o registro, com base na literatura existente, utilizando folhas calibradoras, cujas vantagens sobre outras técnicas säo a simplicidade e o tempo clínico reduzido, sem que haja perda de qualidade


Subject(s)
Dental Occlusion, Centric , Dental Materials , Jaw Relation Record/methods
6.
Rev. Salusvita (Impr.) ; 19(2): 29-51, jan.-jul. 2000. ilus, tab, graf
Article in Portuguese, English | LILACS | ID: lil-284534

ABSTRACT

A prótese dentária é um recurso para oestabelecimento da normalidade funcional dos pacientes com ausência de dentes. Contudo, é necessário controlar os psssíveis desajustes das próteses, pricipalmente as alteraçöes dos materiais utilizados durante a confecçäo das mesmas, como, por exemplo, a propriedade dos gessos odontológicos. Diante disso, este trabalho buscou calcular a magnitude da expansäo de alguns tipos de gesso encontrados hoje no mercado e comparar os dados da expansäo normal de presa relatado pelos fabricantes com os dados das especificaçöes n§ 25 da American Dental Association (ADA, 1981). Para esta investigaçäo, foram empregados 3 tipos de gessos odontológicos, sendo do tipo III (Mossoró), IV (Densite), V (Exadur). Utilizou-se, para mediçäo, um anel de borracha flexível e um relógio mdidor de expansäo (Mitutoyo - Absolute, in/mm). Foram obtidos dez corpos de prova de cada material e, após 2 horas da espatulaçäo, cada um foi medido om paquímetro eletronico (STARRET) e obteve-se a expansäo total individualmente. Aplicou-se o teste de Kruskal Wallis


Subject(s)
Calcium Sulfate/classification , Diagnosis
7.
PCL ; 2(5): 22-26, jan.-fev.2000. ilus, CD-ROM
Article in Portuguese | BBO - Dentistry | ID: biblio-853223

ABSTRACT

No relato deste caso clínico, os autores apresentam um paciente portador de fissura lábio-palatal, com grande atresia maxilar onde optou-se pela confecção de uma prótese de recobrimento, por se mostrar uma solução otimizada, eficaz e de baixo custo, restabelecendo com sucesso a estética e a função


Subject(s)
Humans , Female , Adult , Cleft Lip , Cleft Palate , Denture, Partial, Removable , Esthetics, Dental , Mouth Rehabilitation
SELECTION OF CITATIONS
SEARCH DETAIL
...