1.
Int J Cardiovasc Imaging ; 32(5): 729-39, 2016 May.
Article in English | MEDLINE | ID: mdl-26723574

ABSTRACT

Stenting for CoA has become an acceptable treatment modality in the last 20 years. However little is known about arterial changes after this procedure. To assess arterial structure and function including peripheral reactivity and stiffness and intima-media thickness (IMT) pre and post stenting for coarctation of the aorta (CoA). Twenty-one patients [median age: 15 years (8-39)] were studied at baseline, 1 day, 6 months and 1 year after stenting. Twenty-one healthy subjects (1:1 matched) were used as controls. Left ventricular (LV) mass, ejection fraction, flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) of left brachial artery, common carotid (CC) and right subclavian artery (RSCA) IMT and pulse wave velocity (PWV) were assessed by echocardiography and vascular ultrasound. CoA patients had higher LV indexed mass (p < 0.0001), impaired FMD (p < 0.0001) and NMD (p < 0.0001), increased PWV (p < 0.0001), carotid and RSCA IMT (both p < 0.0001). All procedures were successful and resulted in significant gradient reduction (p < 0.001). One year after stenting there was improvement in LV function (p = 0.034) and although there was significant reduction of LV mass (103.29 ± 24.77 vs. 74.39 ± 22.07 g/m(2), p < 0.0001) values did not normalize. There was no significant change in FMD, NMD, PWV and CC or RSCA IMT. In patients with CoA, arterial reactivity is impaired and LV mass, arterial stiffness and thickness are increased. Although stenting is successful to relieve the obstruction resulting in better LV function and mass reduction, arterial structure and function remains abnormal after 1 year of follow-up.


Subject(s)
Aortic Coarctation/therapy , Brachial Artery , Carotid Arteries , Endovascular Procedures/instrumentation , Stents , Subclavian Artery , Adolescent , Adult , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/physiopathology , Aortography/methods , Brachial Artery/diagnostic imaging , Brachial Artery/physiopathology , Brazil , Carotid Arteries/diagnostic imaging , Carotid Arteries/physiopathology , Carotid Intima-Media Thickness , Child , Computed Tomography Angiography , Echocardiography , Humans , Observer Variation , Predictive Value of Tests , Prospective Studies , Pulse Wave Analysis , Recovery of Function , Reproducibility of Results , Stroke Volume , Subclavian Artery/diagnostic imaging , Subclavian Artery/physiopathology , Time Factors , Treatment Outcome , Ultrasonography, Doppler , Vascular Remodeling , Vascular Stiffness , Vasodilation , Ventricular Function, Left , Young Adult
2.
Int J Cardiovasc Imaging ; 32(5): 729-739, 2016.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063481

ABSTRACT

Stenting for CoA has become an acceptable treatment modality in the last 20 years. However little is known about arterial changes after this procedure. To assess arterial structure and function including peripheral reactivity and stiffness and intima-media thickness (IMT) pre and post stenting for coarctation of the aorta (CoA). Twenty-one patients [median age: 15 years (8-39)] were studied at baseline, 1 day, 6 months and 1 year after stenting. Twenty-one healthy subjects (1:1 matched) were used as controls. Left ventricular (LV) mass, ejection fraction, flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) of left brachial artery, common carotid (CC) and right subclavian artery (RSCA) IMT and pulse wave velocity (PWV) were assessed by echocardiography and vascular ultrasound. CoA patients had higher LV indexed mass (p < 0.0001), impaired FMD (p < 0.0001) and NMD (p < 0.0001), increased PWV (p < 0.0001), carotid and RSCA IMT (both p < 0.0001). All procedures were successful and resulted in significant gradient reduction (p < 0.001). One year after stenting there was improvement in LV function (p = 0.034) and although there was significant reduction of LV mass (103.29 ± 24.77 vs...


Subject(s)
Carotid Intima-Media Thickness , Stents , Vasodilation
3.
J Cardiovasc Pharmacol ; 55(1): 1-5, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19770669

ABSTRACT

BACKGROUND: Coadministration of any statin with ezetimibe is as effective as using high doses of the same statin in the reduction of low-density lipoprotein cholesterol (LDL-c). There may be other effects called pleiotropics. OBJECTIVE: To compare the effectiveness of 2 different treatments that obtain equivalent LDL-c reductions (80 mg of simvastatin, once a day and coadministration of 10 mg of simvastatin and 10 mg of ezetimibe, once a day) over endothelial function and inflammation. METHODS: Twenty-three randomized patients with hypercholesterolemia in a 2 x 2 crossover protocol were studied. Endothelial function was analyzed by ultrasound assessment of endothelial dependent flow-mediated vasodilation of the brachial artery, and inflammation was estimated by high-sensitivity C-reactive protein (hs-CRP). RESULTS: LDL-c reduction was similar between the 2 treatments with simvastatin/ezetimibe and with simvastatin (P < 0.001); no difference between treatments was found (P = 0.968). Both treatments improved significantly the endothelial function [3.61% with simvastatin/ezetimibe (P = 0.003) and 5.08% with simvastatin (P < 0.001)]; no difference was found between the 2 treatments (P = 0.291). hs-CRP had a 23% reduction with simvastatin/ezetimibe (P = 0.004) and a 30% reduction with simvastatin alone (P = 0.01), with no significant difference between the 2 treatments (P = 0.380). CONCLUSION: The 2 forms of treatment presented similar pleiotropic effects: improvement in endothelial function and decrease in hs-CRP levels.


Subject(s)
Anticholesteremic Agents/therapeutic use , Azetidines/therapeutic use , Hypercholesterolemia/drug therapy , Simvastatin/therapeutic use , Adolescent , Adult , Aged , Anticholesteremic Agents/administration & dosage , Azetidines/administration & dosage , Brachial Artery/diagnostic imaging , Brachial Artery/metabolism , C-Reactive Protein/metabolism , Cholesterol, LDL/blood , Cholesterol, LDL/drug effects , Cross-Over Studies , Drug Therapy, Combination , Endothelium, Vascular/drug effects , Endothelium, Vascular/metabolism , Ezetimibe , Female , Humans , Male , Middle Aged , Simvastatin/administration & dosage , Ultrasonography , Vasodilation/drug effects , Young Adult
4.
J Cardiovasc Pharmacol ; 55: 1-5, 2010.
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063650

ABSTRACT

Background: Coadministration of any statin with ezetimibe is as effective as using high doses of the same statin in the reduction of low-density lipoprotein cholesterol (LDL-c). There may be other effects called pleiotropics. Objective: To compare the effectiveness of 2 different treatments that obtain equivalent LDL-c reductions (80 mg of simvastatin, once a day and coadministration of 10 mg of simvastatin and 10 mg of ezetimibe, once a day) over endothelial function and inflammation. Methods: Twenty-three randomized patients with hypercholesterolemia in a 2 3 2 crossover protocol were studied. Endothelial function was analyzed by ultrasound assessment of endothelial dependent flow-mediated vasodilation of the brachial artery, and inflammation was estimated by high-sensitivity C-reactive protein (hs-CRP). Results: LDL-c reduction was similar between the 2 treatments with simvastatin/ezetimibe and with simvastatin (P , 0.001); no difference between treatments was found (P = 0.968). Both treatments improved significantly the endothelial function [3.61% with simvastatin/


ezetimibe (P = 0.003) and 5.08% with simvastatin (P , 0.001)]; no difference was found between the 2 treatments (P = 0.291). hs-CRP had a 23% reduction with simvastatin/ezetimibe (P = 0.004) and a 30% reduction with simvastatin alone (P = 0.01), with no significant difference between the 2 treatments (P = 0.380).


Subject(s)
Endothelium , Hypercholesterolemia
5.
Arq. bras. cardiol ; 77(5): 471-486, Nov. 2001. ilus, tab
Article in Portuguese, English | LILACS, Sec. Est. Saúde SP | ID: lil-299308

ABSTRACT

We report new percutaneous techniques for perforating the pulmonary valve in pulmonary atresia with intact ventricular septum, in 3 newborns who had this birth defect. There was mild to moderate hypoplastic right ventricle, a patent infundibulum, and no coronary-cavitary communications. We succeeded in all cases, and no complications related to the procedure occurred. The new coaxial radiofrequency system was easy to handle, which simplified the procedure. Two patients required an additional source of pulmonary flow (Blalock-Taussig shunt) in the first week after catheterization. All patients had a satisfactory short-term clinical evolution and will undergo recatheterization within 1 year to define the next therapeutic strategy. We conclude that this technique may be safely and efficiently performed, especially when the new coaxial radiofrequency system is used, and it may become the initial treatment of choice in select neonates with pulmonary atresia and intact ventricular septum


Subject(s)
Humans , Male , Female , Infant, Newborn , Pulmonary Valve , Catheter Ablation , Pulmonary Atresia , Heart Septum