Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Healthcare (Basel) ; 11(21)2023 Nov 03.
Article in English | MEDLINE | ID: mdl-37958042

ABSTRACT

Motor imagery (MI) has been shown to be effective for the acquisition of motor skills; however, it is still unknown whether similar benefits can be achieved in neurological patients. Previous findings of differences in MI ability between people with Parkinson's disease (PwPD) and healthy controls (HCs) are mixed. This study examined differences in the ability to both create and maintain MI as well as investigating the relationship between the ability to create and maintain MI and motor function, independence and quality of life (QoL). A case-control study was conducted (31 PwPD and 31 HCs), collecting gender, age, dominance, socio-demographic data, duration and impact of the disease. MI intensity (MIQ-RS and KVIQ-34) and temporal accuracy of MI (imagined box and block test [iBBT], imagined timed stand and walk test [iTUG]) were assessed. Functional and clinical assessments included upper limb motor function, balance, gait, independence in activities of daily living and quality of life measures. Statistically significant differences in temporal accuracy were observed and partial and weak relationships were revealed between MI measures and functioning, independence and QoL. PwPD retain the ability to create MI, indicating the suitability of MI in this population. Temporal accuracy might be altered as a reflection of bradykinesia on the mentally simulated actions.

2.
J Pers Med ; 13(10)2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37888121

ABSTRACT

BACKGROUND: Therapeutic exercise (TE) recommendations for non-specific low back pain (LBP) are meant to support therapy choices for people who suffer from this condition. The aim of this study was to reach an agreement on the definition and use of TE in the care of people with LBP. METHODS: A Delphi study was carried out with a formal consensus procedure and sufficient scientific evidence, using an established methodology. Four rounds of anonymous questionnaires were administered to create useful suggestions and instructions in terms of the therapeutic activity for patients with LBP, and a group consensus conference. RESULTS: A consensus was reached on most of the questions after 35 physiotherapists completed the questionnaires. Participants agreed that proper TE requires correct posture, body awareness, breathing, movement control, and instruction. Patients with LBP were advised to participate in supervised sessions twice a week for 30 to 60 min for a period of 3 to 6 months. Participants added that tailored evaluation and exercise prescription, monitoring, and functional integration of exercise, as well as using specific equipment, would benefit patients with LBP. CONCLUSIONS: TE recommendations for patients with LBP should be dosed and customized based on their personal psychological needs, level of fitness, and kinesiophobia.

3.
Disabil Rehabil ; : 1-11, 2023 Mar 08.
Article in English | MEDLINE | ID: mdl-36890615

ABSTRACT

PURPOSE: To determine the test-retest reliability and validity of the Imagined Timed Up and Go Test (iTUG) as a Motor Imagery measure of temporal accuracy in people with Parkinson's Disease (PD). MATERIALS AND METHODS: A descriptive study was conducted following the GRRAS recommendations. Thirty-two people with idiopathic, mild to moderate PD (Hoehn and Yahr I-III), without cognitive impairment (MMSE ≥ 24), were assessed twice (7-15 days apart) with the iTUG. The absolute unadjusted difference in seconds, and the absolute adjusted difference as percentage of estimation error, between real and imagined TUG times, were calculated as outcome measures. Test-retest reliability was assessed using a two-way mixed-effects model of the ICC. Construct validity was tested with the Imagined Box and Blocks Test (iBBT) and convergent validity with clinical characteristics of PD, using the Spearman's rank correlation coefficient. RESULTS: The ICC for the unadjusted and adjusted measures of the iTUG was ICC = 0.61 and ICC = 0.55, respectively. Correlations between iTUG and iBBT were not statistically significant. The iTUG was partially correlated to clinical characteristics of PD. CONCLUSIONS: Test-retest reliability of the iTUG was moderate. Construct validity between iTUG and iBBT was poor, so caution should be taken when using them concurrently to assess imagery's temporal accuracy.


In people with Parkinson's Disease (PD), the absolute unadjusted difference (in seconds) and the absolute adjusted difference (as a percentage of estimation error) of the Imagined Timed Up and Go test (iTUG) were moderately reliable.iTUG and Imagined Box and Blocks Test (iBBT) measures were not statistically correlated. Therefore, temporal accuracy measures of Motor Imagery are highly task-dependant and thus their construct validity is poor.Correlations between the adjusted and unadjusted measures of the iTUG and the majority of clinical variables of PD were not statistically significant. Statistically significant correlations were only found between the unadjusted difference and MDS-UPDRS Part III, Schwab and England, and Berg Balance scales, as well as the adjusted difference and disease duration.

4.
J Neurol Phys Ther ; 47(1): 35-43, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36534018

ABSTRACT

BACKGROUND AND PURPOSE: The Kinesthetic and Visual Imagery Questionnaire (KVIQ) and the Movement Imagery Questionnaire-Revised Second Version (MIQ-RS) are measurement instruments that assess motor imagery vividness. The aim of this study was to examine the validity and reliability of the Spanish KVIQ and MIQ-RS in people with Parkinson disease (PD). METHODS: A longitudinal descriptive study was conducted following the COSMIN standards. Thirty-five people with idiopathic PD were evaluated twice (7-15 days apart) with the Spanish KVIQ and MIQ-RS. Structural validity, internal consistency, test-retest reliability (ICC), standard error of measurement (SEM), smallest detectable change (SDC), and criterion validity of the MIQ-RS and KVIQ long (KVIQ-20), short (KVIQ-10), and extended (KVIQ-34) versions and their subscales (if pertinent) were tested. RESULTS: Factor analysis was satisfactory for the MIQ-RS, KVIQ-20, and KVIQ-10, providing evidence of their 2-dimensional structure. Evidence of the structural validity of the KVIQ-34 was not confirmed and thus was analyzed as an overall score. Revelle's ω > 0.9 showed excellent internal consistency. Test-retest reliability was moderate (ICC = 0.58-0.75) and higher for all visual subscales. SEM and SDC were up to 14.39% and 39.89% of the scores, respectively. Criterion validity between questionnaires and subscales was strong (Spearman's r > 0.7). DISCUSSION AND CONCLUSIONS: The results provide evidence for the validity and reliability of the Spanish MIQ-RS, KVIQ-20, and KVIQ-10 to assess motor imagery vividness in people with PD, whereas the KVIQ-34 should only be interpreted as an overall score. Psychometric, procedural, and practical features of the questionnaires should be considered when applying into clinical practice.Video Abstract available for more insights from the authors (see the Video, Supplemental Digital Content 1, available at: http://links.lww.com/JNPT/A401).


Subject(s)
Parkinson Disease , Humans , Reproducibility of Results , Imagery, Psychotherapy , Movement , Surveys and Questionnaires , Psychometrics
5.
Sensors (Basel) ; 20(9)2020 Apr 27.
Article in English | MEDLINE | ID: mdl-32349394

ABSTRACT

BACKGROUND: People with Parkinson's disease (PD) present deficits of the active range of motion (ROM), prominently in their trunk. However, if these deficits are associated with axial rigidity, the functional mobility or health related quality of life (HRQoL), remains unknown. The aim of this paper is to study the relationship between axial ROM and axial rigidity, the functional mobility and HRQoL in patients with mild to moderate PD. METHODS: An exploratory study was conducted. Non-probabilistic sampling of consecutive cases was used. Active trunk ROM was assessed by a universal goniometer. A Biodex System isokinetic dynamometer was used to measure the rigidity of the trunk. Functional mobility was determined by the Get Up and Go (GUG) test, and HRQoL was assessed with the PDQ-39 and EuroQol-5D questionnaires. RESULTS: Thirty-six mild to moderate patients with PD were evaluated. Significant correlations were observed between trunk extensors rigidity and trunk flexion and extension ROM. Significant correlations were observed between trunk flexion, extension and rotation ROM and GUG. Moreover, significant correlations were observed between trunk ROM for flexion, extension and rotations (both sides) and PDQ-39 total score. However, these correlations were considered poor. CONCLUSIONS: Trunk ROM for flexion and extension movements, measured by a universal goniometer, were correlated with axial extensors rigidity, evaluated by a technological device at 30°/s and 45°/s, and functional mobility. Moreover, trunk ROM for trunk flexion, extension and rotations were correlated with HRQoL in patients with mild to moderate PD.


Subject(s)
Parkinson Disease/physiopathology , Range of Motion, Articular/physiology , Biomechanical Phenomena/physiology , Cross-Sectional Studies , Humans , Quality of Life , Torso/physiology , Torso/physiopathology
6.
Sensors (Basel) ; 20(3)2020 Feb 06.
Article in English | MEDLINE | ID: mdl-32041374

ABSTRACT

Rigidity is one of the cardinal symptoms of Parkinson´s disease (PD). Present in up 89% of cases, it is typically assessed with clinical scales. However, these instruments show limitations due to their subjectivity and poor intra- and inter-rater reliability. To compile all of the objective quantitative methods used to assess rigidity in PD and to study their validity and reliability, a systematic review was conducted using the Web of Science, PubMed, and Scopus databases. Studies from January 1975 to June 2019 were included, all of which were written in English. The Strengthening the Reporting of observational studies in Epidemiology Statement (STROBE) checklist for observational studies was used to assess the methodological rigor of the included studies. Thirty-six studies were included. Rigidity was quantitatively assessed in three ways, using servomotors, inertial sensors, and biomechanical and neurophysiological study of muscles. All methods showed good validity and reliability, good correlation with clinical scales, and were useful for detecting rigidity and studying its evolution. People with PD exhibit higher values in terms of objective muscle stiffness than healthy controls. Rigidity depends on the angular velocity and articular amplitude of the mobilization applied. There are objective, valid, and reliable methods that can be used to quantitatively assess rigidity in people with PD.


Subject(s)
Muscle Rigidity/complications , Parkinson Disease/complications , Electromyography , Humans , Joints/physiopathology , Movement , Muscle Rigidity/physiopathology , Muscles/physiopathology , Observational Studies as Topic , Parkinson Disease/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...