Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters










Publication year range
1.
Cardiovasc Digit Health J ; 5(3): 141-148, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38989041

ABSTRACT

Background: Despite near-global availability of remote monitoring (RM) in patients with cardiac implantable electronic devices (CIED), there is a high geographical variability in the uptake and use of RM. The underlying reasons for this geographic disparity remain largely unknown. Objectives: To study the determinants of worldwide RM utilization and identify locoregional barriers of RM uptake. Methods: An international survey was administered to all CIED clinic personnel using the Heart Rhythm Society global network collecting demographic information, as well as information on the use of RM, the organization of the CIED clinic, and details on local reimbursement and clinic funding. The most complete response from each center was included in the current analysis. Stepwise forward multivariate linear regression was performed to identify determinants of the percentage of patients with a CIED on RM. Results: A total of 302 responses from 47 different countries were included, 61.3% by physicians and 62.3% from hospital-based CIED clinics. The median percentage of CIED patients on RM was 80% (interquartile range, 40-90). Predictors of RM use were gross national income per capita (0.76% per US$1000, 95% CI 0.72-1.00, P < .001), office-based clinics (7.48%, 95% CI 1.53-13.44, P = .014), and presence of clinic funding (per-patient payment model 7.90% [95% CI 0.63-15.17, P = .033); global budget 3.56% (95% CI -6.14 to 13.25, P = .471]). Conclusion: The high variability in RM utilization can partly be explained by economic and structural barriers that may warrant specific efforts by all stakeholders to increase RM utilization.

2.
HeartRhythm Case Rep ; 10(5): 378, 2024 May.
Article in English | MEDLINE | ID: mdl-38799596
4.
J Arrhythm ; 39(3): 250-302, 2023 06.
Article in English | MEDLINE | ID: mdl-37324757

ABSTRACT

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.

7.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37208301

ABSTRACT

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Subject(s)
Monitoring, Physiologic , Telemetry , Humans
8.
Heart Rhythm ; 20(9): e92-e144, 2023 09.
Article in English | MEDLINE | ID: mdl-37211145

ABSTRACT

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Subject(s)
Defibrillators, Implantable , Remote Sensing Technology , Humans
12.
J Cardiovasc Electrophysiol ; 32(2): 551-553, 2021 02.
Article in English | MEDLINE | ID: mdl-33345375

ABSTRACT

We introduced a simple technique to eliminate electromagnetic interference between a left ventricular assist device (LVAD) and an implantable cardioverter defibrillator (ICD). A 43-year-old male with heart failure and a reduced ejection fraction who had an ICD presented with decompensated heart failure and received an LVAD as a bridge to transplant. Remote monitoring showed persistent atrial fibrillation causing an inappropriate ICD shock leading to a decision to disable shock therapies. However, an in-office interrogation was unsuccessful due to electromagnetic interference. Patient was instructed to extend his arm above his head on the ipsilateral side of the ICD, thus increasing the distance between LVAD and ICD, eliminating the interaction to allow reprogramming of the device.


Subject(s)
Defibrillators, Implantable , Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Left , Adult , Electromagnetic Phenomena , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Male
13.
Cardiol Rev ; 25(1): 36-42, 2017.
Article in English | MEDLINE | ID: mdl-27922469

ABSTRACT

Many patients with implantable cardioverter-defibrillators (ICD) want to participate in sports and many need or wish to operate a personal motor vehicle. Healthcare providers need to advise patients regarding restrictions related to these activities in the context of the clinical indication for the ICD. Ethical considerations need to be considered when advising ICD patients of restrictions to reduce risk of injury to themselves and to others when participating in either sports or driving. Shared decision-making is necessary to have ICD patients understand and comply with recommended restrictions. Guidelines have been developed based on available studies; however, studies assessing the need for ICD patients to restrict these activities are observational and often out of date. More recent studies challenge driving and sports restrictions that are recommended by the guidelines. Recommendations to ICD patients must be individualized yet be compliant with the guidelines, and need to adapt to changes in a patients' condition.


Subject(s)
Automobile Driving , Defibrillators, Implantable/ethics , Sports/ethics , Decision Making , Humans
14.
Cardiol Rev ; 24(6): 282-287, 2016.
Article in English | MEDLINE | ID: mdl-27548691

ABSTRACT

The use of implantable cardioverter defibrillators (ICD) has favorably impacted the prevention and treatment of sudden cardiac death (SCD) associated with ventricular arrhythmias. However, there are situations where an ICD cannot be immediately implanted, even though the patient is at high risk for SCD. The wearable cardioverter defibrillator (WCD) is a unique technology that can bridge this gap for patients. The WCD has been demonstrated to terminate ventricular tachycardia/fibrillation if worn and used correctly. With proper training, it is relatively easy to put on, maintain, and use. Most patients are compliant and are able to consistently wear the device. The WCD negates the infection risk or procedural complications associated with insertion and possible extraction of leads, as with an ICD. In terms of primary prevention of ventricular tachycardia/fibrillation in patients with a left ventricular ejection fraction ≤35%, prospective, randomized studies evaluating the survival of patients utilizing the WCD will need to be performed before evidenced-based criteria for its use can be established. On the basis of current data, WCD use for those awaiting heart transplant, for those with ICD indications status post-ICD explant, and for high-risk SCD patients with possible reversible cardiomyopathy appears to be a reasonable approach on the basis of current data.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators , Humans , Patient Compliance , Patient Selection
16.
Heart Rhythm ; 11(11): 2056-63, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25016150

ABSTRACT

BACKGROUND: There is a paucity of data regarding the complications and in-hospital mortality after catheter ablation for ventricular tachycardia (VT) in patients with ischemic heart disease. OBJECTIVE: The purpose of this study was to determine the temporal trends in utilization, in-hospital mortality, and complications of catheter ablation of postinfarction VT in the United States. METHODS: We used the 2002-2011 Nationwide Inpatient Sample (NIS) database to identify all patients ≥18 years of age with a primary diagnosis of VT (International Classification of Diseases, Ninth Edition, Clinical Modification [ICD-9-CM] code 427.1) and who also had a secondary diagnosis of prior history of myocardial infarction (ICD-9-CM 412). Patients with supraventricular arrhythmias were excluded. Patients who underwent catheter ablation were identified using ICD-9-CM procedure code 37.34. Temporal trends in catheter ablation, in-hospital complications, and in-hospital mortality were analyzed. RESULTS: Of 81,539 patients with postinfarct VT, 4653 (5.7%) underwent catheter ablation. Utilization of catheter ablation increased significantly from 2.8% in 2002 to 10.8% in 2011 (Ptrend < .001). The overall rate of any in-hospital complication was 11.2% (523/4653), with vascular complications in 6.9%, cardiac in 4.3%, and neurologic in 0.5%. In-hospital mortality was 1.6% (75/4653). From 2002 to 2011, there was no significant change in the overall complication rates (8.4% to 10.2%, Ptrend = .101; adjusted odds ratio [per year] 1.02, 95% confidence interval 0.98-1.06) or in-hospital mortality (1.3% to 1.8%, Ptrend = .266; adjusted odds ratio [per year] 1.03, 95% confidence interval 0.92-1.15). CONCLUSION: The utilization rate of catheter ablation as therapy for postinfarct VT has steadily increased over the past decade. However, procedural complication rates and in-hospital mortality have not changed significantly during this period.


Subject(s)
Catheter Ablation/statistics & numerical data , Hospital Mortality , Myocardial Infarction/complications , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/surgery , Aged , Female , Humans , Middle Aged , Postoperative Complications/mortality , Registries , Risk Factors , United States , Utilization Review
17.
Heart Rhythm ; 5(8): 1134-41, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18675224

ABSTRACT

BACKGROUND: Atrial fibrillation catheter ablation is frequently guided by identification of fractionated electrograms, which are thought to be critical for maintenance of the arrhythmia. Objective automated means for identifying fractionation independent of physician interpretation have not been standardized or validated. OBJECTIVE: The purpose of this study was to standardize and validate an automated algorithm to rapidly identify fractionated electrograms for high-density atrial fibrillation fractionation mapping. METHODS: Left and right atrial fractionation maps were generated by EnSite NavX 6.0 software, using standardized ablation catheters in eight patients with atrial fibrillation. Two blinded electrophysiologists interpreted all electrograms as either fractionated or not fractionated. A stepwise approach was used to optimize automated settings to accurately identify fractionation. High-density fractionation maps were generated with a 20-pole mapping catheter in eight other patients. Two blinded electrophysiologists interpreted all electrograms as near field or far field. The algorithm was refined to optimize settings to exclude far-field signals and retain near-field signals. The sampling segment length was adjusted to optimize recording time to ensure reproducibility. RESULTS: Using 1,514 points, the automated software achieved sensitivity of 0.75 and specificity of 0.80 for identification of fractionated electrograms. Using 725 points collected via multipole catheters with optimal automated settings, 94% of near-field fractionated electrograms were accurately identified. A 6-second sampling length was needed for reproducible fractionation measurements. CONCLUSION: Standardized settings of EnSite NavX 6.0 software with 6-second data collection per point can rapidly and accurately generate high-density fractionation maps independent of physician electrogram interpretation. This may allow for an automated, standardized approach to atrial fibrillation fractionated ablation.


Subject(s)
Atrial Fibrillation/surgery , Body Surface Potential Mapping/methods , Catheter Ablation/methods , Endocardium/pathology , Algorithms , Atrial Fibrillation/physiopathology , Body Surface Potential Mapping/instrumentation , Female , Humans , Male , Middle Aged , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...