Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Invest Radiol ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38960863

ABSTRACT

OBJECTIVES: The aim of this study was to compare the image quality of 7 T turbo spin echo (TSE) knee images acquired with varying factors of parallel-imaging acceleration reconstructed with deep learning (DL)-based and conventional algorithms. MATERIALS AND METHODS: This was a prospective single-center study. Twenty-three healthy volunteers underwent 7 T knee magnetic resonance imaging. Two-, 3-, and 4-fold accelerated high-resolution fat-signal-suppressing proton density (PD-fs) and T1-weighted coronal 2D TSE acquisitions with an encoded voxel volume of 0.31 × 0.31 × 1.5 mm3 were acquired. Each set of raw data was reconstructed with a DL-based and a conventional Generalized Autocalibrating Partially Parallel Acquisition (GRAPPA) algorithm. Three readers rated image contrast, sharpness, artifacts, noise, and overall quality. Friedman analysis of variance and the Wilcoxon signed rank test were used for comparison of image quality criteria. RESULTS: The mean age of the participants was 32.0 ± 8.1 years (15 male, 8 female). Acquisition times at 4-fold acceleration were 4 minutes 15 seconds (PD-fs, Supplemental Video is available at http://links.lww.com/RLI/A938) and 3 minutes 9 seconds (T1, Supplemental Video available at http://links.lww.com/RLI/A939). At 4-fold acceleration, image contrast, sharpness, noise, and overall quality of images reconstructed with the DL-based algorithm were significantly better rated than the corresponding GRAPPA reconstructions (P < 0.001). Four-fold accelerated DL-reconstructed images scored significantly better than 2- to 3-fold GRAPPA-reconstructed images with regards to image contrast, sharpness, noise, and overall quality (P ≤ 0.031). Image contrast of PD-fs images at 2-fold acceleration (P = 0.087), image noise of T1-weighted images at 2-fold acceleration (P = 0.180), and image artifacts for both sequences at 2- and 3-fold acceleration (P ≥ 0.102) of GRAPPA reconstructions were not rated differently than those of 4-fold accelerated DL-reconstructed images. Furthermore, no significant difference was observed for all image quality measures among 2-fold, 3-fold, and 4-fold accelerated DL reconstructions (P ≥ 0.082). CONCLUSIONS: This study explored the technical potential of DL-based image reconstruction in accelerated 2D TSE acquisitions of the knee at 7 T. DL reconstruction significantly improved a variety of image quality measures of high-resolution TSE images acquired with a 4-fold parallel-imaging acceleration compared with a conventional reconstruction algorithm.

2.
J Imaging Inform Med ; 37(2): 892-898, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38343244

ABSTRACT

Modern photon counting detectors allow the calculation of virtual monoenergetic or material decomposed X-ray images but are not yet used for dental panoramic radiography systems. To assess the diagnostic potential and image quality of photon counting detectors in dental panoramic radiography, ethics approval from the local ethics committee was obtained for this retrospective study. Conventional CT scans of the head and neck region were segmented into bone and soft tissue. The resulting datasets were used to calculate panoramic equivalent thickness bone and soft tissue images by forward projection, using a geometry like that of conventional panoramic radiographic systems. The panoramic equivalent thickness images were utilized to generate synthetic conventional panoramic radiographs and panoramic virtual monoenergetic radiographs at various energies. The conventional, two virtual monoenergetic images at 40 keV and 60 keV, and material-separated bone and soft tissue panoramic equivalent thickness X-ray images simulated from 17 head CTs were evaluated in a reader study involving three experienced radiologists regarding their diagnostic value and image quality. Compared to conventional panoramic radiographs, the material-separated bone panoramic equivalent thickness image exhibits a higher image quality and diagnostic value in assessing the bone structure p < . 001 and details such as teeth or root canals p < . 001 . Panoramic virtual monoenergetic radiographs do not show a significant advantage over conventional panoramic radiographs. The conducted reader study shows the potential of spectral X-ray imaging for dental panoramic imaging to improve the diagnostic value and image quality.

3.
Rofo ; 2023 Nov 23.
Article in English | MEDLINE | ID: mdl-37995734

ABSTRACT

PURPOSE: To assess diagnostic delay in patients with osteoid osteoma and to analyze influencing factors. MATERIALS AND METHODS: All patients treated for osteoid osteoma at our tertiary referral center between December 1997 and February 2021 were retrospectively identified (n = 302). The diagnosis was verified by an expert panel of radiologists and orthopedic surgeons. The exclusion criteria were post-interventional recurrence, missing data on symptom onset, and lack of pretherapeutic CT images. Clinical parameters were retrieved from the local clinical information system. CT and MR images were assessed by a senior specialist in musculoskeletal radiology. RESULTS: After all exclusions, we studied 162 patients (mean age: 24 ±â€Š11 years, 115 men). The average diagnostic delay was 419 ±â€Š485 days (median: 275 days; range: 21-4503 days). Gender, patient age, presence of nocturnal pain, positive aspirin test, extent of bone sclerosis, and location of the tumor within bone and relative to joints did not influence diagnostic delay (p > 0.05). It was, however, positively correlated with nidus size (r = 0.26; p < 0.001) and was shorter with affection of long tubular bones compared to all other sites (p = 0.04). If osteoid osteoma was included in the initial differential diagnoses, the diagnostic delay was also shorter (p = 0.007). CONCLUSION: The diagnostic delay in patients with osteoid osteoma is independent of demographics, clinical parameters, and most imaging parameters. A long average delay of more than one year suggests low awareness of the disease among physicians. Patients with unclear imaging findings should thus be referred to a specialized musculoskeletal center or an expert in the field should be consulted in a timely manner. KEY POINTS: · In this retrospective study of 162 patients treated for osteoid osteoma, the median diagnostic delay was 275 days (range: 21-4503 days).. · Gender, age, presence of nocturnal pain, positive aspirin test, extent of bone sclerosis, and location of the tumor did not influence the diagnostic delay (p > 0.05).. · Diagnostic delay was positively correlated with nidus size (r = 0.26; p < 0.001) and was shorter with affection of long tubular bones compared to all other sites (376 ±â€Š485 vs. 560 ±â€Š462 days; p = 0.04)..

SELECTION OF CITATIONS
SEARCH DETAIL
...