Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Anal Toxicol ; 43(4): 266-276, 2019 May 01.
Article in English | MEDLINE | ID: mdl-30462229

ABSTRACT

Fentanyl, and the numerous drugs derived from it, are contributing to the opioid overdose epidemic currently underway in the USA. To identify human exposure to these growing public health threats, an LC-MS-MS method for 5 µL dried blood spots (DBS) was developed. This method was developed to detect exposure to 3-methylfentanyl, alfentanil, α-methylfentanyl, carfentanil, fentanyl, lofentanil, sufentanil, norcarfentanil, norfentanyl, norlofentanil, norsufentanil, and using a separate LC-MS-MS injection, cyclopropylfentanyl, acrylfentanyl, 2-furanylfentanyl, isobutyrylfentanyl, ocfentanil and methoxyacetylfentanyl. Preparation of materials into groups of compounds was used to accommodate an ever increasing need to incorporate newly identified fentanyls. This protocol was validated within a linear range of 1.00-100 ng/mL, with precision ≤12% CV and accuracy ≥93%, as reported for the pooled blood QC samples, and limits of detection as low as 0.10 ng/mL. The use of DBS to assess fentanyl analog exposures can facilitate rapid sample collection, transport, and preparation for analysis that could enhance surveillance and response efforts in the ongoing opioid overdose epidemic.


Subject(s)
Analgesics, Opioid/blood , Dried Blood Spot Testing/methods , Drug Overdose/blood , Drug Overdose/epidemiology , Fentanyl/analogs & derivatives , Fentanyl/blood , Substance Abuse Detection/methods , Analgesics, Opioid/chemical synthesis , Autopsy , Chromatography, Liquid , Data Accuracy , Fentanyl/chemical synthesis , Furans/blood , Hematocrit , Humans , Humidity/prevention & control , Illicit Drugs/blood , Tandem Mass Spectrometry , United States/epidemiology
2.
Chem Res Toxicol ; 31(9): 898-903, 2018 09 17.
Article in English | MEDLINE | ID: mdl-30133262

ABSTRACT

Microcystins are toxins produced by many cyanobacteria species, which are often released into waterways during blue-green algal blooms in freshwater and marine habitats. The consumption of microcystin-contaminated water is a public health concern as these toxins are recognized tumor promoters and are hepatotoxic to humans and animals. A method to confirm human exposures to microcystins is needed; therefore, our laboratory has developed an immunocapture liquid chromatography tandem mass spectrometry (LC-MS/MS) method targeting the conserved adda portion of microcystins for the quantitation of a prevalent and highly toxic congener of microcystin, microcystin-LR (MC-LR). An acute exposure method was initially evaluated for accuracy and precision by analyzing calibrators and quality control (QC) samples ranging from 0.500 to 75.0 ng/mL in urine. All calibrators and QC samples characterized were within 15% of theoretical concentrations. An analysis of acutely exposed mouse urine samples using this method identified MC-LR levels from 10.7 to 33.9 ng/mL. Since human exposures are anticipated to result from low-dose or chronic exposures, a high-sensitivity method was validated with 20 calibration curves and QC samples ranging from 0.0100 to 7.50 ng/mL. Relative standard deviations (RSDs) and inaccuracies of these samples were within 15%, meeting United States Food and Drug Administration (FDA) guidelines for analytical methods, and the limit of detection was 0.00455 ng/mL. In conclusion, we have developed a method which can be used to address public health concerns by precisely and accurately measuring MC-LR in urine samples.


Subject(s)
Chromatography, Liquid/methods , Microcystins/urine , Animals , Cyanobacteria/metabolism , Female , Humans , Limit of Detection , Male , Marine Toxins , Mice , Quality Control , Reproducibility of Results , Tandem Mass Spectrometry/methods
3.
Toxicon ; 133: 110-115, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28495477

ABSTRACT

Saxitoxin (STX) is a potent marine toxin that causes paralytic shellfish poisoning (PSP) which can result in significant morbidity and mortality in humans. Low lethal doses, rapid onset of PSP symptoms, and brief STX half-life in vivo require sensitive and rapid diagnostic techniques to monitor human exposures. Our laboratory has validated an enzyme-linked immunosorbent assay (ELISA) for quantitative detection of STX from 0.020 to 0.80 ng/mL in human whole blood and from 0.06 to 2.0 ng/mL in dried human blood which is simple, sensitive, rapid, and cost-effective. To our knowledge, this is the first validated method for the quantitation of saxitoxin in whole blood. Microsampling devices were used in sample collection which allows for standardized collection of blood, stable storage, and cost-efficient shipping. Quality control precision and accuracy were evaluated over the course of validation and were within 20% of theoretical concentrations. No detectable background concentrations of STX were found among fifty whole blood and dried blood convenience samples. Additionally, ten spiked individual whole blood and dried blood samples were tested for accuracy and precision and were within 20% of theoretical concentrations. Gonyautoxins 2&3 (GTX2&3) cross-reacted with this ELISA by 21%, but all other structurally related PSP toxins tested cross-reacted less than two percent. While clinical diagnosis or treatment of PSP would be unaffected by GTX2&3 cross-reactivity by ELISA, to accurately quantify individual PSP toxins, these results should be coupled with high performance liquid chromatography mass spectrometry measurements.


Subject(s)
Enzyme-Linked Immunosorbent Assay/methods , Saxitoxin/analysis , Saxitoxin/blood , Blood Specimen Collection/methods , Cross Reactions , Humans , Reproducibility of Results , Saxitoxin/analogs & derivatives , Shellfish Poisoning/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...