Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Nat Rev Cardiol ; 2024 May 07.
Article in English | MEDLINE | ID: mdl-38710772

ABSTRACT

This Perspective article is a form of 'pastiche', inspired by the 1993 review by Lincoff and Topol entitled 'Illusion of reperfusion', and explores how their concept continues to apply to percutaneous revascularization in patients with coronary artery disease and ischaemia. Just as Lincoff and Topol argued that reperfusion of acute myocardial infarction was facing unresolved obstacles that hampered clinical success in 1993, we propose that challenging issues are similarly jeopardizing the potential benefits of stent-based angioplasty today. By analysing the appropriateness and efficacy of percutaneous coronary intervention (PCI), we emphasize the limitations of relying solely on visual angiographic guidance, which frequently leads to inappropriate stenting and overtreatment in up to one-third of patients and the associated increased risk of periprocedural myocardial infarction. The lack of optimal revascularization observed in half of patients undergoing PCI confers risks such as suboptimal physiology after PCI, residual angina and long-term stent-related events, leaving an estimated 76% of patients with an 'illusion of revascularization'. These outcomes highlight the need to refine our diagnostic tools by integrating physiological assessments with targeted intracoronary imaging and emerging strategies, such as co-registration systems and angiography-based computational methods enhanced by artificial intelligence, to achieve optimal revascularization outcomes.

2.
Article in English | MEDLINE | ID: mdl-38775442

ABSTRACT

Coronary physiological assessment has garnered extensive application in managing patients with coronary artery disease, encompassing both acute and chronic scenarios. Beyond the historical purpose as tool to define the hemodynamic significance of a given artery lesion, coronary artery physiology allows for a complete investigation of epicardial and microvascular circulation. The longitudinal assessment of the distribution pattern of coronary disease based on pressure wire technology provides crucial information to define the best management and procedural planning. Moreover, post-percutaneous coronary intervention physiology reassessment showed a strong association with clinical outcomes and, more importantly, it can spot residual pressure gradients potentially amenable to further intervention and optimization. Growing evidence about the non-invasive angiography-based indices helps to overcome the limitations of the use of intracoronary physiology. This review aims to provide an overview of different utilizations of coronary physiology offering a historical perspective with a particular focus on current challenges and future potential applications.

3.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

4.
Curr Cardiol Rep ; 26(5): 359-372, 2024 May.
Article in English | MEDLINE | ID: mdl-38619711

ABSTRACT

PURPOSE OF REVIEW: Acute coronary syndromes (ACS) are a major global health concern. Percutaneous coronary intervention (PCI) with new-generation drug-eluting stents (DES) has been endorsed as safe and effective in the management of culprit and non-culprit lesions of ACS. However, permanent metallic implants may have drawbacks, including the need for prolonged dual antiplatelet therapy (DAPT) and the risk of long-term stent-related complications. An alternative approach using drug-coated balloons (DCBs) is gaining growing interest, having the potential of delivering therapy directly to vulnerable plaques, avoiding the need for permanent metallic implants, and potentially allowing for better long-term medical treatment. Despite limited evidence, DCB is being explored in several patients' subgroups. This review aims to discuss the existing evidence regarding DCB in ACS management. RECENT FINDINGS: DCB appears to be a promising strategy in the management of ACS, showing comparable angiographic and clinical results as compared to new-generation DES in relatively small clinical trials or large prospective registries. The advantage of avoiding permanent implants is particularly appealing in this setting, where DCB has the potential of delivering anti-atherogenic local therapy directly to vulnerable plaques still amenable to atherogenic regression. This review seeks to underline the theoretical background of DCB use and reports the available evidence in its support in the specific setting of ACS. In the context of ACS, the use of DCB is highly attractive, offering a dedicated anti-atherogenic local therapy, capable of addressing a broad range of vulnerable plaques and patients.


Subject(s)
Acute Coronary Syndrome , Angioplasty, Balloon, Coronary , Drug-Eluting Stents , Humans , Acute Coronary Syndrome/therapy , Treatment Outcome , Percutaneous Coronary Intervention/methods , Coated Materials, Biocompatible , Platelet Aggregation Inhibitors/therapeutic use
5.
Article in English | MEDLINE | ID: mdl-38664133

ABSTRACT

Balloon angioplasty achieves luminal enlargement by fracturing the atherosclerotic intima at its point of least resistance, thereby creating a dissection plane and space with dehiscence of the intima from the media. This barotraumatic dissection triggers an inflammatory and proliferative reaction, resulting in a restenosis process at medium-term. In the era of plain old balloon angioplasty, quantitative angiographic studies at follow-up demonstrated that - the greater the acute luminal gain was after balloon angioplasty, the greater the late luminal loss was at follow-up. The interventional cardiologists coined the following motto "the more you gain, the more you lose". However, in the current era of drug coated balloon (DCB), it appears that this vexing conundrum could have been abrogated. A recently published DCB study in small de novo vessel has demonstrated that there was a slightly negative correlation between the volume of dissection assessed by optical coherence tomography and the angiographic late luminal loss (now gain) after Paclitaxel coated balloon treatment. In other words, the barotraumatic dissection does not necessarily herald a restenosis process in the era of DCB. This article revisits the mechanism of balloon angioplasty and explores how DCB with Paclitaxel may change the paradigm of balloon angioplasty as default treatment in CAD percutaneous treatment.

6.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38479968

ABSTRACT

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Registries , Stroke/etiology
7.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38401656

ABSTRACT

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Female , Aortic Valve Stenosis/surgery , Sex Factors , Aged, 80 and over , Aged , Treatment Outcome , Postoperative Complications/epidemiology , Aortic Valve/surgery
9.
Clin Res Cardiol ; 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38170246

ABSTRACT

BACKGROUND: Cardiac allograft vasculopathy (CAV) is still the main drawback of heart transplantation (HTx) and percutaneous coronary intervention (PCI) is a palliative measure because of the high incidence of failure. OBJECTIVE: This study aimed to investigate the safety and efficacy of bioresorbable scaffolds (BRSs) as potential novel therapeutic tool for the treatment of coronary stenoses in CAV. METHODS: This is a multicenter, single-arm, prospective, open-label study (CART, NCT02377648), that included patients affected by advanced CAV treated with PCI and second-generation ABSORB BRS (Abbott Vascular). The primary endpoint was the incidence of 12-month angiographic in-segment scaffold restenosis (ISSR). Secondary endpoints were the incidence of major adverse cardiac events (MACEs) at 12- and 36-month follow-up and the incidence of ISSR at 36 months. A paired intracoronary imaging analysis at baseline and follow-up was also performed. RESULTS: Between 2015 and 2017 35 HTx patients were enrolled and treated for 44 coronary lesions with 51 BRSs. The primary endpoint occurred in 13.5% of the lesions (5/37), with a cumulative ISSR rate up to 3 years of 16.2% (6/37). Angiographic lumen loss was 0.40 ± 0.62 mm at 12 months and 0.53 ± 0.57 mm at 36 months. Overall survival rate was 91.4% and 74.3%, and MACEs incidence 14.2% and 31.4% at 12 and 36 months, respectively. At the paired intracoronary imaging analysis, a significant increase of the vessel external elastic membrane area in the treated segment and some progression of CAV proximally to the BRS were detected. CONCLUSIONS: BRS-based PCI for the treatment of CAV is feasible and safe, with an ISSR incidence similar to what reported in retrospective studies with drug-eluting stents.

10.
Heart ; 110(8): 603-612, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38040448

ABSTRACT

OBJECTIVES: This study aimed to evaluate the prognostic value of coronary microvascular dysfunction (CMD) at long term after transcatheter aortic valve implantation (TAVI) and to explore its relationship with extravalvular cardiac damage (EVCD). Moreover, we sought to test the correlation between angiography-derived index of microcirculatory resistance (IMRangio) and invasive IMR in patients with aortic stenosis (AS). METHODS: This was a retrospective analysis of the Verona Valvular Heart Disease Registry (Italy) including 250 patients (83 (80-86) years, 53% female) with severe AS who underwent TAVI between 2019 and 2021. IMRangio was calculated offline using a computational flow model applied to coronary angiography obtained during the TAVI workup. CMD was defined as IMRangio ≥30 units.The primary endpoint was the composite of cardiovascular death and rehospitalisation for heart failure (HF). Advanced EVCD was defined as pulmonary circulation impairment, severe tricuspid regurgitation or right ventricular dysfunction.The correlation between IMR and IMRangio was prospectively assessed in 31 patients undergoing TAVI. RESULTS: The primary endpoint occurred in 28 (11.2%) patients at a median follow-up of 22 (IQR 12-30) months. Patients with CMD met the primary endpoint more frequently than those without CMD (22.9% vs 2.8%, p<0.0001). Patients with CMD were more frequently characterised by advanced EVCD (33 (31.4%) vs 27 (18.6%), p=0.024). CMD was an independent predictor of adverse outcomes (adjusted HR 6.672 (2.251 to 19.778), p=0.001) and provided incremental prognostic value compared with conventional clinical and imaging variables. IMRangio demonstrated fair correlation with IMR. CONCLUSIONS: CMD is an independent predictor of cardiovascular mortality and HF after TAVI.


Subject(s)
Aortic Valve Stenosis , Myocardial Ischemia , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Microcirculation , Treatment Outcome , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
12.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37982161

ABSTRACT

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Registries , Stroke/etiology , Prosthesis Design
13.
JACC Asia ; 3(5): 689-706, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38095005

ABSTRACT

Coronary physiologic assessment is performed to measure coronary pressure, flow, and resistance or their surrogates to enable the selection of appropriate management strategy and its optimization for patients with coronary artery disease. The value of physiologic assessment is supported by a large body of evidence that has led to major recommendations in clinical practice guidelines. This expert consensus document aims to convey practical and balanced recommendations and future perspectives for coronary physiologic assessment for physicians and patients in the Asia-Pacific region based on updated information in the field that including both wire- and image-based physiologic assessment. This is Part 1 of the whole consensus document, which describes the general concept of coronary physiology, as well as practical information on the clinical application of physiologic indices and novel image-based physiologic assessment.

14.
JACC Cardiovasc Interv ; 16(23): 2884-2896, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37877914

ABSTRACT

BACKGROUND: There are no data comparing sirolimus-coated balloons (SCBs [MagicTouch, Concept Medical]) to paclitaxel-coated balloons (PCBs [SeQuent Please Neo, B. Braun]) for the treatment of de novo small vessel disease (SVD). OBJECTIVES: This study sought to compare quantitative coronary angiographic outcomes at 6 months after treatment of de novo SVD with a PCB or SCB. METHODS: This prospective, multicenter, noninferiority trial randomized 121 patients (129 SVD lesions) to treatment with an SCB or PCB, with balloon sizing determined using optical coherence tomography. The primary endpoint was noninferiority for the 6-month angiographic net lumen gain. RESULTS: Angiographic follow-up was completed in 109 (90.1%) patients in the per-protocol analysis. The mean ± SD angiographic net gains were 0.25 ± 0.40 mm with SCBs vs 0.48 ± 0.37 mm with PCBs, resulting in SCBs failing to meet the 0.30 mm criterion for noninferiority (Pnoninferiority = 0.173), with an absolute difference of -0.23 mm (95% CI: -0.37 to -0.09) secondary to a smaller late loss (0.00 ± 0.32 mm vs 0.32 ± 0.47 mm; P < 0.001) and more frequent late lumen enlargement (53.7% vs 30.0%; OR: 2.60; 95% CI: 1.22-5.67; P = 0.014) with PCBs. Binary restenosis rates were 32.8% and 12.5% following treatment with SCBs and PCBs, respectively (OR: 3.41; 95% CI: 1.36-9.44; P = 0.012). The mean angiography-derived fractional flow ratio at follow-up was 0.86 ± 0.15 following treatment with SCBs and 0.91 ± 0.09 following PCBs (P = 0.026); a fractional flow ratio ≤0.80 occurred in 13 and 5 vessels after treatment with SCBs and PCBs, respectively. CONCLUSIONS: The SCB MagicTouch failed to demonstrate noninferiority for angiographic net lumen gain at 6 months compared to the PCB SeQuent Please Neo.


Subject(s)
Angioplasty, Balloon, Coronary , Paclitaxel , Sirolimus , Vascular Diseases , Humans , Coated Materials, Biocompatible , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Paclitaxel/therapeutic use , Polychlorinated Biphenyls , Prospective Studies , Sirolimus/therapeutic use , Treatment Outcome , Vascular Diseases/therapy
15.
Catheter Cardiovasc Interv ; 102(7): 1401-1405, 2023 12.
Article in English | MEDLINE | ID: mdl-37694603

ABSTRACT

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prosthesis Design
16.
Circ Cardiovasc Interv ; 16(10): e013185, 2023 10.
Article in English | MEDLINE | ID: mdl-37712285

ABSTRACT

BACKGROUND: Angiography-derived computational physiology is an appealing alternative to pressure-wire coronary physiology assessment. However, little is known about its reliability in the setting of severe aortic stenosis. This study sought to provide an integrated assessment of epicardial and microvascular coronary circulation by means of single-view angiography-derived physiology in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). METHODS: Pre-TAVI angiographic projections of 198 stenotic coronary arteries (123 patients) were analyzed by means of Murray's law-based quantitative flow ratio and angiography microvascular resistance. Wire-based reference measurements were available for comparison: fractional flow reserve (FFR) in all cases, instantaneous wave-free ratio in 148, and index of microvascular resistance in 42 arteries. RESULTS: No difference in terms of the number of ischemia-causing stenoses was detected between FFR ≤0.80 and Murray's law-based quantitative flow ratio ≤0.80 (19.7% versus 19.2%; P=0.899), while this was significantly higher when instantaneous wave-free ratio ≤0.89 (44.6%; P=0.001) was used. The accuracy of Murray's law-based quantitative flow ratio ≤0.80 in predicting pre-TAVI FFR ≤0.80 was significantly higher than the accuracy of instantaneous wave-free ratio ≤0.89 (93.4% versus 77.0%; P=0.001), driven by a higher positive predictive value (86.9% versus 50%). Similar findings were observed when considering post-TAVI FFR ≤0.80 as reference. In 82 cases with post-TAVI angiographic projections, Murray's law-based quantitative flow ratio values remained stable, with a low rate of reclassification of stenosis significance (9.9%), similar to FFR and instantaneous wave-free ratio. Angiography microvascular resistance demonstrated a significant correlation (Rho=0.458; P=0.002) with index of microvascular resistance, showing an area under the curve of 0.887 (95% CI, 0.752-0.964) in predicting index of microvascular resistance ≥25. CONCLUSIONS: Angiography-derived physiology provides a valid, reliable, and systematic assessment of the coronary circulation in a complex scenario, such as severe aortic stenosis.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Fractional Flow Reserve, Myocardial/physiology , Coronary Angiography , Reproducibility of Results , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Coronary Vessels/diagnostic imaging , Treatment Outcome , Predictive Value of Tests , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Severity of Illness Index
17.
Eur Heart J Case Rep ; 7(8): ytad309, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37539351

ABSTRACT

Background: Physiology-guided coronary revascularization was shown to improve clinical outcomes in multiple patient subsets, whilst in those presenting with acute coronary syndromes, it seems to be associated with an excess of cardiovascular events. One of the major drawbacks in this setting is the potential deferral of non-flow-limiting but 'vulnerable' coronary plaques. Case summary: A 40-year-old patient presented with a myocardial infarction without ST-segment elevation (NSTEMI). At the invasive coronary angiography (ICA) a sub-occlusive stenosis on his left circumflex artery was detected and treated with percutaneous coronary intervention (PCI). The treatment of a concomitant intermediate eccentric focal stenosis on the right coronary artery (RCA) was deferred after a negative pressure wire-based physiological assessment. The patient was re-admitted 9 months later due to a recurrent NSTEMI, and a severe progression of the deferred RCA lesion was found at the ICA. In retrospect, an angiography-based assessment of physiological severity and plaque vulnerability of the non-culprit RCA stenosis by means of Murray's law-based QFR (µQFR) and radial wall strain (RWS) was performed. At baseline, µQFR value (0.90) corroborated the non-ischaemic findings of wire-based assessment. However, RWS analysis showed a marked hotspot (maximum RWS value 27.7%), indicating the presence of a vulnerable plaque. Discussion: Radial wall strain is a novel biomechanical deformation index derived from coronary angiography. Segments with high RWS are associated with lipid-rich plaques that are prone to progression and plaque rupture. Therefore, the identification of RWS hotspots might potentially improve the risk stratification of non-culprit lesions and empower secondary prevention strategies.

18.
J Clin Med ; 12(14)2023 Jul 22.
Article in English | MEDLINE | ID: mdl-37510950

ABSTRACT

(1) Background: Conduction disturbance requiring a new permanent pacemaker (PPM) after transcatheter aortic valve implantation (TAVI) has traditionally been a common complication. New implantation techniques with self-expanding platforms have reportedly reduced the incidence of PPM. We sought to investigate the predictors of PPM at 30 days after TAVI using Evolut R/PRO/PRO+; (2) Methods: Consecutive patients who underwent TAVI with the Evolut platform between October 2019 and August 2022 at University Hospital Galway, Ireland, were included. Patients who had a prior PPM (n = 10), valve-in-valve procedures (n = 8) or received >1 valve during the index procedure (n = 3) were excluded. Baseline clinical, electrocardiographic (ECG), echocardiographic and multislice computed tomography (MSCT) parameters were analyzed. Pre-TAVI MSCT analysis included membranous septum (MS) length, a semi-quantitative calcification analysis of the aortic valve leaflets, left ventricular outflow tract, and mitral annulus. Furthermore, the implantation depth (ID) was measured from the final aortography. Multivariate binary logistic analysis and receiver operating characteristic (ROC) curve analysis were used to identify independent predictors and the optimal MS and ID cutoff values to predict new PPM requirements, respectively; (3) Results: A total of 129 TAVI patients were included (age = 81.3 ± 5.3 years; 36% female; median EuroSCORE II 3.2 [2.0, 5.4]). Fifteen patients (11.6%) required PPM after 30 days. The patients requiring new PPM at 30 days were more likely to have a lower European System for Cardiac Operative Risk Evaluation II, increased prevalence of right bundle branch block (RBBB) at baseline ECG, have a higher mitral annular calcification severity and have a shorter MS on preprocedural MSCT analysis, and have a ID, as shown on the final aortogram. From the multivariate analysis, pre-TAVI RBBB, MS length, and ID were shown to be predictors of new PPM. An MS length of <2.85 mm (AUC = 0.85, 95%CI: (0.77, 0.93)) and ID of >3.99 mm (area under the curve (AUC) = 0.79, (95% confidence interval (CI): (0.68, 0.90)) were found to be the optimal cut-offs for predicting new PPM requirements; (4) Conclusions: Membranous septum length and implantation depth were found to be independent predictors of new PPM post-TAVI with the Evolut platform. Patient-specific implantation depth could be used to mitigate the requirement for new PPM.

SELECTION OF CITATIONS
SEARCH DETAIL
...