ABSTRACT

PURPOSE: In the present study, the precision of two patient-specific instrumentation (PSI) systems for total knee arthroplasty (TKA) was evaluated by comparing bony resection thicknesses of the pre-operative PSI planning and intra-operative measurements by a vernier calliper. It was hypothesized that the data provided by pre-operative planning were accurate within ±2 mm of the bone resection thickness measured intra-operatively. METHODS: Forty-one patient-specific TKAs were examined: 25 performed with Visionaire® technology and 16 with OtisMed® system. PSI accuracy was analysed comparing the resected bone thicknesses in the femoral and tibial cuts with pre-operatively planned resections. To determine pre-operative planning precision, the thickness values reported by the PSI planning were subtracted from the values reported intra-operatively by the calliper. RESULTS: The mean absolute differences between pre-operatively planned resections and corresponding intra-operative thickness measurements ranged from a minimum of 2.6 mm (SD 0.8) to a maximum of 3.6 mm (SD 1.3) in all three anatomical planes in both groups. In every plane, the mean absolute discrepancies between planned resections and measured cuts differed significantly from zero (p < 0.0001). The proportion of differences within ±2 mm between intra-operative measured resections and planned PSI cuts occurred in more than 90 % of the cohort for femoral distal resections. Less precision was reported for the femoral posterior medial cuts (70.7 % within ±2 mm) and the tibial cuts (70.7 % on the medial, 75.6 % on the lateral side). Prosthetic component alignment on the coronal and transverse planes resulted in considerable deviations from the pre-operative planning. CONCLUSION: The two examined PSI technologies were accurate in femoral distal cuts, determining acceptable femoral component placement on the coronal plane. Posterior femoral and tibial cuts were less precise. Deviations from the pre-operative resection planning were reported in every plane. Inaccuracy was explained by ambiguous custom-made jigs placement on the bony surface. LEVEL OF EVIDENCE: III.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/standards , Femur/anatomy & histology , Femur/surgery , Knee Prosthesis , Tibia/anatomy & histology , Tibia/surgery , Aged , Female , Humans , Male , Surgery, Computer-Assisted/methods
2.
Knee Surg Sports Traumatol Arthrosc ; 23(7): 2074-80, 2015 Jul.
Article in English | MEDLINE | ID: mdl-24682516

ABSTRACT

PURPOSE: Concerns exist regarding prosthetic positioning and post-operative limb alignment in unicompartmental knee arthroplasty (UKA). In this study, we hypothesized deviations of the post-op anatomical femoro-tibial angle (aFTA) and the tibial component alignment to be factors influencing UKA survivorship. Moreover, by a comparison between all-poly and metal back UKAs, we hypothesized that prosthetic design plays a role in implant survivorship. METHODS: One hundred ninety-five medial UKAs were performed on 176 patients by two experienced surgeons and one low-UKA user. One hundred and forty-seven UKAs were included in the study: 72 all-poly and 75 metal back. Measurements were performed on radiographs: mechanical femoro-tibial angle, Cartier angle, aFTA and tibial posterior slope (PS) on pre-op radiographs; femoral and tibial component varus/valgus, aFTA and tibial component PS on post-op radiographs. RESULTS: At an average follow-up of 61 months (min. 30, max. 107), 147 UKAs were evaluated: The reported survivorship rate was 93.1 %. Eleven implants underwent revision: ten all-poly and one metal back. No differences were reported between the two groups in the radiographic measurements. Significant radiographic differences were reported between revised and not revised UKAs: Revised UKAs were associated with overcorrection of the pre-op Cartier angle and under correction of pre-op aFTA. Most of revised UKAs were performed by the low-volume UKA surgeon. CONCLUSIONS: Surgeon's experience is essential to achieve good results in UKA: Preserving the tibial epiphyseal axis and avoiding excessive or insufficient corrections of the pre-operative limb alignment are predictor of successful replacement, while prosthetic designs, models and fixation geometry do not affect UKA outcome. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Clinical Competence , Knee Prosthesis , Prosthesis Design , Aged , Arthroplasty, Replacement, Knee/methods , Female , Femur/diagnostic imaging , Femur/surgery , Humans , Male , Metals , Polyethylenes , Radiography , Reoperation , Retrospective Studies , Tibia/diagnostic imaging , Tibia/surgery