Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-35627347

ABSTRACT

An international comparison of continuous monitors measuring radon activity concentration was performed to validate the traceability of the European radon calibration facilities. It was carried out by comparing the secondary standards used by these previous facilities, ranging from 100 Bq·m-3 to 300 Bq·m-3. Secondary standards were individually compared to a secondary reference device previously calibrated in a reference radon atmosphere traceable to a primary standard. The intercomparison was organized by the National Institute for Nuclear, Chemical, and Biological Protection (SUJCHBO) in the period from October 2019 to April 2020 within the European Metrology Program for Innovation and Research (EMPIR), JRP-Contract 16ENV10 MetroRADON. Eight European laboratories participated in this study. The results of the experiment are presented and discussed.


Subject(s)
Air Pollutants, Radioactive , Radiation Monitoring , Radon , Air Pollutants, Radioactive/analysis , Calibration , Radiation Monitoring/methods , Radon/analysis , Reference Standards
2.
Article in English | MEDLINE | ID: mdl-34831904

ABSTRACT

An interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m3, the variation was about 4% for a level of confidence of approximately 95% (k=2). For lower exposure levels, the variation increased to about 6%.


Subject(s)
Air Pollutants, Radioactive , Radiation Monitoring , Radiation Protection , Radon , Air Pollutants, Radioactive/analysis , Calibration , Humans , Radon/analysis
3.
Radiat Prot Dosimetry ; 191(2): 188-191, 2020 Nov 27.
Article in English | MEDLINE | ID: mdl-33120409

ABSTRACT

Measurements of activity concentration of radon gas and radon decay products were carried out in several workplaces including schools, radium spas, swimming pools, water treatment plants, caves and former mines. Based on these measurements, annual effective doses to workers were estimated and values of the equilibrium factor, F, were calculated. This paper describes the different approaches used to estimate the annual effective dose based on the dose coefficients recommended by the International Commission on Radiological Protection. Using the measured F values as opposed to the default F value of 0.4 changed the doses by about 5-95% depending mainly upon the ventilation conditions of the workplace.


Subject(s)
Air Pollutants, Radioactive , Occupational Exposure , Radiation Monitoring , Radon , Air Pollutants, Radioactive/analysis , Humans , Occupational Exposure/analysis , Radon/analysis , Radon Daughters , Workplace
4.
Article in English | MEDLINE | ID: mdl-32183418

ABSTRACT

The National Institute for Nuclear, Biological, and Chemical Protection, under the European project 16ENV10 MetroRADON (the European metrology program for innovation and research, EMPIR), has developed unique equipment for the testing of measuring devices at low-level radon activity concentrations. The equipment consists particularly of an airtight low-level radon chamber (LLRCH) with an inner volume of 324 liters; a Rn-222 type RF 5 flow-through source with a Ra-226 activity of 4.955 kBq developed by Czech Metrological Institute within the above-mentioned project; and a pressure vessel as a radon-free air source. The mass flow controller of the Bronkhorst EL-Flow type is a part of the apparatus and ensures the requested airflow through the radon source-partialized if necessary-through the chamber. The homogeneity of the atmosphere in the chamber is ensured by means of a continuously regulated fan (airflows in the range of 0.1-3.5 m·s-1 can be established). Another important chamber component is the measuring device of climatic conditions, since temperature, air pressure, and relative humidity must be determined. The construction of the equipment allows the time-stable radon activity concentration to be maintained at a precise level for several days. Radon concentration values can be arbitrarily and continuously set in the range from 100 Bq·m-3 to 300 Bq·m-3.


Subject(s)
Radiation Monitoring , Radon/analysis , Air Pollutants, Radioactive/analysis , Air Pollution, Indoor/analysis , Atmosphere
SELECTION OF CITATIONS
SEARCH DETAIL
...