Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Am J Crit Care ; 23(1): 40-8, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24382616

ABSTRACT

BACKGROUND: The effectiveness of simulation-based training of critical care nurses in sterile techniques has not been determined. OBJECTIVE: To evaluate the effectiveness of simulation-based training of critical care nurses to use sterile techniques during central vein catheterization and the effect of such training on infection rates. METHODS: A prospective controlled study with 12-month observational follow-up to assess the rate of catheter-related bloodstream infections in a 23-bed medical, surgical, neurological critical care unit. RESULTS: Forty-six critical care nurses completed assessment and training in sterile technique skills in the simulation laboratory. Performance scores at baseline were poor: median scores in each category ranging from 0 to 2 out of a maximum score of 4 and a median total score of 7 out of a maximum score of 24. After simulation-based training, nurses' median scores in each ST category and their total scores improved significantly, with the median total score increasing to 23 (P < .01; median difference, 15; 95% CI, 14-16). After completion of the simulation-based training intervention, the mean infection rate in the unit was reduced by 85% from 2.61 to 0.4 infections per 1000 catheter-days (P = .02). The incidence rate-ratio derived from the Poisson regression (0.15; 95% CI, 0.03-0.78) indicates an 85% reduction in the incidence of catheter-related bloodstream infections in the unit after the intervention. CONCLUSION: Simulation-based training of critical care nurses in sterile technique is an important component in the strategy to reduce the occurrence of such infections and promote patient safety.


Subject(s)
Catheter-Related Infections/prevention & control , Catheterization, Central Venous/nursing , Critical Care Nursing/education , Patient Safety/standards , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/standards , Computer Simulation , Critical Care Nursing/methods , Critical Care Nursing/standards , Humans , Incidence , Inservice Training/methods , Manikins , Poisson Distribution , Program Evaluation , Prospective Studies , Sterilization/methods , Sterilization/standards
2.
J Crit Care ; 28(4): 433-41, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23265291

ABSTRACT

PURPOSE: Ventilator weaning protocols can improve clinical outcomes, but their impact may vary depending on intensive care unit (ICU) structure, staffing, and acceptability by ICU physicians. This study was undertaken to examine their relationship. DESIGN/METHODS: We prospectively examined outcomes of 102 mechanically ventilated patients for more than 24 hours and weaned using nurse-driven protocol-directed approach (nurse-driven group) in an intensivist-led ICU with low respiratory therapist staffing and compared them with a historic control of 100 patients who received conventional physician-driven weaning (physician-driven group). We administered a survey to assess ICU physicians' attitude. RESULTS: Median durations of mechanical ventilation (MV) in the nurse-driven and physician-driven groups were 2 and 4 days, respectively (P = .001). Median durations of ICU length of stay (LOS) in the nurse-driven and physician-driven groups were 5 and 7 days, respectively (P = .01). Time of extubation was 2 hours and 13 minutes earlier in the nurse-driven group (P < .001). There was no difference in hospital LOS, hospital mortality, rates of ventilator-associated pneumonia, or reintubation rates between the 2 groups. We identified 4 independent predictors of weaning duration: nurse-driven weaning, Acute Physiology and Chronic Health Evaluation II score, vasoactive medications use, and blood transfusion. Intensive care unit physicians viewed this protocol implementation positively (mean scores, 1.59-1.87 on a 5-point Likert scale). CONCLUSIONS: A protocol for liberation from MV driven by ICU nurses decreased the duration of MV and ICU LOS in mechanically ventilated patients for more than 24 hours without adverse effects and was well accepted by ICU physicians.


Subject(s)
Attitude of Health Personnel , Clinical Protocols , Intensive Care Units , Outcome and Process Assessment, Health Care , Physicians/psychology , Ventilator Weaning/methods , Ventilator Weaning/nursing , APACHE , Aged , Blood Transfusion/statistics & numerical data , Case-Control Studies , Chi-Square Distribution , Female , Hospital Mortality , Humans , Male , Middle Aged , Proportional Hazards Models , Prospective Studies , Respiration, Artificial , Statistics, Nonparametric , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...