Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
NMR Biomed ; 31(6): e3905, 2018 06.
Article in English | MEDLINE | ID: mdl-29578260

ABSTRACT

Exercise studies investigating the metabolic response of calf muscles using 31 P MRS are usually performed with a single knee angle. However, during natural movement, the distribution of workload between the main contributors to force, gastrocnemius and soleus is influenced by the knee angle. Hence, it is of interest to measure the respective metabolic response of these muscles to exercise as a function of knee angle using localized spectroscopy. Time-resolved multivoxel 31 P MRS at 7 T was performed simultaneously in gastrocnemius medialis and soleus during rest, plantar flexion exercise and recovery in 12 healthy volunteers. This experiment was conducted with four different knee angles. PCr depletions correlated negatively with knee angle in gastrocnemius medialis, decreasing from 79±14 % (extended leg) to 35±23 %(∼40°), and positively in soleus, increasing from 20±21 % to 36±25 %; differences were significant. Linear correlations were found between knee angle and end-exercise PCr depletions in gastrocnemius medialis (R2 =0.8) and soleus (R2 =0.53). PCr recovery times and end-exercise pH changes that correlated with PCr depletion were consistent with the literature in gastrocnemius medialis and differences between knee angles were significant. These effects were less pronounced in soleus and not significant for comparable PCr depletions. Maximum oxidative capacity calculated for all knee angles was in excellent agreement with the literature and showed no significant changes between different knee angles. In conclusion, these findings confirm that plantar flexion exercise with a straight leg is a suitable paradigm, when data are acquired from gastrocnemius only (using either localized MRS or small surface coils), and that activation of soleus requires the knee to be flexed. The present study comprises a systematic investigation of the effects of the knee angle on metabolic parameters, measured with dynamic multivoxel 31 P MRS during muscle exercise and recovery, and the findings should be used in future study design.


Subject(s)
Exercise/physiology , Knee Joint/physiology , Magnetic Resonance Spectroscopy , Phosphorus/chemistry , Range of Motion, Articular/physiology , Adult , Female , Humans , Hydrogen-Ion Concentration , Linear Models , Male , Oxidation-Reduction , Phosphocreatine/metabolism
2.
Magn Reson Med ; 77(3): 921-927, 2017 03.
Article in English | MEDLINE | ID: mdl-26914656

ABSTRACT

PURPOSE: Separate measurements are required when investigating multiple exercising muscles with singlevoxel-localized dynamic 31 P-MRS. With multivoxel spectroscopy, 31 P-MRS time-series spectra are acquired from multiple independent regions during one exercise-recovery experiment with the same time resolution as for singlevoxel measurements. METHODS: Multiple independently selected volumes were localized using temporally interleaved semi-LASER excitations at 7T. Signal loss caused by mutual saturation from shared excitation or refocusing slices was quantified at partial and full overlap, and potential contamination was investigated in phantom measurements. During an exercise-recovery experiment both gastrocnemius medialis and soleus of two healthy volunteers were measured using multivoxel acquisitions with a total TR of 6 s, while avoiding overlap of excitation slices. RESULTS: Signal reduction by shared adiabatic refocusing slices selected 1 s after the preceding voxel was between 10% (full overlap) and 20% (half overlap), in a phantom measurement. In vivo data were acquired from both muscles within the same exercise experiment, with 13-18% signal reduction. Spectra show phosphocreatine, inorganic phosphate, adenosine-triposphate, phosphomonoesters, and phosphodiesters. CONCLUSION: Signal decrease was relatively low compared to the 2-fold increase in information. The approach could help to improve the understanding in metabolic research and is applicable to other organs and nuclei. Magn Reson Med 77:921-927, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Subject(s)
Algorithms , Exercise/physiology , Magnetic Resonance Spectroscopy/methods , Muscle, Skeletal/physiology , Phosphorus Compounds/metabolism , Phosphorus Isotopes/pharmacokinetics , Female , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Male , Molecular Imaging/methods , Radiopharmaceuticals/pharmacokinetics , Reproducibility of Results , Sensitivity and Specificity
3.
Sci Rep ; 6: 32037, 2016 08 26.
Article in English | MEDLINE | ID: mdl-27562396

ABSTRACT

(31)P magnetic resonance spectroscopy (MRS) is widely used for non-invasive investigation of muscle metabolism dynamics. This study aims to extend knowledge on parameters derived from these measurements in detail and comprehensiveness: proton (H(+)) efflux, buffer capacity and the contributions of glycolytic (L) and oxidative (Q) rates to ATP synthesis were calculated from the evolutions of phosphocreatine (PCr) and pH. Data are reported for two muscles in the human calf, for each subject and over a wide range of exercise intensities. 22 subjects performed plantar flexions in a 7T MR-scanner, leading to PCr changes ranging from barely noticeable to almost complete depletion, depending on exercise protocol and muscle studied by localized MRS. Cytosolic buffer capacity was quantified for the first time non-invasively and individually, as was proton efflux evolution in early recovery. Acidification started once PCr depletion reached 60-75%. Initial and end-exercise L correlated with end-exercise levels of PCr and approximately linear with pH. Q calculated directly from PCr and pH derivatives was plausible, requiring fewer assumptions than the commonly used ADP-model. In conclusion, the evolution of parameters describing cellular energy metabolism was measured over a wide range of exercise intensities, revealing a relatively complete picture of muscle metabolism.


Subject(s)
Adenosine Triphosphate/metabolism , Exercise/physiology , Magnetic Resonance Spectroscopy/methods , Muscle, Skeletal/metabolism , Protons , Female , Humans , Male
4.
MAGMA ; 28(5): 493-501, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25894813

ABSTRACT

OBJECTIVES: This study demonstrates the applicability of semi-LASER localized dynamic (31)P MRS to deeper lying areas of the exercising human soleus muscle (SOL). The effect of accurate localization and high temporal resolution on data specificity is investigated. MATERIALS AND METHODS: To achieve high signal-to-noise ratio (SNR) at a temporal resolution of 6 s, a custom-built human calf coil array was used at 7T. The kinetics of phosphocreatine (PCr) and intracellular pH were quantified separately in SOL and gastrocnemius medialis (GM) muscle of nine volunteers, during rest, plantar flexion exercise, and recovery. RESULTS: The average SNR of PCr at rest was [Formula: see text] in SOL ([Formula: see text] in GM). End exercise PCr depletion in SOL ([Formula: see text] %) was far lower than in GM ([Formula: see text] %). The pH in SOL increased rapidly and, in contrast to GM, remained elevated until the end of exercise. CONCLUSION: (31)P MRS in single-shots every 6 s localized in the deeper-lying SOL enabled quantification of PCr recovery times at low depletions and of fast pH changes, like the initial rise. Both high temporal resolution and accurate spatial localization improve specificity of Pi and, thus, pH quantification by avoiding multiple, and potentially indistinguishable sources for changing the Pi peak shape.


Subject(s)
Exercise/physiology , Lasers , Magnetic Resonance Spectroscopy/instrumentation , Muscle, Skeletal/physiology , Phosphocreatine/metabolism , Equipment Design , Equipment Failure Analysis , Female , Humans , Male , Phosphorus Isotopes/pharmacokinetics , Reproducibility of Results , Sensitivity and Specificity , Young Adult
5.
Magn Reson Med ; 73(6): 2376-89, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25046817

ABSTRACT

PURPOSE: To enhance sensitivity and coverage for calf muscle studies, a novel, form-fitted, three-channel phosphorus-31 ((31) P), two-channel proton ((1) H) transceiver coil array for 7 T MR imaging and spectroscopy is presented. METHODS: Electromagnetic simulations employing individually generated voxel models were performed to design a coil array for studying nonpathological muscle metabolism. Static phase combinations of the coil elements' transmit fields were optimized based on homogeneity and efficiency for several voxel models. The best-performing design was built and tested both on phantoms and in vivo. RESULTS: Simulations revealed that a shared conductor array for (31) P provides more robust interelement decoupling and better homogeneity than an overlap array in this configuration. A static B1 (+) shim setting that suited various calf anatomies was identified and implemented. Simulations showed that the (31) P array provides signal-to-noise ratio (SNR) benefits over a single loop and a birdcage coil of equal radius by factors of 3.2 and 2.6 in the gastrocnemius and by 2.5 and 2.0 in the soleus muscle. CONCLUSION: The performance of the coil in terms of B1 (+) and achievable SNR allows for spatially localized dynamic (31) P spectroscopy studies in the human calf. The associated higher specificity with respect to nonlocalized measurements permits distinguishing the functional responses of different muscles.


Subject(s)
Image Enhancement/instrumentation , Leg , Magnetic Resonance Imaging/instrumentation , Muscle, Skeletal/anatomy & histology , Adult , Computer Simulation , Equipment Design , Female , Healthy Volunteers , Humans , Male , Phantoms, Imaging , Phosphorus Isotopes
SELECTION OF CITATIONS
SEARCH DETAIL
...