1.
Phys Rev Lett ; 124(23): 232502, 2020 Jun 12.
Article in English | MEDLINE | ID: mdl-32603173

ABSTRACT

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden nonunique ß-decay transition ^{137}Xe(7/2^{-})→^{137}Cs(7/2^{+}). The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultralow background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal to background ratio of more than 99 to 1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden nonunique ß-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

2.
Rev Sci Instrum ; 91(3): 035117, 2020 Mar 01.
Article in English | MEDLINE | ID: mdl-32259974

ABSTRACT

We report on the design, construction, and characterization of a 10 m-long high-performance magnetic shield for very long baseline atom interferometry. We achieve residual fields below 4 nT and longitudinal inhomogeneities below 2.5 nT/m over 8 m along the longitudinal direction. Our modular design can be extended to longer baselines without compromising the shielding performance. Such a setup constrains biases associated with magnetic field gradients to the sub-pm/s2 level in atomic matterwave accelerometry with rubidium atoms and paves the way toward tests of the universality of free fall with atomic test masses beyond the 10-13 level.

3.
Phys Rev Lett ; 123(14): 143003, 2019 Oct 04.
Article in English | MEDLINE | ID: mdl-31702217

ABSTRACT

We report results of a new technique to measure the electric dipole moment of ^{129}Xe with ^{3}He comagnetometry. Both species are polarized using spin-exchange optical pumping, transferred to a measurement cell, and transported into a magnetically shielded room, where SQUID magnetometers detect free precession in applied electric and magnetic fields. The result from a one week measurement campaign in 2017 and a 2.5 week campaign in 2018, combined with detailed study of systematic effects, is d_{A}(^{129}Xe)=(1.4±6.6_{stat}±2.0_{syst})×10^{-28} e cm. This corresponds to an upper limit of |d_{A}(^{129}Xe)|<1.4×10^{-27} e cm (95% C.L.), a factor of 5 more sensitive than the limit set in 2001.

4.
Phys Rev Lett ; 123(16): 161802, 2019 Oct 18.
Article in English | MEDLINE | ID: mdl-31702371

ABSTRACT

A search for neutrinoless double-ß decay (0νßß) in ^{136}Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between 0νßß and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4±3.0%, and the energy resolution of the detector at the Q value of ^{136}Xe 0νßß has been improved from σ/E=1.23% to 1.15±0.02% with the upgraded detector. Accounting for the new data, the median 90% confidence level 0νßß half-life sensitivity for this analysis is 5.0×10^{25} yr with a total ^{136}Xe exposure of 234.1 kg yr. No statistically significant evidence for 0νßß is observed, leading to a lower limit on the 0νßß half-life of 3.5×10^{25} yr at the 90% confidence level.

5.
Phys Rev Lett ; 120(7): 072701, 2018 Feb 16.
Article in English | MEDLINE | ID: mdl-29542972

ABSTRACT

Results from a search for neutrinoless double-beta decay (0νßß) of ^{136}Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to σ/E=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between 0νßß and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level 0νßß half-life sensitivity after combining with the full data set acquired before the upgrade has increased twofold to 3.7×10^{25} yr. No statistically significant evidence for 0νßß is observed, leading to a lower limit on the 0νßß half-life of 1.8×10^{25} yr at the 90% confidence level.

6.
Rev Sci Instrum ; 87(11): 115116, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910557

ABSTRACT

A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of 10-29 e ⋅ cm by using polarized "magic" momentum 0.7 GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the standard model at the scale of 3000 TeV.

7.
Rev Sci Instrum ; 85(9): 095114, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25273779

ABSTRACT

We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope (136)Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight mass spectroscopy for positive identification of the barium decay product.

8.
Rev Sci Instrum ; 85(7): 075106, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25085172

ABSTRACT

A versatile and portable magnetically shielded room with a field of (700 ± 200) pT within a central volume of 1 m × 1 m × 1 m and a field gradient less than 300 pT/m, achieved without any external field stabilization or compensation, is described. This performance represents more than a hundredfold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus. This has implications for developments of magnetometry beyond the femto-Tesla scale in, for example, biomagnetism, geosciences, and security applications and in general low-field nuclear magnetic resonance (NMR) measurements.

9.
Phys Rev Lett ; 109(3): 032505, 2012 Jul 20.
Article in English | MEDLINE | ID: mdl-22861843

ABSTRACT

We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3) kg(-1) yr(-1) keV(-1) in the ±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νßß)(136Xe)>1.6×10(25) yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.

10.
Phys Rev Lett ; 107(21): 212501, 2011 Nov 18.
Article in English | MEDLINE | ID: mdl-22181874

ABSTRACT

We report the observation of two-neutrino double-beta decay in (136)Xe with T(1/2) = 2.11 ± 0.04(stat) ± 0.21(syst) × 10(21) yr. This second-order process, predicted by the standard model, has been observed for several nuclei but not for (136)Xe. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrinoless double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

11.
Rev Sci Instrum ; 82(10): 105114, 2011 Oct.
Article in English | MEDLINE | ID: mdl-22047336

ABSTRACT

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon time projection chamber of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute of xenon gas with 750 Torr differential pressure.

12.
Phys Rev Lett ; 103(8): 081602, 2009 Aug 21.
Article in English | MEDLINE | ID: mdl-19792714

ABSTRACT

A clock comparison experiment, analyzing the ratio of spin precession frequencies of stored ultracold neutrons and 199Hg atoms, is reported. No daily variation of this ratio could be found, from which is set an upper limit on the Lorentz invariance violating cosmic anisotropy field b perpendicular < 2 x 10(-20) eV (95% C.L.). This is the first limit for the free neutron. This result is also interpreted as a direct limit on the gravitational dipole moment of the neutron |gn| < 0.3 eV/c2 m from a spin-dependent interaction with the Sun. Analyzing the gravitational interaction with the Earth, based on previous data, yields a more stringent limit |gn| < 3 x 10(-4) eV/c2 m.

13.
Rev Sci Instrum ; 79(4): 045101, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18447546

ABSTRACT

We describe a sensor for the measurement of thin dielectric layers capable of operation in a variety of environments. The sensor is obtained by microfabricating a capacitor with interleaved aluminum fingers, exposed to the dielectric to be measured. In particular, the device can measure thin layers of solid frozen from a liquid or gaseous medium. Sensitivity to single atomic layers is achievable in many configurations and, by utilizing fast, high sensitivity capacitance readout in a feedback system onto environmental parameters; coatings of few layers can be dynamically maintained. We discuss the design, readout, and calibration of several versions of the device optimized in different ways. We specifically dwell on the case in which atomically thin solid xenon layers are grown and stabilized, in cryogenic conditions, from a liquid xenon bath.

14.
Phys Rev Lett ; 99(26): 262502, 2007 Dec 31.
Article in English | MEDLINE | ID: mdl-18233572

ABSTRACT

A measurement of the production of ultracold neutrons from velocity-selected cold neutrons on gaseous and solid deuterium targets is reported. The expected energy dependence for two-particle collisions with well defined neutron and Maxwell-Boltzmann distributed molecular velocities is found for the gas target. The solid target data agree in shape with the phonon density-of-states curve and provide strong evidence for the phonon model including multiphonon excitations.

15.
Phys Rev Lett ; 95(18): 182502, 2005 Oct 28.
Article in English | MEDLINE | ID: mdl-16383898

ABSTRACT

The total scattering cross sections for slow neutrons with energies in the range 100 neV to 3 meV for solid ortho-2H2 at 18 and 5 K, frozen from the liquid, have been measured. The 18 K cross sections are found to be in excellent agreement with theoretical expectations and for ultracold neutrons dominated by thermal up scattering. At 5 K the total scattering cross sections are found to be dominated by the crystal defects originating in temperature induced stress but not deteriorated by temperature cycles between 5 and 10 K.

16.
Phys Rev Lett ; 94(21): 212502, 2005 Jun 03.
Article in English | MEDLINE | ID: mdl-16090315

ABSTRACT

The total scattering cross sections for slow neutrons with energies E in the range 300 neV to 3 meV for gaseous and liquid ortho-2H2 have been measured. The cross sections for 2H2 gas are found to be in excellent agreement with both the Hamermesh and Schwinger and the Young and Koppel models. For liquid 2H(2), we confirm the existing experimental data in the cold neutron range and the discrepancy with the gas models. We find a clear 1 / square root[E'] dependence at low energies for both states. A simple explanation for the liquid 2H2 cross section is offered.

17.
J Res Natl Inst Stand Technol ; 110(3): 173-8, 2005.
Article in English | MEDLINE | ID: mdl-27308117

ABSTRACT

For highly sensitive magnetic measurements, e.g., a measurement of the neutron electric dipole moment (EDM), the magnetic field has to be stable in time on a level below picoTesla. One of several measures we employ to achieve this uses an external field coil system which can stabilize the ambient external field at a predefined value. Here we report on the construction and characterization of such a system in the magnetic test facility at PSI. The system actively stabilizes the field along the axis of the EDM experiment by means of four coils in a Helmholtz-like configuration. Additional coils serve to compensate for transverse ambient field components. Because of the long integration times in the EDM experiment (about 100 s or more) only slow disturbances have to be corrected for. The performance of the system has been measured using static and moving magnetic sources and suppression factors in excess of 200 have been observed.

18.
J Res Natl Inst Stand Technol ; 110(3): 283-8, 2005.
Article in English | MEDLINE | ID: mdl-27308137

ABSTRACT

We report the results of test measurements aimed at determining the performances of (6)Li doped glass scintillators for the detection of ultra-cold neutrons. Four types of scintillators, GS1, GS3, GS10 and GS20, which differ by their (6)Li concentrations, have been tested. The signal to background separation is fully acceptable. The relative detection efficiencies have been determined as a function of the neutron velocity. We find that GS10 has a higher efficiency than the others for the detection of neutrons with velocities below 7 m/s. Two pieces of scintillators have been irradiated with a high flux of cold neutrons to test the radiation hardness of the glasses. No reduction in the pulse height has been observed up to an absorbed neutron dose of 1 × 10(13) cm(-3).

19.
J Res Natl Inst Stand Technol ; 110(4): 351-6, 2005.
Article in English | MEDLINE | ID: mdl-27308149

ABSTRACT

A new type of per-fluorinated polymer, "Low Temperature Fomblin," has been tested as a wall coating in an ultracold neutron (UCN) storage experiment using a gravitational storage system. The data show a UCN reflection loss coefficient η as low as ≈ 5 × 10(-6) in the temperature range 105 K to 150 K. We plan to use this oil in a new type of neutron lifetime measurement, where a bellows system ("accordion") enables to vary the trap size in a wide range while the total surface area and distribution of surface area over height remain constant. These unique characteristics, in combination with application of the scaling technique developed by W. Mampe et al. in 1989, ensure exact linearity for the extrapolation from inverse storage lifetimes to the inverse neutron lifetime. Linearity holds for any energy dependence of loss coefficient µ(E). Using the UCN source at the Institut Laue Langevin we expect to achieve a lifetime precision below ±1 s.

20.
J Res Natl Inst Stand Technol ; 110(4): 491-4, 2005.
Article in English | MEDLINE | ID: mdl-27308173

ABSTRACT

Solid deuterium (sD2) will be used for the production of ultra-cold neutrons (UCN) in a new generation of UCN sources. Scattering cross sections of UCN in sD2 determine the source yield but until now have not been investigated. We report first results from transmission and scattering experiments with cold, very cold and ultra-cold neutrons on sD2 along with light transmission and Raman scattering studies showing the influence of the sD2 crystal properties.