1.
Gastroenterol Res Pract ; 2014: 691532, 2014.
Article in English | MEDLINE | ID: mdl-25574163

ABSTRACT

Transcutaneous intraluminal impedance measurement (TIIM) is a new method to cutaneously measure gastric contractions by assessing the attenuation dynamics of a small oscillating voltage emitted by a battery-powered ingestible capsule retained in the stomach. In the present study, we investigated whether TIIM can reliably assess gastric motility in acute canine models. Methods. Eight mongrel dogs were randomly divided into 2 groups: half received an active TIIM pill and half received an identically sized sham capsule. After 24-hour fasting and transoral administration of the pill (active or sham), two force transducers (FT) were sutured onto the antral serosa at laparotomy. After closure, three standard cutaneous electrodes were placed on the abdomen, registering the transluminally emitted voltage. Thirty-minute baseline recordings were followed by pharmacological induction of gastric contractions using neostigmine IV and another 30-minute recording. Normalized one-minute baseline and post-neostigmine gastric motility indices (GMIs) were calculated and Pearson correlation coefficients (PCCs) between cutaneous and FT GMIs were obtained. Statistically significant GMI PCCs were seen in both baseline and post-neostigmine states. There were no significant GMI PCCs in the sham capsule test. Further chronic animal studies of this novel long-term gastric motility measurement technique are needed before testing it on humans.

2.
Gastrointest Endosc ; 77(2): 272-9, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23317692

ABSTRACT

BACKGROUND: Capsule endoscopy is a noninvasive method for examining the small intestine. Recently, this method has been used to visualize the colon. However, the capsule often tumbles in the wider colon lumen, resulting in potentially missed pathology. In addition, the capsule does not have the ability to distend collapsed segments of the organ. Self-stabilizing capsule endoscopy is a new method of visualizing the colon without tumbling and with the ability to passively distend colon walls. OBJECTIVE: To quantitatively compare the detection rate of intraluminal suture marker lesions for colonoscopy by using a custom-modified, self-stabilizing capsule endoscope (SCE); an unmodified capsule endoscope (CE) of the same brand; and a standard colonoscope. DESIGN: Four mongrel dogs underwent laparotomy and the implantation of 5 to 8 suture markers to approximate colon lesions. Each dog had both capsule endoscopy and self-stabilizing capsule endoscopy, administered consecutively in random order. In each case, the capsule was inserted endoscopically into the proximal lumen of the colon followed by pharmacologically induced colon peristalsis to propel it distally through the colon. Blinded standard colonoscopy was performed by an experienced gastroenterologist after the capsule endoscopies. SETTING: Experimental study in a live canine model. SUBJECTS: Four dogs. INTERVENTION: Laparotomy, capsule endoscopy, colonoscopy. MAIN OUTCOME MEASUREMENTS: Comparison of the marker detection rate of the SCE to that of the unmodified MiroCam CE and a colonoscope. RESULTS: The average percentages of the marker detection rate for unmodified capsule endoscopy, self-stabilizing capsule endoscopy, and colonoscopy, respectively, were 31.1%, 86%, and 100% (P < .01), with both self-stabilizing capsule endoscopy and colonoscopy performing significantly better than the unmodified capsule endoscopy. LIMITATIONS: Acute canine model, suture markings poorly representative of epithelial polyps, limited number of animals. CONCLUSION: The proposed self-stabilizing capsule endoscope delivered a significant improvement in detection rates of colon suture markings when compared with the unmodified capsule endoscope.


Subject(s)
Capsule Endoscopes , Capsule Endoscopy/instrumentation , Colonic Diseases/diagnosis , Animals , Capsule Endoscopy/methods , Colonoscopes , Colonoscopy , Disease Models, Animal , Dogs , Equipment Design , Female , Pilot Projects , Random Allocation , Sutures
3.
World J Gastroenterol ; 18(32): 4270-7, 2012 Aug 28.
Article in English | MEDLINE | ID: mdl-22969189

ABSTRACT

AIM: To investigate the performance of a new software-based colonoscopy quality assessment system. METHODS: The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. RESULTS: Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P < 0.01). Withdrawal times during which no polyps were removed ranged from 4-12 min. The median quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3.1-3.68] and 3.00 (IQR, 2.33-3.67) respectively for all colonoscopy video samples. The automated rating revealed a strong correlation with the reviewer's rating (ρ coefficient= 0.65, P = 0.01). There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating (Spearman r coefficient= 0.59, P = 0.03). There was no correlation of automated overall quality rating with mean endoscopists image quality rating (Spearman r coefficient= 0.41, P = 0.15). CONCLUSION: The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments. Further study is required to validate this approach.


Subject(s)
Colonoscopy/methods , Computer Systems/standards , Diagnosis, Computer-Assisted/methods , Early Detection of Cancer/methods , Software/standards , Adenomatous Polyps/diagnosis , Algorithms , Colonic Neoplasms/diagnosis , Humans , Pilot Projects , Quality Assurance, Health Care , Reproducibility of Results
4.
IEEE Trans Med Imaging ; 30(12): 2115-25, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21803680

ABSTRACT

Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel method to visualize the colon without tumbling. The aim of the present study was to comparatively quantify the effect of stabilization of a commercially available nonmodified capsule endoscope (CE) MiroCam and its modified self-stabilizing version in acute canine experiments. Two customized MiroCam CEs were reduced in volume at the nonimaging back-end to allow the attachment of a self-expanding, biocompatible stabilizing device. Four mongrel dogs underwent laparotomy and exteriorization of a 15-cm segment of the proximal descending colon. A single CE, either self-stabilizing or nonmodified was inserted through an incision into the lumen of the colon followed by pharmacologically induced colonic peristalsis. The inserted capsule was propelled distally through the colon and expelled naturally through the anus. Novel signal processing method was developed to quantify the video stabilization based on camera tracking a predetermined target point (locale). The average locale trajectory, the average radius movement of the locale, and the maximum rate of change of the locale for sequential images were significantly lower for the stabilized capsules compared to the nonstabilized ones . The feasibility of self-stabilized capsule endoscopy has been demonstrated in acute canine experiments.


Subject(s)
Capsule Endoscopes , Capsule Endoscopy/methods , Animals , Capsule Endoscopy/instrumentation , Colon, Descending/anatomy & histology , Colon, Descending/physiology , Dogs , Feasibility Studies , Pilot Projects , Signal Processing, Computer-Assisted