1.
J Breath Res ; 16(2)2022 01 07.
Article in English | MEDLINE | ID: mdl-34942609

ABSTRACT

Blood glucose monitoring (BGM) is the most important part of diabetes management. In classical BGM, glucose measurement by test strips involves invasive finger pricking. We present results of a clinical study that focused on a non-invasive approach based on volatile organic compounds (VOCs) in exhaled breath. Main objective was the discovery of markers for prediction of blood glucose levels (BGLs) in diabetic patients. Exhaled breath was measured repeatedly in 60 diabetic patients (30 type 1, 30 type 2) in fasting state and after a standardized meal. Proton transfer reaction time of flight mass spectrometry was used to sample breath every 15 min for a total of 6 h. BGLs were tested in parallel via BGM test strips. VOC signals were plotted against glucose trends for each subject to identify correlations. Exhaled indole (a bacterial metabolite of tryptophan) showed significant mean correlation to BGL (with negative trend) and significant individual correlation in 36 patients. The type of diabetes did not affect this result. Additional experiments of one healthy male subject by ingestion of lactulose and13C-labeled glucose (n= 3) revealed that exhaled indole does not directly originate from food digestion by intestinal microbiota. As indole has been linked to human glucose metabolism, it might be a tentative marker in breath for non-invasive BGM. Clinical studies with greater diversity are required for confirmation of such results and further investigation of metabolic pathways.


Subject(s)
Diabetes Mellitus , Volatile Organic Compounds , Blood Glucose , Blood Glucose Self-Monitoring , Breath Tests/methods , Exhalation , Humans , Indoles , Male , Volatile Organic Compounds/analysis
2.
J Diabetes Sci Technol ; 15(4): 792-800, 2021 07.
Article in English | MEDLINE | ID: mdl-32115999

ABSTRACT

BACKGROUND: The increasing offering of patch-based medical devices is accompanied by growing numbers of reported adverse skin reactions. Procedures for testing leachables according to ISO 10993 may not be optimal for lipophilic substances that can be mobilized on skin by sweat and sebum. We propose an improved extraction method for targeted analysis of leachables using low volumes of a sweat-sebum emulsion. The approach is illustrated by the analysis of isobornylacrylate (IBOA), a compound found in some devices and suspected for allergenic potential. METHOD: Three patch-based products were tested: an implantable device for continuous glucose monitoring (CGM), an intermittently scanned CGM (isCGM) device, and a micro-insulin pump. Quantification of IBOA was performed by gas chromatography and allergenic potential of IBOA levels was assessed by the KeratinoSens cell assay. Different combinations were used for extraction solvent (isopropanol, 5% ethanol-water solution, and sweat-sebum emulsion), extraction volumes (complete immersion vs partial immersion in 2 mm of solvent), and extraction time (3, 5, and 14 days). RESULTS: Isobornylacrylate was only found in the isCGM device. About 20 mg/L IBOA were eluted after 3 days in isopropanol but only about 1 mg/L in ethanol-water. Sweat-sebum emulsion dissolves IBOA better and gives a more stable solution than ethanol-water. Decomposition of IBOA solutions requires adjusted extraction timing or correction of results. In the sweat-sebum extract, IBOA levels were about 20 mg/L after 3 days and about 30 mg/L after 5 days, clearly above the threshold found in the KerationSens assay for keratinocyte activation (10 mg/L). CONCLUSION: Extraction by low volumes of sweat-sebum emulsion can be a superior alternative for the targeted simulating-use assessment of leachables in patch-based medical devices.


Subject(s)
Diabetes Mellitus , Sebum , Acrylates , Blood Glucose , Blood Glucose Self-Monitoring , Camphanes , Emulsions , Humans , Sweat
3.
J Neurosci Methods ; 128(1-2): 159-72, 2003 Sep 30.
Article in English | MEDLINE | ID: mdl-12948559

ABSTRACT

Cu is thought to play an important role in the pathogenesis of several neurodegenerative diseases, such as Wilson's, Alzheimer's, and probably in prion protein diseases like Creutzfeld-Jakob's disease. Until now, no method existed to determine the concentration of this cation in vivo. Here, we present two possible approaches combined with a critical comparison of the results. The successful use of fluorescent ligands for the determination of Ca2+-concentrations in recent years encouraged us to seek a fluorophore which specifically reacts to Cu2+ and to characterize it for our purposes. We found that the emission of TSPP (tetrakis-(4-sulfophenyl)porphine) at an emission wavelength of 645 nm is in vitro highly specific to Cu2+ (apparent dissociation constant Kd=0.43 +/- 0.07 microM at pH 7.4). It does not react with the most common divalent cations in the brain, Ca2+ and Mg2+, unlike most of the other dyes examined. In addition, Zn2+ quenches TSPP fluorescence at a different emission wavelength (605 nm) with a Kd of 50 +/- 2.5 microM (pH 7.0). With these findings, we applied the measurement of Cu with TSPP to a biological system, showing for the first time in vivo that there is release of copper by synaptosomes upon depolarisation. Our findings were validated with a completely independent analytical approach based on ICP-MS (inductively-coupled-plasma mass-spectrometry).


Subject(s)
Copper/analysis , Copper/physiology , Synaptosomes/chemistry , Synaptosomes/metabolism , Animals , Cattle , Cell Membrane Permeability/physiology , Chromaffin Cells/chemistry , Chromaffin Cells/metabolism , Mass Spectrometry/methods , Porphyrins/analysis
4.
Anal Chem ; 74(17): 4334-42, 2002 Sep 01.
Article in English | MEDLINE | ID: mdl-12236340

ABSTRACT

An experimental setup for direct elemental analysis of recycled thermoplasts from consumer electronics by laser-induced plasma spectroscopy (LIPS, or laser-induced breakdown spectroscopy, LIBS) was realized. The combination of a echelle spectrograph, featuring a high resolution with a broad spectral coverage, with multivariate methods, such as PLS, PCR, and variable subset selection via a genetic algorithm, resulted in considerable improvements in selectivity and sensitivity for this complex matrix. With a normalization to carbon as internal standard, the limits of detection were in the ppm range. A preliminary pattern recognition study points to the possibility of polymer recognition via the line-rich echelle spectra. Several experiments at an extruder within a recycling plant demonstrated successfully the capability of LIPS for different kinds of routine on-line process analysis.


Subject(s)
Industrial Waste/prevention & control , Plastics/analysis , Electronics , Equipment Reuse , Industrial Waste/analysis , Lasers , Spectrum Analysis
SELECTION OF CITATIONS