Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chim Acta ; 630(2): 124-30, 2008 Dec 23.
Article in English | MEDLINE | ID: mdl-19012823

ABSTRACT

This paper describes a microfluidic platform for the on-demand generation of multiple aqueous droplets, with varying chemical contents or chemical concentrations, for use in droplet based experiments. This generation technique was developed as a complement to existing techniques of continuous-flow (streaming) and discrete-droplet generation by enabling the formation of multiple discrete droplets simultaneously. Here sets of droplets with varying chemical contents can be generated without running the risk of cross-contamination due to the isolated nature of each supply inlet. The use of pressure pulses to generate droplets in parallel is described, and the effect of droplet size is examined in the context of flow rates and surfactant concentrations. To illustrate this technique, an array of different dye-containing droplets was generated, as well as a set of droplets that displayed a concentration gradient of a fluorescent dye.


Subject(s)
Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Water/chemistry , Oils/chemistry , Surface-Active Agents/chemistry
2.
Electrophoresis ; 28(16): 2904-11, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17640094

ABSTRACT

A new technique for polymer microchannel surface modification, called in-channel atom-transfer radical polymerization, has been developed and applied in the surface derivatization of thermoset polyester (TPE) microdevices with poly(ethylene glycol) (PEG). X-ray photoelectron spectroscopy, electroosmotic flow (EOF), and contact angle measurements indicate that PEG has been grafted on the TPE surface. Moreover, PEG-modified microchannels have much lower and more pH-stable EOF, more hydrophilic surfaces and reduced nonspecific protein adsorption. Capillary electrophoresis separation of amino acid and peptide mixtures in these PEG-modified TPE microchips had good reproducibility. Phosducin-like protein and phosphorylated phosducin-like protein were also separated to measure the phosphorylation efficiency. Our results indicate that PEG-grafted TPE microchips have broad potential application in biomolecular analysis.


Subject(s)
Microfluidic Analytical Techniques/methods , Adsorption , Amino Acids/analysis , Electrophoresis, Microchip/instrumentation , Electrophoresis, Microchip/methods , Electrophoresis, Microchip/statistics & numerical data , Fluorescein-5-isothiocyanate , Fluorescent Dyes , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/statistics & numerical data , Peptides/analysis , Polyesters , Polyethylene Glycols , Proteins/analysis
3.
Lab Chip ; 7(7): 923-6, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17594014

ABSTRACT

Thermoset polyester (TPE) microfluidic devices were previously developed as an alternative to poly(dimethylsiloxane) (PDMS) devices, fabricated similarly by replica molding, yet offering stable surface properties and good chemical compatibility with some organics that are incompatible with PDMS. This paper describes a number of improvements in the fabrication of TPE chips. Specifically, we describe methods to form TPE devices with a thin bottom layer for use with high numerical aperture (NA) objectives for sensitive fluorescence detection and optical manipulation. We also describe plasma-bonding of TPE to glass to create hybrid TPE-glass devices. We further present a simple master-pretreatment method to replace our original technique that required the use of specialized equipment.


Subject(s)
Dimethylpolysiloxanes/chemistry , Microfluidic Analytical Techniques/instrumentation , Microfluidics , Polyesters/chemistry , Silicones/chemistry , Catalysis , Electrochemistry , Equipment Design , Glass , Microscopy, Fluorescence , Models, Theoretical , Osmosis , Silanes/chemistry , Surface Properties
4.
Anal Chem ; 78(19): 6948-54, 2006 Oct 01.
Article in English | MEDLINE | ID: mdl-17007519

ABSTRACT

This paper demonstrates the ability to use capillary electrophoresis (CE) separation coupled with laser-induced fluorescence for analyzing the contents of single femtoliter-volume aqueous droplets. A single droplet was formed using a T-channel (3 microm wide by 3 microm tall) connected to microinjectors, and then the droplet was fluidically moved to an immiscible boundary that isolates the CE channel (50 microm wide by 50 microm tall) from the droplet generation region. Fusion of the aqueous droplet with the immiscible boundary effectively injects the droplet content into the separation channel. In addition to injecting the contents of droplets, we found aqueous samples can be introduced directly into the separation channel by reversibly penetrating and resealing the immiscible partition. Because droplet generation in channels requires hydrophobic surfaces, we have also investigated the advantages to using all hydrophobic channels versus channel systems with patterned hydrophobic and hydrophilic regions. To fabricate devices with patterned surface chemistry, we have developed a simple strategy based on differential wetting to deposit selectively a hydrophilic polymer (poly(styrenesulfonate)) onto desired regions of the microfluidic chip. Finally, we applied our device to the separation of a simple mixture of fluorescein-labeled amino acids contained within a approximately 10-fL droplet.


Subject(s)
Electrophoresis, Capillary/methods , Fluorescence
5.
Biotechniques ; 38(3): 429-46, 2005 Mar.
Article in English | MEDLINE | ID: mdl-15786809

ABSTRACT

This review article describes recent developments in microfluidics, with special emphasis on disposable plastic devices. Included is an overview of the common methods used in the fabrication of polymer microfluidic systems, including replica and injection molding, embossing, and laser ablation. Also described are the different methods by which on-chip operations--such as the pumping and valving of fluid flow, the mixing of different reagents, and the separation and detection of different chemical species--have been implemented in a microfluidic format. Finally, a few select biotechnological applications of microfluidics are presented to illustrate both the utility of this technology and its potential for development in the future.


Subject(s)
Biosensing Techniques/instrumentation , Chemistry Techniques, Analytical/instrumentation , Disposable Equipment , Microarray Analysis/instrumentation , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Biosensing Techniques/methods , Biosensing Techniques/trends , Chemistry Techniques, Analytical/methods , Chemistry Techniques, Analytical/trends , Equipment Design , Equipment Failure Analysis , Microarray Analysis/methods , Microarray Analysis/trends , Microfluidic Analytical Techniques/trends , Technology Assessment, Biomedical
6.
Electrophoresis ; 25(21-22): 3796-804, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15565689

ABSTRACT

With advances in III-V nitride manufacturing processes, high-power light-emitting diode (LED) chips in the blue and UV wavelengths are now commercially available at reasonable cost and can be used as excitation sources in optical sensing. We describe the use of these high-power blue and UV LEDs for sensitive fluorescence detection, including chip-based flow cytometry, capillary electrophoresis (CE), and single-molecule imaging. By using a blue LED with a focusable power of approximately 40 mW as the excitation source for fluorescent beads, we demonstrate a simple chip-based bead sorter capable of enriching the concentration of green fluorescent beads from 63% to 95%. In CE experiments, we show that a mixture of analyte solution containing 30 nM 6-carboxyrhodamine 6G and 10 nM fluorescein can be separated and detected with excellent signal-to-noise ratio (approximately 17 for 10 nM fluorescein) using the collimated emission from a blue LED; the estimated mass detection limit was approximately 200 zmol for fluorescein. We also demonstrated ultrasensitive fluorescence imaging of single rhodamine 123 molecules and individual lambda-DNA molecules. At a small fraction of the cost of an Ar+ laser, high-power blue and UV LEDs are effective alternatives for lasers and arc lamps in fluorescence applications that demand portability, low cost, and convenience.


Subject(s)
Diagnostic Imaging/instrumentation , Lab-On-A-Chip Devices , Light , Optics and Photonics/instrumentation , Cells , Electrophoresis, Capillary , Flow Cytometry , Fluorescence , Ultraviolet Rays
7.
Anal Chem ; 76(16): 4697-704, 2004 Aug 15.
Article in English | MEDLINE | ID: mdl-15307779

ABSTRACT

This paper presents a simple procedure for the fabrication of thermoset polyester (TPE) microfluidic systems and discusses the properties of the final devices. TPE chips are fabricated in less than 3 h by casting TPE resin directly on a lithographically patterned (SU-8) silicon master. Thorough curing of the devices is obtained through the combined use of ultraviolet light and heat, as both an ultraviolet and a thermal initiator are employed in the resin mixture. Features on the order of micrometers and greater are routinely reproduced using the presented procedure, including complex designs and multilayer features. The surface of TPE was characterized using contact angle measurements and X-ray photoelectron spectroscopy (XPS). Following oxygen plasma treatment, the hydrophilicity of the surface of TPE increases (determined by contact angle measurements) and the proportion of oxygen-containing functional groups also increases (determined by XPS), which indicates a correlated increase in the charge density on the surface. Native TPE microchannels support electroosmotic flow (EOF) toward the cathode, with an average electroosmotic mobility of 1.3 x 10(-4) cm(2) V(-1) s(-1) for a 50-microm square channel (20 mM borate at pH 9); following plasma treatment (5 min at 30 W and 0.3 mbar), EOF is enhanced by a factor of 2. This enhancement of the EOF from plasma treatment is stable for days, with no significant decrease noted during the 5-day period that we monitored. Using plasma-treated TPE microchannels, we demonstrate the separation of a mixture of fluorescein-tagged amino acids (glycine, glutamic acid, aspartic acid). TPE devices are up to 90% transparent (for approximately 2-mm-thick sample) to visible light (400-800 nm). The compatibility of TPE with a wide range of solvents was tested over a 24-h period, and the material performed well with acids, bases, alcohols, cyclohexane, n-heptane, and toluene but not with chlorinated solvents (dichloromethane, chloroform).


Subject(s)
Microfluidic Analytical Techniques/methods , Silicon , Microscopy, Electron, Scanning/methods , Osmosis , Polyesters , Surface Properties
8.
Lab Chip ; 3(3): 158-63, 2003 Aug.
Article in English | MEDLINE | ID: mdl-15100767

ABSTRACT

Plastics are increasingly being used for the fabrication of Lab-on-a-Chip devices due to the variety of beneficial material properties, affordable cost, and straightforward fabrication methods available from a range of different types of plastics. Rapid prototyping of polydimethylsiloxane (PDMS) devices has become a well-known process for the quick and easy fabrication of microfluidic devices in the research laboratory; however, PDMS is not always an appropriate material for every application. This paper describes the fabrication of thermoset polyester microfluidic devices and masters for hot embossing using replica molding techniques. Rapid prototyped PDMS molds are convienently used for the production of non-PDMS polymeric devices. The recessed features in the cast polyester can be bonded to a second polyester piece to form an enclosed microchannel. Thermoset polyester can withstand moderate amounts of pressure and elevated temperature; therefore, the cast polyester piece also can be used as a master for embossing polymethylmethacrylate (PMMA) microfluidic systems. Examples of enclosed polyester and PMMA microchannels are presented, and we discuss the electroosmotic properties of both types of channels, which are important for analytical applications such as capillary electrophoresis.


Subject(s)
Dimethylpolysiloxanes/chemistry , Microfluidics/instrumentation , Polyesters/chemistry , Silicones/chemistry , Chemical Phenomena , Chemistry, Physical , Electrophoresis/methods , Microscopy, Electron, Scanning , Polymethyl Methacrylate/chemistry , Pressure , Temperature
SELECTION OF CITATIONS