Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
Add more filters










Publication year range
1.
NPJ Regen Med ; 7(1): 60, 2022 Oct 19.
Article in English | MEDLINE | ID: mdl-36261516

ABSTRACT

Growth plate injuries affecting the pediatric population may cause unwanted bony repair tissue that leads to abnormal bone elongation. Clinical treatment involves bony bar resection and implantation of an interpositional material, but success is limited and the bony bar often reforms. No treatment attempts to regenerate the growth plate cartilage. Herein we develop a 3D printed growth plate mimetic composite as a potential regenerative medicine approach with the goal of preventing limb length discrepancies and inducing cartilage regeneration. A poly(ethylene glycol)-based resin was used with digital light processing to 3D print a mechanical support structure infilled with a soft cartilage-mimetic hydrogel containing chondrogenic cues. Our biomimetic composite has similar mechanical properties to native rabbit growth plate and induced chondrogenic differentiation of rabbit mesenchymal stromal cells in vitro. We evaluated its efficacy as a regenerative interpositional material applied after bony bar resection in a rabbit model of growth plate injury. Radiographic imaging was used to monitor limb length and tibial plateau angle, microcomputed tomography assessed bone morphology, and histology characterized the repair tissue that formed. Our 3D printed growth plate mimetic composite resulted in improved tibial lengthening compared to an untreated control, cartilage-mimetic hydrogel only condition, and a fat graft. However, in vivo the 3D printed growth plate mimetic composite did not show cartilage regeneration within the construct histologically. Nevertheless, this study demonstrates the feasibility of a 3D printed biomimetic composite to improve limb lengthening, a key functional outcome, supporting its further investigation as a treatment for growth plate injuries.

2.
J Biomech ; 134: 111013, 2022 03.
Article in English | MEDLINE | ID: mdl-35245713

ABSTRACT

The aim of this study was to assess the bulk material properties and depth-dependent strain distribution of bovine growth plate cartilage. We hypothesized that both moduli and strain distribution are highly depth-, orientation-, and location-dependent. Bovine proximal tibiae (1-month-old) were sliced along the sagittal and coronal planes to create âˆ¼ 4 mm2 samples. Digital image correlation (DIC) was combined with stress relaxation tests for evaluation of bulk modulus (tangent and equilibrium) and depth-dependent strain distribution. A subset of samples was imaged after Col-F staining as well as histological staining (Safranin-O/Fast Green) to evaluate zonal organization and matrix composition. The mean tangent modulus was 4.25 ± 2.46 MPa while the equilibrium modulus was 0.86 ± 0.46 MPa. No significant differences in moduli were found with respect to orientation (sagittal vs coronal face), but sagittal location within the joint was a significant predictor for tangent modulus. Overall moduli values decreased from the periphery to the midline of the joint. Depth-dependent cellular organization, determined by cell density and shape, was highly variable. This heterogeneity may be a biological toughening mechanism. Peak normalized strains were observed most often in the hypertrophic zone. Modulus was significantly lower in the hypertrophic zone as compared to the resting and proliferative zones. This study is the first to evaluate moduli and strain distribution in intact growth plates as a function of depth, orientation, and anatomic location. Future work with growth plate tissue engineering should consider the location- and depth-dependent nature of the native tissue mechanical properties when designing mimetic constructs.


Subject(s)
Cartilage, Articular , Growth Plate , Animals , Cartilage , Cattle , Stress, Mechanical , Tibia , Tissue Engineering
3.
Biofabrication ; 13(4)2021 09 16.
Article in English | MEDLINE | ID: mdl-34479218

ABSTRACT

Successful 3D scaffold designs for musculoskeletal tissue engineering necessitate full consideration of the form and function of the tissues of interest. When designing structures for engineering cartilage and osteochondral tissues, one must reconcile the need to develop a mechanically robust system that maintains the health of cells embedded in the scaffold. In this work, we present an approach that decouples the mechanical and biochemical needs and allows for the independent development of the structural and cellular niches in a scaffold. Using the highly tuned capabilities of digital light processing-based stereolithography, structures with complex architectures are achieved over a range of effective porosities and moduli. The 3D printed structure is infilled with mesenchymal stem cells and soft biomimetic hydrogels, which are specifically formulated with extracellular matrix analogs and tethered growth factors to provide selected biochemical cues for the guided differentiation towards chondrogenesis and osteogenesis. We demonstrate the ability to utilize these structures to (a) infill a focal chondral defect and mitigate macroscopic and cellular level changes in the cartilage surrounding the defect, and (b) support the development of a stratified multi-tissue scaffold for osteochondral tissue engineering.


Subject(s)
Biomimetics , Tissue Engineering , Cartilage , Chondrogenesis , Hydrogels , Printing, Three-Dimensional , Stereolithography , Tissue Scaffolds
4.
Orthop Rev (Pavia) ; 12(2): 8448, 2020 Aug 06.
Article in English | MEDLINE | ID: mdl-32922696

ABSTRACT

Due to the complex and dynamic nature of osteoarthritis (OA) and post-traumatic osteoarthritis (PTOA), animal models have been used to investigate the progression and pathogenesis of the disease. Researchers have used different experimental models to study OA and PTOA. With an emphasis on the knee joint, this review will compare and contrast the existing body of knowledge from anterior cruciate ligament transection models, meniscectomy models, combination models, as well as impact models in large animals to see how tissues respond to these different approaches to induce experimental OA and PTOA. The tissues discussed will include articular cartilage and the meniscus, with a focus on morphological, mechanical and histological assessments. The goal of this review is to demonstrate the progressive nature of OA by indicating the strong correlation between progressive tissue degeneration, change of mechanical properties, and loss of biochemical integrity and to highlight key differences between the most commonly used experimental animal models.

5.
Biochem Biophys Res Commun ; 514(3): 940-945, 2019 06 30.
Article in English | MEDLINE | ID: mdl-31088681

ABSTRACT

Focal defects in articular cartilage are unable to self-repair and, if left untreated, are a leading risk factor for osteoarthritis. This study examined cartilage degeneration surrounding a defect and then assessed whether infilling the defect prevents degeneration. We created a focal chondral defect in porcine osteochondral explants and cultured them ex vivo with and without dynamic compressive loading to decouple the role of loading. When compared to a defect in a porcine knee four weeks post-injury, this model captured loss in sulfated glycosaminoglycans (sGAGs) along the defect's edge that was observed in vivo, but this loss was not load dependent. Loading, however, reduced the indentation modulus of the surrounding cartilage. After infilling with in situ polymerized hydrogels that were soft (100 kPa) or stiff (1 MPa) and which produced swelling pressures of 13 and 310 kPa, respectively, sGAG loss was reduced. This reduction correlated with increased hydrogel stiffness and swelling pressure, but was not affected by loading. This ex vivo model recapitulates sGAG loss surrounding a defect and, when infilled with a mechanically supportive hydrogel, degeneration is minimized.


Subject(s)
Cartilage Diseases/pathology , Cartilage, Articular/pathology , Animals , Biomechanical Phenomena , Cartilage Diseases/therapy , Disease Models, Animal , Female , Hydrogels/therapeutic use , Proteoglycans/analysis , Swine
6.
Ann Biomed Eng ; 46(11): 1785-1796, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29922953

ABSTRACT

Pressure distribution of the native ovine knee meniscus was compared to a medial meniscectomy and three treatment conditions including a suture reattachment of the native tissue, an allograft, and a novel thermoplastic elastomer hydrogel (TPE) construct. The objective of this study was to assess the efficacy of a novel TPE hydrogel construct at restoring joint pressure and distribution. Limbs were loaded in uniaxial compression at 45°, 60°, and 75° flexion and from 0 to 181 kg. The medial meniscectomy decreased contact area by approximately 50% and doubled the mean and maximum pressure reading for the medial hemijoint. No treatment condition tested within this study was able to fully restore medial joint contact area and pressures to the native condition. A decrease in lateral contact area and increase in pressures with the meniscectomy was also seen; and to some degree, all reattachment and replacement conditions including the novel TPE hydrogel replacement helped to restore lateral pressures. Although the TPE construct did not perform as well as hoped in the medial compartment, it performed as well as, if not better, than the other reattachment and replacement options in the lateral. Further work is necessary to determine the best anchoring and attachment methods.


Subject(s)
Elastomers , Hydrogels , Knee Joint/physiopathology , Meniscus/physiopathology , Prostheses and Implants , Animals , Female , Knee Joint/pathology , Meniscectomy , Meniscus/pathology , Sheep , Weight-Bearing
7.
Prosthet Orthot Int ; 42(5): 511-517, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29623811

ABSTRACT

BACKGROUND: Designed by Dr. Sethi, the Jaipur Foot prosthesis is ideally suited for amputees in developing countries as it utilizes locally sourced, biodegradable, inexpensive materials and is focused on affordability and functionality. To date, however, no data have been reported on the material properties of the foot components. OBJECTIVES: The goal of this work was to evaluate mechanical properties of the Jaipur Foot components to guide foot design and manufacturing and reduce weight. STUDY DESIGN: Experimental. METHODS: Mechanical testing was conducted on two types of woods (ardu and cheed), microcellular rubber, tire cord, cushion compound, tread compound, and skin-colored rubber. Each material was subjected to testing in either tension or compression based on its location and function in the foot. Samples were tested before and after vulcanization. Two-sample t-tests were used to assess statistical differences. RESULTS: Cheed compressed perpendicular to the grain had a significantly higher modulus of elasticity than ardu ( p < 0.05); however, cheed had a higher density. Vulcanization significantly increased the modulus of skin-colored rubber, cushion compound, and tread compound ( p < 0.05) and decreased the moduli of both microcellular rubber and tire cord ( p < 0.05). CONCLUSION: The material property results from this study provide information for computer modeling to assess material construction on overall foot mechanics for design optimization. Ardu wood was ideal based on the desire to reduce weight, and the tire cord properties serve well to hold the foot together. Clinical relevance With new knowledge on the material properties of the components of the Jaipur Foot, future design modifications and standardized fabrication can be realized, making the Jaipur Foot more available on a global scale.


Subject(s)
Artificial Limbs , Compressive Strength , Foot , Materials Testing , Tensile Strength , Elastic Modulus , Humans , Prosthesis Design , Prosthesis Failure , Weight-Bearing
8.
J Mech Behav Biomed Mater ; 79: 341-347, 2018 03.
Article in English | MEDLINE | ID: mdl-29425534

ABSTRACT

Hydrogels are a class of synthetic biomaterials composed of a polymer network that swells with water and as such they have both an elastic and viscous component making them ideal for soft tissue applications. This study characterizes the compressive, tensile, and shear properties of a thermoplastic elastomer (TPE) hydrogel and compares the results to published literature values for soft tissues such as articular cartilage, the knee meniscus, and intervertebral disc components. The results show the TPE hydrogel material is viscoelastic, strain rate dependent, has similar surface and bulk properties, displays minimal damping under dynamic load, and has tension-compression asymmetry. When compared to other soft tissues it has a comparable equilibrium compressive modulus of approximately 0.5MPa and shear modulus of 0.2MPa. With a tensile modulus of only 0.2MPa though, the TPE hydrogel is inferior in tension to most collagen based soft tissues. Additional steps may be necessary to reinforce the hydrogel system and increase tensile modulus depending on the desired soft tissue application. It can be concluded that this material could be a viable option for soft tissue replacements.


Subject(s)
Biocompatible Materials , Elastomers , Hydrogels , Biomechanical Phenomena , Cartilage, Articular , Compressive Strength , Intervertebral Disc , Meniscus , Shear Strength , Stress, Mechanical
10.
Disabil Rehabil Assist Technol ; 13(8): 740-744, 2018 11.
Article in English | MEDLINE | ID: mdl-28844167

ABSTRACT

OBJECTIVE: The purpose of this study was to examine effects of usage and demographics on damage to the Jaipur Foot prosthesis as well as the epidemiology and etiology of amputations performed at Santokba Durlabjhi Memorial Hospital (SDMH) in Jaipur, India. DESIGN: Total time spent standing, total time spent wearing and total distance walked were compared against severity and location of damage to the prosthesis. Time between initial fitting and follow-up visit for damaged prosthetic was also considered in this analysis. A novel damage severity scale based on prosthesis functionality is presented along with a damage location legend. RESULTS: Patients from 10 different states and two territories throughout India were included in the study. No main effects were found to be statistically significant in predicting severity or location of damage. Only the interaction between a patient's total time spent standing and their total time spent wearing the prosthesis as well as the interaction between a patient's total time spent standing and total distance walked was significant in predicting location of damage to the Jaipur Foot (p = .0327, p = .0278, respectively). CONCLUSIONS: The lack of significant usage factor effect on damage severity or location could support previous findings that lack standardization in materials and manufacturing processes, which is the major drawback of the Jaipur Foot. Implications for Rehabilitation The Jaipur Foot is a safe, reliable and stable product as no abrupt breakage or sudden falls causing injury to the patient were noted. Hence, it is a safe rehabilitation device for lost limbs. The population can squat and sit cross-legged while wearing the prosthetic foot and it does not affect damage severity or location of damage, allowing for these activities to be performed while rehabilitating. The manufacturing of the foot needs to be standardized to improve life of foot. Total time spent standing, total time spent wearing and total distance walked were not predictive of severity or location of damage to the prosthesis, hence providing patient guidelines for activity during rehabilitation.


Subject(s)
Amputees/rehabilitation , Artificial Limbs/standards , Prosthesis Design/standards , Prosthesis Failure , Female , Foot , Humans , India , Male , Residence Characteristics , Socioeconomic Factors , Time Factors , Walking
11.
ACS Biomater Sci Eng ; 4(11): 3854-3863, 2018 Nov 12.
Article in English | MEDLINE | ID: mdl-33429608

ABSTRACT

Synthesis of hydrogel networks capable of accurately replicating the biomechanical demands of musculoskeletal soft tissues continues to present a formidable materials science challenge. Current systems are hampered by combinations of limited moduli at biomechanically relevant strains, inefficiencies driven by undesirable hysteresis and permanent fatigue, and recovery dynamics too slow to accommodate rapid cycling prominent in most biomechanical loading profiles. Here, we report on a novel paradigm in hydrogel design based on prefabrication of an efficient nanoscale network architecture using the melt-state self-assembly of amphiphilic block copolymers. Rigorous characterization and mechanical testing reveal that swelling of these preformed networks produces hydrogels with physiologically relevant moduli and water compositions, negligible hysteresis, subsecond elastic recovery rates, and unprecedented resistance to fatigue over hundreds of thousands of compression cycles. Furthermore, by relying only on simple thermoplastic processing to form these nanostructured networks, the synthetic complexities common to most solution-based hydrogel fabrication strategies are completely avoided.

13.
J Biomed Mater Res A ; 105(10): 2722-2728, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28556414

ABSTRACT

Understanding how human meniscal tissue responds to loading regimes mimetic of daily life as well as how it compares to larger animal models is critical in the development of a functionally accurate synthetic surrogate. Seven human and eight ovine cadaveric meniscal specimens were regionally sectioned into cylinders 5 mm in diameter and 3 mm thick along with 10 polystyrene-b-polyethylene oxide block copolymer-based thermoplastic elastomer (TPE) hydrogels. Samples were compressed to 12% strain at 1 Hz for 5000 cycles, unloaded for 24 h, and then retested. No differences were found within each group between test one and test two. Human and ovine tissue exhibited no regional dependency (p < 0.05). Human samples relaxed quicker than ovine tissue or the TPE hydrogel with modulus values at cycle 50 not significantly different from cycle 5000. Ovine menisci were found to be similar to human menisci in relaxation profile but had significantly higher modulus values (3.44 MPa instantaneous and 0.61 MPa after 5000 cycles compared with 1.97 and 0.11 MPa found for human tissue) and significantly different power law fit coefficients. The TPE hydrogel had an initial modulus of 0.58 MPa and experienced less than a 20% total relaxation over the 5000. Significant differences in the magnitude of compressive modulus between human and ovine menisci were observed, however the relaxation profiles were similar. Although statistically different than the native tissues, modulus values of the TPE hydrogel material were similar to those of the human and ovine menisci, making it a material worth further investigation for use as a synthetic replacement. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2722-2728, 2017.


Subject(s)
Biocompatible Materials/chemistry , Elastomers/chemistry , Hydrogel, Polyethylene Glycol Dimethacrylate/chemistry , Meniscus/chemistry , Polyethylene Glycols/chemistry , Polystyrenes/chemistry , Animals , Biomechanical Phenomena , Compressive Strength , Humans , Materials Testing , Sheep , Temperature
14.
J Orthop Res ; 35(3): 486-495, 2017 03.
Article in English | MEDLINE | ID: mdl-27129040

ABSTRACT

The objective of this study was to compare longitudinal results from two models of combined anterior cruciate ligament (ACL) and meniscal injury. A modified ACL transection (mACLT) model and a traumatic impact (ACLF) model were used to create an ACL rupture and acute meniscal damage in a Flemish Giant animal model. The animals were euthanized at time points of 4, 8, or 12 weeks. The menisci were assessed for equilibrium and instantaneous compressive modulus, as well as glycosaminoglycan (GAG) coverage. The articular cartilage was mechanically assessed for thickness, matrix modulus, fiber modulus, and permeability. Articular cartilage GAG coverage, fissuring, tidemark integrity, and subchondral bone thickness were measured. Both models resulted in damage indicative of osteoarthritis, including decreased meniscal mechanics and GAG coverage, increased permeability and fissuring of articular cartilage, and decreased GAG coverage. The mACLT model had an early and lasting effect on the menisci mechanics and GAG coverage, while cartilage damage was not significantly affected until 12 weeks. The ACLF model resulted in an earlier change of articular cartilage GAG coverage and fissuring in both the 8 and 12 week groups. The menisci were only significantly affected at the 12 week time point in the ACLF model. We concluded the progression of post traumatic osteoarthritis was dependent on injury modality: a point to be considered in future investigations. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:486-495, 2017.


Subject(s)
Anterior Cruciate Ligament Injuries/complications , Cartilage, Articular/pathology , Disease Models, Animal , Osteoarthritis, Knee/etiology , Tibial Meniscus Injuries/complications , Animals , Anterior Cruciate Ligament Injuries/pathology , Female , Male , Osteoarthritis, Knee/pathology , Rabbits , Tibial Meniscus Injuries/pathology
15.
J Mech Behav Biomed Mater ; 47: 57-64, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25846264

ABSTRACT

Traumatic injury to the knee leads to the development of post-traumatic osteoarthritis. The objective of this study was to characterize the effects of a single intra-articular injection of a non-ionic surfactant, Poloxamer 188 (P188), in preservation of meniscal tissue following trauma through maintenance of meniscal glycosaminoglycan (GAG) content and mechanical properties. Flemish Giant rabbits were subjected to a closed knee joint, traumatic compressive impact with the joint constrained to prevent anterior tibial translation. The contralateral limb served as an un-impacted control. Six animals (treated) received an injection of P188 in phosphate buffered saline (PBS) post trauma, and another six animals (sham) received a single injection of PBS to the impacted limb. Histological analyses for GAG was determined 6 weeks post trauma, and functional outcomes were assessed using stress relaxation micro-indentation. The impacted limbs of the sham group demonstrated a significant decrease in meniscal GAG coverage compared to non-impacted limbs (p<0.05). GAG coverage of the impacted P188 treated limbs was not significantly different than contralateral non-impacted limbs in all regions except the medial anterior (p<0.05). No significant changes were documented in mechanics for either the sham or treated groups compared to their respective control limbs. This suggests that a single intra-articular injection of P188 shows promise in prevention of trauma induced GAG loss.


Subject(s)
Menisci, Tibial/drug effects , Poloxamer/pharmacology , Surface-Active Agents/pharmacology , Tibial Meniscus Injuries , Wounds, Nonpenetrating/metabolism , Wounds, Nonpenetrating/pathology , Animals , Biomechanical Phenomena/drug effects , Femur/drug effects , Femur/injuries , Glycosaminoglycans/metabolism , Injections , Menisci, Tibial/metabolism , Menisci, Tibial/pathology , Poloxamer/administration & dosage , Rabbits , Surface-Active Agents/administration & dosage
16.
J Biomech ; 48(8): 1407-11, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-25770751

ABSTRACT

Healthy menisci function within the joint to prevent the underlying articular cartilage from excessive loads. Understanding how mechanical properties of menisci change with degeneration can drive future therapeutic studies to prevent this degeneration. Thus, the goal of this study was to characterize both compressive and tensile moduli of human menisci with varying degrees of gross damage due to osteoarthritis (OA). Twenty four paired menisci were collected from total knee joint replacement patients and the menisci were graded on a scale from 0-4 according to level of gross meniscal degeneration with 0=normal and 4=full tissue maceration. Each meniscus was then sectioned into anterior and posterior regions and subjected to indentation relaxation tests. Samples were sliced into 1mm thick strips, made into dumbbells using a custom punch, and pulled to failure. Significant decreases in instantaneous compressive modulus were seen in the lateral posterior region between grades 0 and 1 (36% decrease) and in the medial anterior regions between grades 1 and 2 (67% decrease) and 1 and 3 (72% decrease). Changes in equilibrium modulus where seen in the lateral anterior region between grades 1 and 2 (35% decrease), lateral posterior region between grades 0-2 (41% decrease), and medial anterior regions between grades 1 and 2 (59% decrease), 1 and 3 (67% decrease), 2 and 4 (54% decrease), and 3 and 4 (42% decrease). No significant changes were observed in tensile modulus across all regions and degenerative grades. The results of this study demonstrate the compressive moduli are affected even in early stages of gross degeneration, and continue to decrease with increased deterioration. However, osteoarthritic menisci retain a tensile modulus similar to that of previously reported healthy menisci. This study highlights progressive changes in meniscal mechanical compressive integrity as level of gross tissue degradation increases, and thus, early interventions should focus on restoring or preserving compressive integrity.


Subject(s)
Cartilage, Articular/physiopathology , Menisci, Tibial/physiopathology , Biomechanical Phenomena , Cartilage, Articular/pathology , Elastic Modulus , Female , Humans , Male , Menisci, Tibial/pathology , Middle Aged , Osteoarthritis/pathology , Osteoarthritis/physiopathology
17.
J Biomech ; 48(8): 1454-60, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-25776872

ABSTRACT

Inverse finite element (FE) analysis is an effective method to predict material behavior, evaluate mechanical properties, and study differences in biological tissue function. The meniscus plays a key role in load distribution within the knee joint and meniscal degradation is commonly associated with the onset of osteoarthritis. In the current study, a novel transversely isotropic hyper-poro-viscoelastic constitutive formulation was incorporated in a FE model to evaluate changes in meniscal material properties following tibiofemoral joint impact. A non-linear optimization scheme was used to fit the model output to indentation relaxation experimental data. This study is the first to investigate rate of relaxation in healthy versus impacted menisci. Stiffness was found to be decreased (p=0.003), while the rate of tissue relaxation increased (p=0.010) at twelve weeks post impact. Total amount of relaxation, however, did not change in the impacted tissue (p=0.513).


Subject(s)
Menisci, Tibial/pathology , Models, Biological , Osteoarthritis, Knee/pathology , Animals , Elasticity , Finite Element Analysis , Humans , Rabbits , Stress, Mechanical , Viscosity
18.
J Biomech ; 48(2): 246-53, 2015 Jan 21.
Article in English | MEDLINE | ID: mdl-25523754

ABSTRACT

The objective of this study was to induce anterior cruciate ligament (ACL) and meniscal damage, via a single tibiofemoral compressive impact, in order to document articular cartilage and meniscal changes post-impact. Tibiofemoral joints of Flemish Giant rabbits were subjected to a single blunt impact that ruptured the ACL and produced acute meniscal damage. Animals were allowed unrestricted cage activity for 12 weeks before euthanasia. India ink analysis of the articular cartilage revealed higher degrees of surface damage on the impacted tibias (p=0.018) and femurs (p<0.0001) compared to controls. Chronic meniscal damage was most prevalent in the medial central and medial posterior regions. Mechanical tests revealed an overall 19.4% increase in tibial plateau cartilage thickness (p=0.026), 34.8% increase in tibial plateau permeability (p=0.054), 40.8% increase in femoral condyle permeability (p=0.029), and 20.1% decrease in femoral condyle matrix modulus (p=0.012) in impacted joints compared to controls. Both instantaneous and equilibrium moduli of the lateral and medial menisci were decreased compared to control (p<0.02). Histological analyses revealed significantly increased presence of fissures in the medial femur (p=0.036). In both meniscus and cartilage there was a significant decrease in GAG coverage for the impacted limbs. Based on these results it is clear that an unattended combined meniscal and ACL injury results in significant changes to the soft tissues in this experimental joint 12 weeks post-injury. Such changes are consistent with a clinical description of mid to late stage PTOA of the knee.


Subject(s)
Cartilage, Articular/pathology , Knee Injuries/pathology , Mechanical Phenomena , Menisci, Tibial/pathology , Animals , Anterior Cruciate Ligament/pathology , Anterior Cruciate Ligament Injuries , Biomechanical Phenomena , Cartilage, Articular/injuries , Compressive Strength , Femur/injuries , Femur/pathology , Rabbits , Rupture/pathology , Tibia/injuries , Tibia/pathology , Tibial Meniscus Injuries , Time Factors
19.
J Biomech Eng ; 136(7)2014 Jul.
Article in English | MEDLINE | ID: mdl-24749144

ABSTRACT

Post-traumatic osteoarthritis (PTOA) develops as a result of traumatic loading that causes tears of the soft tissues in the knee. A modified transection model, where the anterior cruciate ligament (ACL) and both menisci were transected, was used on skeletally mature Flemish Giant rabbits. Gross morphological assessments, elastic moduli, and glycosaminoglycan (GAG) coverage of the menisci were determined to quantify the amount of tissue damage 12 weeks post injury. This study is one of the first to monitor meniscal changes after inducing combined meniscal and ACL transections. A decrease in elastic moduli as well as a decrease in GAG coverage was seen.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament/metabolism , Mechanical Phenomena , Menisci, Tibial , Proteoglycans/metabolism , Animals , Biomechanical Phenomena , Elastic Modulus , Glycosaminoglycans/metabolism , Rabbits
SELECTION OF CITATIONS
SEARCH DETAIL
...