1.
Appl Opt ; 60(26): 7955-7962, 2021 Sep 10.
Article in English | MEDLINE | ID: mdl-34613055

ABSTRACT

A novel fast proximal scanning method, to the best of our knowledge, termed fiber-core-targeted scanning (FCTS), is proposed for illuminating individual fiber cores sequentially to remove the pixelation effect in fiber bundle (FB) imaging. FCTS is based on a galvanometer scanning system. Through a dynamic control of the scan trajectory and speed using the prior knowledge of fiber core positions, FCTS experimentally verifies a precise sequential delivery of laser pulses into fiber cores at a maximal speed of 45,000 cores per second. By applying FCTS on a FB-based photoacoustic forward-imaging probe, the results demonstrate that FCTS eliminates the pixelation effect and improves the imaging quality.

2.
Biomed Opt Express ; 11(4): 2137-2151, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32341872

ABSTRACT

We present a dual modality functional optical coherence tomography and photoacoustic microscopy (OCT-PAM) system. The photoacoustic modality employs an akinetic optical sensor with a large imaging window. This imaging window enables direct reflection mode operation, and a seamless integration of optical coherence tomography (OCT) as a second imaging modality. Functional extensions to the OCT-PAM system include Doppler OCT (DOCT) and spectroscopic PAM (sPAM). This functional and non-invasive imaging system is applied to image zebrafish larvae, demonstrating its capability to extract both morphological and hemodynamic parameters in vivo in small animals, which are essential and critical in preclinical imaging for physiological, pathophysiological and drug response studies.

3.
Opt Lett ; 43(18): 4345, 2018 Sep 15.
Article in English | MEDLINE | ID: mdl-30211860

ABSTRACT

This publisher's note corrects an error in the funding section in Opt. Lett.42, 4319 (2017)OPLEDP0146-959210.1364/OL.42.004319.

4.
Opt Lett ; 42(21): 4319-4322, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-29088153

ABSTRACT

This Letter presents a novel dual modality reflection mode optical coherence and photoacoustic microscopy (OC-PAM) system. The optical coherence microscopy modality features a broadband source to accomplish 5 µm axial resolution. The photoacoustic microscopy modality uses a rigid akinetic Fabry-Perot etalon encapsulated in an optically transparent medium, which forms a 2 mm×11 mm translucent imaging window, permitting reflection mode dual modality imaging. After characterization, the OC-PAM system was applied to image zebrafish larvae in vivo, demonstrating its capability in biomedical imaging with complementary optical scattering and absorption contrasts by revealing morphology in the fish larvae.


Subject(s)
Microscopy/methods , Photoacoustic Techniques/methods , Animals , Fishes , Larva , Optics and Photonics , Spectrum Analysis
5.
Biomed Opt Express ; 7(10): 4171-4186, 2016 Oct 01.
Article in English | MEDLINE | ID: mdl-27867723

ABSTRACT

A novel all-optical akinetic ultrasound sensor, consisting of a rigid, fiber-coupled Fabry-Pérot etalon with a transparent central opening is presented. The sensing principle relies exclusively on the detection of pressure-induced changes of the refractive index in the fluid filling the Fabry-Pérot cavity. This enables resonance-free, inherently linear signal detection over a broad bandwidth. We demonstrate that the sensor achieves a exceptionally low peak noise equivalent pressure (NEP) values of 2 Pa over a 20 MHz measurement bandwidth (without signal averaging), while maintaining a flat frequency response, and a detection bandwidth up to 22.5 MHz (-6 dB). The measured large full field of view of the sensor is 2.7 mm × 1.3 mm and the dynamic range is [Formula: see text] or 63 dB at 20 MHz bandwidth. For different required amplitude ranges the upper amplitude detection limit can be customized from at least 2 kPa to 2 MPa by using cavity mirrors with a lower optical reflectivity. Imaging tests on a resolution target and on biological tissue show the excellent suitability of the akinetic sensor for optical resolution photoacoustic microscopy (OR-PAM) applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...