Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
J Cardiovasc Electrophysiol ; 34(12): 2493-2503, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37870157

ABSTRACT

INTRODUCTION: The prospective, nonrandomized, multicenter Q-FFICIENCY study demonstrated the safety and 12-month efficacy of paroxysmal atrial fibrillation (AF) ablation with the novel QDOT MICRO temperature-controlled, contact force-sensing, radiofrequency (RF) catheter. Participants underwent pulmonary vein isolation with very high-power short-duration (vHPSD) mode (90 W, ≤4 s) alone or combined with conventional-power temperature-controlled (CPTC) mode (25-50 W). This study aimed to assess quality-of-life (QOL) and healthcare utilization (HCU) benefits experienced by Q-FFICIENCY study participants. METHODS: Besides evaluating procedural efficiency, QOL and HCU were assessed through 12 months postablation via Atrial Fibrillation Effect on Quality-of-Life Tool (AFEQT) score, antiarrhythmic drug (AAD) use, and incidence of cardioversion and cardiovascular hospitalization. RESULTS: Of 191 participants enrolled, 166 were ablated with the new catheter. Compared to baseline, statistically significant, clinically meaningful improvements in composite and subcategories of AFEQT scores were observed at 3 months and sustained through 12 months (12-month increase, 29.3-44.2 points). Class I/III AAD use decreased from 97.6% (162/166) at baseline to 19.6% (31/158) during Months 6-12, representing a significant 79.9% reduction. The cardioversion rate significantly declined by 93.9% from 31.3% (12 months preablation) to 1.9% (evaluation period). One-year Kaplan-Meier estimates of freedom from all-cause and cardiovascular hospitalization were 80.9% (95% confidence interval [CI], 74.8%-86.9%) and 88.8% (95% CI, 84.0%-93.7%), respectively. CONCLUSIONS: Paroxysmal AF ablation with the novel temperature-controlled RF catheter in vHPSD mode, alone or with CPTC mode, led to clinically meaningful improvement in QOL and significant reduction in AAD use, cardioversion, and cardiovascular hospitalization.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Prospective Studies , Quality of Life , Temperature , Treatment Outcome , Catheters , Anti-Arrhythmia Agents/therapeutic use , Pulmonary Veins/surgery , Patient Acceptance of Health Care , Catheter Ablation/adverse effects
2.
JACC Clin Electrophysiol ; 9(4): 468-480, 2023 04.
Article in English | MEDLINE | ID: mdl-36752484

ABSTRACT

BACKGROUND: QDOT MICRO (QDM) is a novel contact force-sensing catheter optimized for temperature-controlled radiofrequency (RF) ablation. The very high-power short-duration (vHPSD) algorithm modulates power, maintaining target temperature during 90 W ablations for ≤4 seconds. OBJECTIVES: This study aims to evaluate safety and 12-month effectiveness of the QDM catheter in paroxysmal atrial fibrillation (AF) ablation using the vHPSD mode combined with conventional-power temperature-controlled (CPTC) mode. METHODS: In this prospective, multicenter, nonrandomized study, patients with drug-refractory, symptomatic paroxysmal AF underwent pulmonary vein (PV) isolation with QDM catheter with vHPSD as primary ablation mode, with optional use of the CPTC mode (25 to 50 W) for PV touch-up or non-PV ablation. The primary safety endpoint was incidence of primary adverse events within ≤7 days of ablation. The primary effectiveness endpoint was freedom from documented atrial tachyarrhythmia recurrence and acute procedural, repeat ablation, and antiarrhythmic drug failure. RESULTS: Of 191 enrolled participants, 166 had the catheter inserted, received RF ablation, and met eligibility criteria. Median procedural, RF application for ablating PVs, and fluoroscopy times were 132.0, 8.0, and 9.1 minutes, respectively. The primary adverse event rate was 3.6%. Imaging conducted in a subset of participants (n = 40) at 3 months did not show moderate or severe PV stenosis. The Kaplan-Meier estimated 12-month rate for primary effectiveness success was 76.7%; freedom from atrial tachyarrhythmia recurrence was 82.1%; clinical success (freedom from symptomatic recurrence) was 86.0%; and freedom from repeat ablation was 92.1%. CONCLUSIONS: Temperature-controlled paroxysmal AF ablation with the novel QDM catheter in vHPSD mode (90 W, ≤4 seconds), alone or with CPTC mode (25 to 50 W), is highly efficient and effective without compromising safety. (Evaluation of QDOT MICRO Catheter for Pulmonary Vein Isolation in Subjects With Paroxysmal Atrial Fibrillation [Q-FFICIENCY]; NCT03775512).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Radiofrequency Ablation , Humans , Temperature , Prospective Studies , Treatment Outcome , Catheter Ablation/methods
3.
J Interv Card Electrophysiol ; 61(1): 63-69, 2021 Jun.
Article in English | MEDLINE | ID: mdl-32462550

ABSTRACT

PURPOSE: The prospective, multicenter SMART SF trial demonstrated the acute safety and effectiveness of the 56-hole porous tip irrigated contact force (CF) catheter for drug-refractory paroxysmal atrial fibrillation (PAF) ablation with a low primary adverse event rate (2.5%), leading to FDA approval of the catheter. Here, we are reporting the long-term effectiveness and safety results that have not yet been reported. METHODS: Ablations were performed using the 56-hole porous tip irrigated CF catheter guided by the 3D mapping system stability module. The primary effectiveness endpoint was freedom from atrial tachyarrhythmia (including atrial fibrillation, atrial tachycardia, and/or atrial flutter), based on electrocardiographic data at 12 months. Atrial tachyarrhythmia recurrence occurring 3 months post procedure, acute procedural failures such as lack of entrance block confirmation of all PVs, and undergoing repeat procedure for atrial fibrillation in the evaluation period (91 to 365 days post the initial ablation procedure) were considered to be effectiveness failures. RESULTS: Seventy-eight patients (age 64.8 ± 9.7 years; male 52.6%; Caucasian 96.2%) participated in the 12-month effectiveness evaluation. Mean follow-up time was 373.5 ± 45.4 days. The Kaplan-Meier estimate of freedom from 12-month atrial tachyarrhythmia was 74.9%. Two procedure-related pericardial effusion events were reported at 92 and 180 days post procedure. There were no pulmonary vein stenosis complications or deaths reported through the 12-month follow-up period. CONCLUSIONS: The SMART SF 12-month follow-up evaluation corroborates the early safety and effectiveness success previously reported for PAF ablation with STSF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheters , Equipment Design , Humans , Male , Middle Aged , Porosity , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
4.
Europace ; 20(FI_3): f392-f400, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29016769

ABSTRACT

Aims: THERMOCOOL SMARTTOUCH® SF Catheter is a new contact-force (CF)-sensing catheter with 56-hole porous tip designed for improved cooling and reduced fluid delivery compared with a standard 6-hole open-irrigated catheter. The SMART SF study examined the periprocedural safety, acute effectiveness, and procedural efficiency of the catheter for drug-refractory symptomatic paroxysmal atrial fibrillation (PAF) ablation. Methods and results: The prospective, open-label, non-randomized SMART-SF was conducted at 17 US sites. Circumferential pulmonary vein (PV) isolation was performed with confirmation of entrance block in all PVs. Stable ablation sites were identified using CARTO VISITAG™ Module. Primary adverse events (AEs; ≤1 week of index procedure), periprocedural AEs within 30 days of ablation procedure, acute effectiveness (confirmation of entrance block for targeted PVs), CF, and procedural parameters were assessed. Overall, 165 patients were enrolled (mean age, 62.7 years; male, 57.9%; white, 97%; left ventricular ejection fraction, 60.1 ± 7%; left atrium diameter, 38.8 ± 6 mm); 159 underwent radiofrequency ablation and comprised the safety cohort. Primary safety performance criteria were met: primary AE rate was 2.5% (4/159; cardiac tamponade [n = 2], thrombo-embolism [n = 1], transient ischaemic attack [n = 1]). All primary AEs resolved/improved within the 1-month follow-up period. Acute procedural effectiveness was attained in 96.2% (95% confidence interval: 92.0-98.6%) of patients. Procedure time, fluoroscopy time, and fluid delivered were observed in comparison to predecessor catheters. Conclusion: In the SMART-SF trial, the predetermined safety performance goal was met, demonstrating the safety and acute effectiveness of the THERMOCOOL SMARTTOUCH® SF Catheter for PAF ablation.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheters , Catheter Ablation/instrumentation , Heart Rate , Pulmonary Veins/surgery , Therapeutic Irrigation/instrumentation , Action Potentials/drug effects , Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Drug Resistance , Equipment Design , Female , Heart Rate/drug effects , Humans , Male , Middle Aged , Porosity , Prospective Studies , Pulmonary Veins/physiopathology , Risk Factors , Therapeutic Irrigation/adverse effects , Time Factors , Treatment Outcome , United States
5.
Pacing Clin Electrophysiol ; 40(4): 391-400, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28151545

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) prevalence increases significantly with age. Little is known about the effect of AF ablation on quality of life and healthcare utilization in the elderly. The objective of this study was to quantify the healthcare utilization and quality of life benefits of catheter ablation for AF, for patients ≥65 years compared to patients <65 years. METHODS: Two multicenter U.S. registry studies enrolled patients with paroxysmal AF. Baseline characteristics and acute outcomes were collected for 736 patients receiving catheter ablation with the Navistar® ThermoCool® SF Catheter (Biosense Webster, Inc., Diamond Bar, CA, USA). Healthcare utilization and quality of life outcomes were collected through 1 year postablation for 508 patients. RESULTS: The rates of acute pulmonary vein isolation were high and similar between patients ≥65 years and <65 years (97.5% vs 95.8%, P = 0.2130). Length of stay for the index procedure was similar between age groups with 82.2% of the older group and 83.2% of the younger group having one-day hospitalization. Disease-specific quality of life instrument scores improved significantly and similarly for older and younger patients at 1 year postablation, compared to baseline. AF-related hospitalizations and emergency department visits were similar or lower in older patients compared to younger patients, as reported at 1 year postablation. CONCLUSION: For older patients undergoing catheter ablation for paroxysmal AF, healthcare utilization parameters were lower or not significantly different than for younger patients, and quality of life outcomes were similarly improved. These findings support the use of catheter ablation as a treatment option in older patients with paroxysmal AF.


Subject(s)
Atrial Fibrillation/psychology , Atrial Fibrillation/surgery , Catheter Ablation/psychology , Catheter Ablation/statistics & numerical data , Health Services Accessibility/statistics & numerical data , Quality of Life/psychology , Adult , Age Distribution , Aged , Aged, 80 and over , Atrial Fibrillation/epidemiology , Female , Humans , Male , Middle Aged , Prevalence , Retrospective Studies , Sex Distribution , Treatment Outcome , United States/epidemiology , Utilization Review , Young Adult
6.
J Cardiovasc Electrophysiol ; 25(8): 852-858, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24602038

ABSTRACT

INTRODUCTION: This report presents safety data on the use of a new open-irrigation radiofrequency ablation (RFA) catheter with a 56-hole porous tip in 742 patients enrolled in 2 US prospective, multicenter observational registry studies representing real-world use of the catheter. METHODS: This analysis is comprised of patients who underwent RFA of drug-refractory recurrent symptomatic paroxysmal atrial fibrillation (AF). Acute adverse events (AEs) were collected and categorized by seriousness, timing, and relatedness, with 7 days of follow-up data in one study and at least 120 days of data from a 1-year follow-up in the other. Acute serious adverse events (SAEs) that were identified as potentially related to the device and/or procedure were adjudicated by an independent safety committee. RESULTS: A total of 30 patients (4.0%) in the combined studies experienced an acute SAE related to the device and/or procedure, which was similar in the subset of patients age 65 and over (4.2%). These SAEs included 1.2% cardiac tamponade/perforation, 0.7% pericarditis, 0.5% pulmonary events, and 0.8% vascular access complications. No myocardial infarction, stroke, transient ischemic attack, or atrioesophageal fistulas within 7 days postprocedure were reported. In the study with extended follow-up, 1 pulmonary vein stenosis and 1 esophageal injury were seen beyond 7 days postprocedure (0.2% each). There were no device or procedure related deaths. CONCLUSION: Results from 2 large observational studies demonstrated that a new porous tip RFA catheter was safe for the treatment of drug refractory, recurrent, symptomatic paroxysmal AF, including treatment of older patients (≥65 years).


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheters , Catheter Ablation/instrumentation , Therapeutic Irrigation/instrumentation , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Equipment Design , Female , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Registries , Risk Factors , Therapeutic Irrigation/adverse effects , Time Factors , Treatment Outcome , United States
7.
J Invasive Cardiol ; 24(12): E308-10, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23220990

ABSTRACT

Despite over 6 decades of progress in the development of pharmacological therapy for hypertension, severe drug-resistant hypertension remains a major problem. Endovascular radiofrequency ablation of the proximal renal arteries has been reported to decrease renal artery sympathetic activity and improve long-term hypertensive control. Existing "approved" catheters for this procedure are solid tip, non-irrigated, and often difficult to steer. The existing technique uses angiography and lends itself to increased risk of renal scarring and possible stenosis. We describe a patient with multi-drug resistant hypertension who underwent catheter ablation of the bilateral renal arteries, using for the first time, an open irrigated cardiac ablation catheter with both electro-anatomical guidance and computerized tomography anatomical integration. We used "off-label" irrigated catheters, which are less prone to overheating and char formation at the catheter-surface interface, thereby decreasing the possibility of distal embolization to the renal parenchyma. The integration of electro-anatomical mapping into this procedure allowed us to avoid inadvertent circumferential ablation of the artery using electro-anatomical mapping may lower the risk of subsequent renal artery stenosis.


Subject(s)
Catheter Ablation/methods , Endovascular Procedures/methods , Hypertension/surgery , Renal Artery/innervation , Sympathectomy/methods , Aged , Antihypertensive Agents/therapeutic use , Drug Resistance , Humans , Hypertension/drug therapy , Male , Renal Artery Obstruction/epidemiology , Renal Artery Obstruction/prevention & control , Risk Factors , Treatment Outcome
8.
Congest Heart Fail ; 17(2): 51-5, 2011.
Article in English | MEDLINE | ID: mdl-21449992

ABSTRACT

The relative sensitivity and unexplained detection rate of changes in intrathoracic impedance has not been compared with standard heart failure (HF) monitoring using daily weight changes. The Fluid Accumulation Status Trial (FAST) prospectively followed 156 HF patients with implanted cardioverter-defibrillator or cardiac resynchronization therapy defibrillator devices modified to record daily changes in intrathoracic impedance in a blinded fashion for 537±312 days. Daily impedance changes were used to calculate a fluid index that could be compared with a prespecified threshold. True positives were defined as adjudicated episodes of worsening HF occurring within 30 days of a fluid index above threshold or an acute weight gain. Unexplained detections were defined as threshold crossings or acute weight gains not associated with worsening HF. Impedance measurements were performed on >99% of follow-up days, compared with only 76% of days for weight measurements. Sixty-five HF events occurred during follow-up (0.32/patient-year). Forty HF events were detected by impedance but not weight, whereas 5 were detected by weight but not impedance. Sensitivity was greater (76% vs 23%; P<.0001) and unexplained detection rate was lower (1.9 vs 4.3/patient-year; P<.0001) for intrathoracic impedance monitoring at the threshold of 60Ω days compared with acute weight increases of 3 lbs in 1 day or 5 lbs in 3 days and also over a wide range of fluid index and weight thresholds. The sensitivity and unexplained detection rate of intrathoracic impedance monitoring was superior to that seen for acute weight changes. Intrathoracic impedance monitoring represents a useful adjunctive clinical tool for managing HF in patients with implanted devices.


Subject(s)
Body Weight , Cardiography, Impedance/methods , Heart Failure/diagnosis , Aged , Body Fluids , Double-Blind Method , Female , Follow-Up Studies , Humans , Male , Prognosis , Prospective Studies
10.
Pacing Clin Electrophysiol ; 30(10): 1190-200, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17897121

ABSTRACT

BACKGROUND: The stimulation thresholds of left ventricular (LV) leads tend to be less reliable than conventional leads. Cardiac resynchronization therapy (CRT) requires continuous capture of both ventricles. OBJECTIVE: The purpose of this study is to evaluate a novel algorithm for the automatic measurement of the stimulation threshold of LV leads in cardiac resynchronization systems. METHODS: We enrolled 134 patients from 18 centers who had existing CRT-D systems. Software capable of automatically executing LV threshold measurements was downloaded into the random access memory (RAM) of the device. The threshold was measured by pacing in the left ventricle and analyzing the interventricular conduction sensed in the right ventricle. Automatic LV threshold measurements were collected and compared with manual LV threshold tests at each follow-up visit and using a Holter monitor system that recorded both the surface electrocardiograph (ECG) and continuous telemetry from the device. RESULTS: The proportion of Left Ventricular Capture Management (LVCM) in-office threshold tests within one programming step of the manual threshold test was 99.7% (306/307) with a two-sided 95% confidence interval of (98.2%, 100.0%). The algorithm measured the threshold successfully in 96% and 97% of patients after 1 and 3 months respectively. Holter monitor analysis in a subset of patients revealed accurate performance of the algorithm. CONCLUSION: This study demonstrated that the LVCM algorithm is safe, accurate, and highly reliable. LVCM worked with different types of leads and different lead locations. LVCM was demonstrated to be clinically equivalent to the manual LV threshold test. LVCM offers automatic measurement, output adaptation, and trends of the LV threshold and should result in improved ability to maintain LV capture without sacrificing device longevity.


Subject(s)
Cardiac Pacing, Artificial/methods , Ventricular Function , Aged , Algorithms , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable , Electrocardiography, Ambulatory , Female , Humans , Male , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...