1.
Appl Radiat Isot ; 209: 111326, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38701595

ABSTRACT

Thorium-227 was separated from its progeny and standardized for activity by the triple-to-double coincidence ratio (TDCR) method of liquid scintillation counting. Confirmatory liquid scintillation-based measurements were made using efficiency tracing with 3H and live-timed anticoincidence counting (LTAC). The separation time and the efficiency of the separation were confirmed by gamma-ray spectrometry. Calibrations for reentrant pressurized ionization chambers, including commercial radionuclide calibrators, and a well-type NaI(Tl) detector are discussed.

2.
Appl Radiat Isot ; 203: 111108, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38000166

ABSTRACT

Gadolinium-153 was standardized for activity by live-timed anticoincidence counting and an ampoule was submitted to the international reference system (SIR). Absolute emission intensities for the main γ rays were determined with calibrated high-purity germanium (HPGe) and lithium-drifted silicon (Si(Li)) detectors. A revised decay scheme is indicated, with no probability of direct electron capture to the 153Eu ground state. Triple-to-double coincidence ratio (TDCR) efficiency curves indicate that the revised decay scheme is consistent with experiment. Half-life measurements agree with a previous NIST determination and show no sensitivity to chemical environment.

3.
Appl Radiat Isot ; 201: 111025, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37717417

ABSTRACT

A manual microliter gravimetric dispensing technique is demonstrated using a micropipettor modified for use with removeable microcapillaries. Liquid scintillation sources were prepared from a well-characterized 241Am reference solution, providing a radiometric check of dispensed masses. Further experiments confirmed controlled dispensing of drops onto gold foils with losses ≤0.34(4) % of the total drop activity. A detailed measurement equation for the weighing technique, including the corrections for evaporation, is presented with a full accounting of associated uncertainties.

4.
Appl Radiat Isot ; 200: 110945, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37515859

ABSTRACT

The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study. The pilot study, involving 13 participating laboratories with primary calibration capabilities, validated the approach against the original international reference system based on ionization chambers, which has been in operation since 1976. The results are in agreement and an accuracy suitable for purpose, below 5×10-4, is achieved. The pilot study also reveals an issue when impurities emitting low-energy electrons are present in the standard solution, which have a different impact on liquid scintillation counting compared to other primary measurement methods.

5.
Appl Radiat Isot ; 190: 110473, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36201936

ABSTRACT

An activity standard for 212Pb in equilibrium with its progeny was realized, based on triple-to-double coincidence ratio (TDCR) liquid scintillation (LS) counting. A Monte Carlo-based approach to estimating uncertainties due to nuclear decay data (branching ratios, beta endpoint energies, γ-ray energies, and conversion coefficients for 212Pb and 208Tl) led to combined standard uncertainties ≤ 0.20 %. Confirmatory primary measurements were made by LS efficiency tracing with tritium and 4παß(LS)-γ(NaI(Tl)) anticoincidence counting. The standard is discussed in relation to current approaches to 212Pb activity calibration. In particular, potential biases encountered when using inappropriate radionuclide calibrator settings are discussed.


Subject(s)
Lead , Scintillation Counting , Scintillation Counting/methods , Radioisotopes , Tritium/analysis , Reference Standards
6.
J Res Natl Inst Stand Technol ; 126: 126048, 2021.
Article in English | MEDLINE | ID: mdl-38469443

ABSTRACT

We present a new paradigm for the primary standardization of radionuclide activity per mass of solution (Bq/g). Two key enabling capabilities are 4π decay-energy spectrometry using chip-scale sub-Kelvin microcalorimeters and direct realization of mass by gravimetric inkjet dispensing using an electrostatic force balance. In contrast to traditional traceability, which typically relies on chemical separation of single-radionuclide samples, 4π integral counting, and additional spectrometry methods to verify purity, the system described here has both 4π counting efficiency and spectroscopic resolution sufficient to identify multiple radionuclides in the same sample at once. This enables primary standardization of activity concentrations of mixed-radionuclide samples. A major benefit of this capability, beyond metrology, is in assay of environmental and forensics samples, for which the quantification of multiplenuclide samples can be achieved where presently inhibited by interferences. This can be achieved without the need for chemical separations or efficiency tracers, thereby vastly reducing time, radioactive waste, and resulting measurement uncertainty.

7.
Appl Radiat Isot ; 70(9): 2170-5, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22436452

ABSTRACT

In the triple-to-double coincidence ratio (TDCR) method of liquid scintillation counting, unaccounted or improperly accounted impurities can result in lower-than-expected or higher-than-expected recovered activities, depending on the counting efficiency of the nuclide of interest, the counting efficiency of the radionuclidic impurity, and the amount of impurity present. We describe these general dependences using a simple model. The trends predicted by the model are tested experimentally using a series of mixed (241)Am/(3)H and (63)Ni/(3)H sources. An "impurity surface" is derived to facilitate an intuitive grasp of impurity phenomena in TDCR.


Subject(s)
Artifacts , Complex Mixtures/analysis , Models, Chemical , Radioisotopes/analysis , Scintillation Counting/methods , Computer Simulation , Radiation Dosage