Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
BMC Oral Health ; 24(1): 387, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38532414

ABSTRACT

OBJECTIVE: Panoramic radiographs (PRs) provide a comprehensive view of the oral and maxillofacial region and are used routinely to assess dental and osseous pathologies. Artificial intelligence (AI) can be used to improve the diagnostic accuracy of PRs compared to bitewings and periapical radiographs. This study aimed to evaluate the advantages and challenges of using publicly available datasets in dental AI research, focusing on solving the novel task of predicting tooth segmentations, FDI numbers, and tooth diagnoses, simultaneously. MATERIALS AND METHODS: Datasets from the OdontoAI platform (tooth instance segmentations) and the DENTEX challenge (tooth bounding boxes with associated diagnoses) were combined to develop a two-stage AI model. The first stage implemented tooth instance segmentation with FDI numbering and extracted regions of interest around each tooth segmentation, whereafter the second stage implemented multi-label classification to detect dental caries, impacted teeth, and periapical lesions in PRs. The performance of the automated tooth segmentation algorithm was evaluated using a free-response receiver-operating-characteristics (FROC) curve and mean average precision (mAP) metrics. The diagnostic accuracy of detection and classification of dental pathology was evaluated with ROC curves and F1 and AUC metrics. RESULTS: The two-stage AI model achieved high accuracy in tooth segmentations with a FROC score of 0.988 and a mAP of 0.848. High accuracy was also achieved in the diagnostic classification of impacted teeth (F1 = 0.901, AUC = 0.996), whereas moderate accuracy was achieved in the diagnostic classification of deep caries (F1 = 0.683, AUC = 0.960), early caries (F1 = 0.662, AUC = 0.881), and periapical lesions (F1 = 0.603, AUC = 0.974). The model's performance correlated positively with the quality of annotations in the used public datasets. Selected samples from the DENTEX dataset revealed cases of missing (false-negative) and incorrect (false-positive) diagnoses, which negatively influenced the performance of the AI model. CONCLUSIONS: The use and pooling of public datasets in dental AI research can significantly accelerate the development of new AI models and enable fast exploration of novel tasks. However, standardized quality assurance is essential before using the datasets to ensure reliable outcomes and limit potential biases.


Subject(s)
Dental Caries , Tooth, Impacted , Tooth , Humans , Artificial Intelligence , Radiography, Panoramic , Bone and Bones
2.
J Dent ; 143: 104886, 2024 04.
Article in English | MEDLINE | ID: mdl-38342368

ABSTRACT

OBJECTIVE: Secondary caries lesions adjacent to restorations, a leading cause of restoration failure, require accurate diagnostic methods to ensure an optimal treatment outcome. Traditional diagnostic strategies rely on visual inspection complemented by radiographs. Recent advancements in artificial intelligence (AI), particularly deep learning, provide potential improvements in caries detection. This study aimed to develop a convolutional neural network (CNN)-based algorithm for detecting primary caries and secondary caries around restorations using bitewings. METHODS: Clinical data from 7 general dental practices in the Netherlands, comprising 425 bitewings of 383 patients, were utilized. The study used the Mask-RCNN architecture, for instance, segmentation, supported by the Swin Transformer backbone. After data augmentation, model training was performed through a ten-fold cross-validation. The diagnostic accuracy of the algorithm was evaluated by calculating the area under the Free-Response Receiver Operating Characteristics curve, sensitivity, precision, and F1 scores. RESULTS: The model achieved areas under FROC curves of 0.806 and 0.804, and F1-scores of 0.689 and 0.719 for primary and secondary caries detection, respectively. CONCLUSION: An accurate CNN-based automated system was developed to detect primary and secondary caries lesions on bitewings, highlighting a significant advancement in automated caries diagnostics. CLINICAL SIGNIFICANCE: An accurate algorithm that integrates the detection of both primary and secondary caries will permit the development of automated systems to aid clinicians in their daily clinical practice.


Subject(s)
Deep Learning , Dental Caries , Humans , Artificial Intelligence , Dental Caries Susceptibility , Neural Networks, Computer , ROC Curve , Dental Caries/therapy
3.
BMC Oral Health ; 23(1): 643, 2023 09 05.
Article in English | MEDLINE | ID: mdl-37670290

ABSTRACT

OBJECTIVE: Intra-oral scans and gypsum cast scans (OS) are widely used in orthodontics, prosthetics, implantology, and orthognathic surgery to plan patient-specific treatments, which require teeth segmentations with high accuracy and resolution. Manual teeth segmentation, the gold standard up until now, is time-consuming, tedious, and observer-dependent. This study aims to develop an automated teeth segmentation and labeling system using deep learning. MATERIAL AND METHODS: As a reference, 1750 OS were manually segmented and labeled. A deep-learning approach based on PointCNN and 3D U-net in combination with a rule-based heuristic algorithm and a combinatorial search algorithm was trained and validated on 1400 OS. Subsequently, the trained algorithm was applied to a test set consisting of 350 OS. The intersection over union (IoU), as a measure of accuracy, was calculated to quantify the degree of similarity between the annotated ground truth and the model predictions. RESULTS: The model achieved accurate teeth segmentations with a mean IoU score of 0.915. The FDI labels of the teeth were predicted with a mean accuracy of 0.894. The optical inspection showed excellent position agreements between the automatically and manually segmented teeth components. Minor flaws were mostly seen at the edges. CONCLUSION: The proposed method forms a promising foundation for time-effective and observer-independent teeth segmentation and labeling on intra-oral scans. CLINICAL SIGNIFICANCE: Deep learning may assist clinicians in virtual treatment planning in orthodontics, prosthetics, implantology, and orthognathic surgery. The impact of using such models in clinical practice should be explored.


Subject(s)
Deep Learning , Humans , Algorithms , Calcium Sulfate , Dental Care , Physical Examination
4.
Int J Implant Dent ; 9(1): 27, 2023 09 07.
Article in English | MEDLINE | ID: mdl-37676412

ABSTRACT

PURPOSE: To investigate the influence of teeth and dental restorations on the facial skeleton's gray value distributions in cone-beam computed tomography (CBCT). METHODS: Gray value selection for the upper and lower jaw segmentation was performed in 40 patients. In total, CBCT data of 20 maxillae and 20 mandibles, ten partial edentulous and ten fully edentulous in each jaw, respectively, were evaluated using two different gray value selection procedures: manual lower threshold selection and automated lower threshold selection. Two sample t tests, linear regression models, linear mixed models, and Pearson's correlation coefficients were computed to evaluate the influence of teeth, dental restorations, and threshold selection procedures on gray value distributions. RESULTS: Manual threshold selection resulted in significantly different gray values in the fully and partially edentulous mandible. (p = 0.015, difference 123). In automated threshold selection, only tendencies to different gray values in fully edentulous compared to partially edentulous jaws were observed (difference: 58-75). Significantly different gray values were evaluated for threshold selection approaches, independent of the dental situation of the analyzed jaw. No significant correlation between the number of teeth and gray values was assessed, but a trend towards higher gray values in patients with more teeth was noted. CONCLUSIONS: Standard gray values derived from CT imaging do not apply for threshold-based bone segmentation in CBCT. Teeth influence gray values and segmentation results. Inaccurate bone segmentation may result in ill-fitting surgical guides produced on CBCT data and misinterpreting bone density, which is crucial for selecting surgical protocols. Created with BioRender.com.


Subject(s)
Mouth, Edentulous , Humans , Pilot Projects , Face , Computers , Cone-Beam Computed Tomography
5.
Clin Oral Implants Res ; 34(8): 793-801, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37314046

ABSTRACT

OBJECTIVES: Intraoral scans of multiple implants in the edentulous arch are challenged by the absence of a distinct surface morphology between scan bodies. A scan aid was applied in such situation and evaluated for intraoral scanning accuracy in vivo. MATERIALS AND METHODS: 87 implants in 22 patients were scanned with scan aid (SA) and without scan aid (NO) using two different intraoral scanners (CS3600 [CS] and TRIOS3 [TR]). Master casts were digitized by a laboratory scanner. Virtual models were superimposed using an inspection software and Linear deviation and precision were measured. Statistical analysis was performed using linear mixed models (α = .05). RESULTS: Total mean linear deviation within the CS group was 189 µm without scan aid and 135 µm when using the scan aid. The TR group's total mean deviation was 165 µm with and without a scan aid. Significant improvement with scan aid was observed for the CS group (p = .001), and no difference was found in the TR group. 96% of scan bodies were successfully scanned in the TR-SA group compared to 86% for the TR-NO group, 83% for the CS-SA, and 70% for the CS-NO group, respectively. CONCLUSIONS: The evaluated scan aid improved linear deviation compared to unsplinted scans for the CS group but not for the TR group. These differences could originate from different scanning technologies used, active triangulation (CS) and confocal microscopy (TR). The scan aid improved the ability to recognize scan bodies successfully with both systems, which could have a favorable clinical impact overall.


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Imaging, Three-Dimensional , Dental Impression Technique , Computer-Aided Design , Models, Dental , Mouth, Edentulous/diagnostic imaging , Mouth, Edentulous/surgery
6.
Dentomaxillofac Radiol ; 52(4): 20220333, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36988090

ABSTRACT

MRI is increasingly used as a diagnostic tool for visualising the dentoalveolar complex. A comprehensive review of the current indications and applications of MRI in the dental specialities of orthodontics (I), endodontics (II), prosthodontics (III), periodontics (IV), and oral surgery (V), pediatric dentistry (VI), operative dentistry is still missing and is therefore provided by the present work.The current literature on dental MRI shows that it is used for cephalometry in orthodontics and dentofacial orthopaedics, detection of dental pulp inflammation, characterisation of periapical and marginal periodontal pathologies of teeth, caries detection, and identification of the inferior alveolar nerve, impacted teeth and dentofacial anatomy for dental implant planning, respectively. Specific protocols regarding the miniature anatomy of the dentofacial complex, the presence of hard tissues, and foreign body restorations are used along with dedicated coils for the improved image quality of the facial skull.Dental MRI poses a clinically useful radiation-free imaging tool for visualising the dentoalveolar complex across dental specialities when respecting the indications and limitations.


Subject(s)
Endodontics , Orthodontics , Child , Humans , Standard of Care , Dentistry, Operative , Magnetic Resonance Imaging/methods
7.
Sci Rep ; 13(1): 2296, 2023 02 09.
Article in English | MEDLINE | ID: mdl-36759684

ABSTRACT

Oral squamous cell carcinoma (OSCC) is amongst the most common malignancies, with an estimated incidence of 377,000 and 177,000 deaths worldwide. The interval between the onset of symptoms and the start of adequate treatment is directly related to tumor stage and 5-year-survival rates of patients. Early detection is therefore crucial for efficient cancer therapy. This study aims to detect OSCC on clinical photographs (CP) automatically. 1406 CP(s) were manually annotated and labeled as a reference. A deep-learning approach based on Swin-Transformer was trained and validated on 1265 CP(s). Subsequently, the trained algorithm was applied to a test set consisting of 141 CP(s). The classification accuracy and the area-under-the-curve (AUC) were calculated. The proposed method achieved a classification accuracy of 0.986 and an AUC of 0.99 for classifying OSCC on clinical photographs. Deep learning-based assistance of clinicians may raise the rate of early detection of oral cancer and hence the survival rate and quality of life of patients.


Subject(s)
Carcinoma, Squamous Cell , Head and Neck Neoplasms , Mouth Neoplasms , Humans , Carcinoma, Squamous Cell/diagnosis , Carcinoma, Squamous Cell/pathology , Mouth Neoplasms/diagnosis , Mouth Neoplasms/pathology , Squamous Cell Carcinoma of Head and Neck , Quality of Life
8.
Sci Rep ; 12(1): 19596, 2022 11 15.
Article in English | MEDLINE | ID: mdl-36379971

ABSTRACT

Mandibular fractures are among the most frequent facial traumas in oral and maxillofacial surgery, accounting for 57% of cases. An accurate diagnosis and appropriate treatment plan are vital in achieving optimal re-establishment of occlusion, function and facial aesthetics. This study aims to detect mandibular fractures on panoramic radiographs (PR) automatically. 1624 PR with fractures were manually annotated and labelled as a reference. A deep learning approach based on Faster R-CNN and Swin-Transformer was trained and validated on 1640 PR with and without fractures. Subsequently, the trained algorithm was applied to a test set consisting of 149 PR with and 171 PR without fractures. The detection accuracy and the area-under-the-curve (AUC) were calculated. The proposed method achieved an F1 score of 0.947 and an AUC of 0.977. Deep learning-based assistance of clinicians may reduce the misdiagnosis and hence the severe complications.


Subject(s)
Deep Learning , Mandibular Fractures , Humans , Radiography, Panoramic/methods , Mandibular Fractures/diagnostic imaging , Algorithms , Area Under Curve
9.
Clin Oral Implants Res ; 33(10): 1010-1020, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35861128

ABSTRACT

OBJECTIVES: Optical impressions of implants in the edentulous arch are challenged by the absence of distinct surface morphology between multiple implant scan bodies. The purpose of this in vitro study was to evaluate a newly developed scan aid in various designs and colors to improve the accuracy of multi-implant scans. MATERIALS AND METHODS: A universal scan aid in three different designs (circular, square, irregular) and three different materials (colors: beige, gray, white) was applied to the implant scan bodies of a master model of six implants in an edentulous maxilla. Ten scans using an intra-oral scanner of each scan aid were acquired. Reference scanning was performed using a desktop optical scanner. Alignment of scans was performed at the first scan body in a three-dimensional modeling and inspection software and deviations for trueness and precision were calculated using the signed nearest-neighbor method and then statistically analyzed (α = .05). RESULTS: Overall, the beige irregular scan aid had the highest trueness and showed significant differences compared to unsplinted scans. The precision showed more heterogenous results and decreased when using the scan aid. Ease of use was observed with the irregular gray scan aid due to its increased elongation at break. CONCLUSIONS: The evaluated scan aid led to improved trueness when compared to unsplinted scans. Even though the irregular design in beige color showed highest trueness, the poor fracture strength of the tested material requires further improvement.


Subject(s)
Dental Implants , Mouth, Edentulous , Computer-Aided Design , Dental Impression Technique , Humans , Imaging, Three-Dimensional , Models, Dental
10.
Invest Radiol ; 57(11): 720-727, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-35640007

ABSTRACT

OBJECTIVES: The aims of this study were to quantify T1/T2-relaxation times of the dental pulp, develop a realistic tooth model, and compare image quality between cone-beam computed tomography (CBCT) and high-resolution magnetic resonance imaging (MRI) of single teeth using a wireless inductively coupled intraoral coil. METHODS: T1/T2-relaxometry was performed at 3 T in 10 healthy volunteers (283 teeth) to determine relaxation times of healthy dental pulp and develop a realistic tooth model using extracted human teeth. Eight MRI sequences (DESS, CISS, TrueFISP, FLASH, SPACE, TSE, MSVAT-SPACE, and UTE) were optimized for clinically applicable high-resolution imaging of the dental pulp. In model, image quality of all sequences was assessed quantitatively (contrast-to-noise ratio) and qualitatively (visibility of anatomical structures and extent of susceptibility artifacts using a 5-point scoring scale). Cone-beam computed tomography served as the reference modality for qualitative assessment. Statistical analysis was performed using 2-way analysis of variance, Fisher exact test, and Cohen κ. RESULTS: In vivo, relaxometry of dental pulps revealed T1/T2 relaxation times at 3 T of 738 ± 100/171 ± 36 milliseconds. For all sequences, an isotropic resolution of (0.21 mm) 3 was achieved, with acquisition times ranging from 6:19 to 8:02 minutes. In model, the highest contrast-to-noise ratio values were observed for UTE, followed by TSE and CISS. The best image/artifact quality, however, was found for DESS (mean ± SD: 1.3 ± 0.3/2.2 ± 0.0), FLASH (1.5 ± 0.3/2.4 ± 0.1), and CISS (1.5 ± 0.4/2.5 ± 0.1), at a level comparable to CBCT (1.2 ± 0.3/2.1 ± 0.1). CONCLUSIONS: Optimized MRI protocols using an intraoral coil at 3 T can achieve an image quality comparable to reference modality CBCT within clinically applicable acquisition times. Overall, DESS revealed the best results, followed by FLASH and CISS.


Subject(s)
Spiral Cone-Beam Computed Tomography , Artifacts , Cone-Beam Computed Tomography/methods , Humans , Magnetic Resonance Imaging/methods
11.
Front Surg ; 9: 778371, 2022.
Article in English | MEDLINE | ID: mdl-35372463

ABSTRACT

Background: This study was conducted to evaluate the feasibility, clinical outcomes, and accuracy of patient-specific 3D-printed miniplates for mandible reconstruction with fibula free flaps. Methods: A feasibility study was conducted with 8 patients. Following virtual planning, patient-specific 1.0 mm titanium non-locking miniplates were produced via laser selective melting. 3D-printed cutting and drilling guides were used for segmental mandible resection and flap harvesting. Flap fixation was performed with two 4-hole miniplates and 2.0 mm non-locking screws (screw length 7 mm) for each intersegmental gap. Clinical follow-up was at least 6 months. Preoperative and postoperative CT/cone beam CT data were used for 3D accuracy analysis and evaluation of bone healing. Plate-related complications were monitored clinically. Results: Patient-specific miniplate fixation of all flaps was successfully conducted (4 mono-segmental, 4 dual-segmental) with high accuracy (3.64 ± 1.18 mm) between the virtual plan and postoperative result. No technical complications were encountered intraoperatively. Osseous union occurred in all intersegmental gaps (1 partial, 18 complete) after 10 ± 2 months. No material fracture, dislocation, or plate exposure was observed. Conclusions: Based on this pilot observational study including a limited number of patients, free flap fixation for mandibular reconstruction with patient-specific 3D-printed miniplates is feasible and associated with high accuracy, bone healing, and remote soft tissue complications.

12.
BMC Oral Health ; 22(1): 23, 2022 01 30.
Article in English | MEDLINE | ID: mdl-35094677

ABSTRACT

BACKGROUND: Patient- and technology-related parameters influence the successful implementation of virtual implant planning and guided implant surgery. Besides data processing and computer aided design of drill guides as described in Part I, the possibilities and limitations for prosthetic set-up and virtual implant planning are essential (Part II). METHODS: The following software systems were examined using two different clinical situations for implant therapy: coDiagnostiX™, DentalWings, Canada (CDX); Simplant Pro™, Dentsply, Sweden (SIM); Smop™, Swissmeda, Switzerland (SMP); NobelClinician™, Nobel Biocare, Switzerland (NC); Implant Studio, 3Shape, Denmark (IST). Assessment criteria geared towards interfaces and integrated tools for prosthetic set-up and virtual implant planning. RESULTS: A software interface for an individual virtual prosthetic set-up was provided by two systems (CDX, IST), whereas the set-up of standardized teeth was provided by four systems (CDX, SIM, SMP, IST). Alternatively, a conventional set-up could be scanned and imported. One system could solely work with the digitization of a conventional set-up for virtual implant planning (NC). Stock abutments could be displayed for implant planning, but none of the tested software systems provided tools for the design of an individual abutment. All systems displayed three-dimensional reconstructions or two-dimensional cross-sections with varying orientation for virtual implant placement. The inferior alveolar nerve could be marked to respect a minimum distance between the nerve and the planned implant. Three implant planning systems provided a library to display more than 50 implant systems (CDX, SIM, IST), one system provided 33 implant systems (SMP) and one implant system provided 4 implant systems (NC). CONCLUSION: Depending on the used software system, there are limited options for a virtual set-up, virtual articulators and the display of a virtual prosthetic set-up. The implant systems used by the clinician is important for the decision which software system to choose, as there is a discrepancy between available implant systems and the number of supported systems in each software.


Subject(s)
Dental Implants , Surgery, Computer-Assisted , Computer-Aided Design , Dental Implantation, Endosseous/methods , Humans , Imaging, Three-Dimensional/methods , Patient Care Planning , Software , Surgery, Computer-Assisted/methods
13.
J Prosthet Dent ; 128(6): 1303-1309, 2022 Dec.
Article in English | MEDLINE | ID: mdl-33902891

ABSTRACT

STATEMENT OF PROBLEM: The accuracy of intraoral scanners is a prerequisite for the fabrication of dental restorations in computer-aided design and computer-aided manufacturing (CAD-CAM) dentistry. While the precision of intraoral scanners has been investigated in vitro, clinical data on the accuracy of intraoral scanning (IOS) are limited. PURPOSE: The purpose of this clinical study was to determine the accuracy of intraoral scanning with different devices compared with extraoral scanning. MATERIAL AND METHODS: An experimental appliance was fabricated for 11 participants and then scanned intraorally and extraorally with 3 different intraoral scanners and a reference scanner. Intraoral and extraoral scans were subdivided into complete-arch and short-span scans and compared with the reference scan to assess trueness. Repeated scans in each group were assessed for precision. RESULTS: Precision and trueness were higher for extraoral scans compared with intraoral scans, except for complete-arch scans with 1 intraoral scanner. The median precision of short-span scans was higher (extraoral: 22 to 29 µm, intraoral: 23 to 43 µm) compared with complete-arch scans (extraoral: 81 to 165 µm, intraoral: 80 to 198 µm). The median trueness of short-span scans (extraoral: 28 to 40 µm, intraoral: 38 to 47 µm) was higher than that of complete-arch scans (extraoral: 118 to 581 µm, intraoral: 147 to 433 µm) for intraoral and extraoral scanning. CONCLUSIONS: Intraoral conditions negatively influenced the accuracy of the scanning devices, which was also reduced for the complete-arch scans.


Subject(s)
Dental Impression Technique , Models, Dental , Humans , Imaging, Three-Dimensional , Computer-Aided Design , Dental Arch
14.
BMC Oral Health ; 21(1): 287, 2021 06 04.
Article in English | MEDLINE | ID: mdl-34088298

ABSTRACT

BACKGROUND: The anatomical features of the gingiva and the clinical crowns and their interrelation, especially in aesthetically and functionally demanding areas, are important in complex dental or implant-retained prosthetic rehabilitations. This observational cross-sectional study was designed to evaluate gender- and age-related differences in the width of attached gingiva (WAG), the clinical crown length (CCL), and their interrelation in the anterior teeth to determine the relationship between the pink and white aesthetics. METHODS: Eighty (54 females, 26 males) fully dentate Caucasian participants between the ages of 20 and 25 years and 36 probands (23 females, 13 males) between the ages of 45 and 55 years were included in the present study. The CCL of the maxillary and mandibular canines, as well as the central incisors of the maxilla and mandible, were determined with a dental sliding caliper measuring from the middle margin of the gingiva at its deepest point to the incisal edge. The clinical investigation of the WAG was performed by inserting a periodontal probe into the gingival sulcus in the middle of the buccal surface to firstly measure the probing pocket depth. The distance between the gingival margin and mucogingival junction (MGJ) was then measured with a Beerendonk sliding caliper in the middle of the labial curvature, and the clinical WAG was determined by subtraction of the measured probing depth. For the statistical analysis, the Mann-Whitney U test, the Wilcoxon-Test, the Spearman's rank correlation, and a two-factorial non-parametric analysis were used. RESULTS: There was no correlation between the CCL and the WAG in a healthy periodontium. Gender influenced the CCL, with men having significantly longer teeth than women in both maxilla (P ≤ 0.01) and mandible (P ≤ 0.05). Age did not influence the CCL significantly neither in the upper (P = 0.06) nor in the lower jaw (P = 0.33). Gender did not show to have a significant influence on the WAG of maxilla (P = 0.69) and mandible (P = 0.26). But differences in the WAG between young and old participants were observed in both upper (P ≤ 0.01) and lower jaw (P ≤ 0.05). CONCLUSION: The present observational study demonstrated that the mean values of cohorts with mixed age groups and genders should not be considered when attempting to determine the ideal relationships between the pink and white aesthetics since the statistical analyses showed significant differences between different age groups and genders.


Subject(s)
Gingiva , Incisor , Adult , Crowns , Esthetics, Dental , Female , Humans , Male , Maxilla , Odontometry , Young Adult
15.
Int J Prosthodont ; 34: s8-s20, 2021.
Article in English | MEDLINE | ID: mdl-33571323

ABSTRACT

The tasks of Working Groups 1 to 6 at the 4th Consensus Meeting of the Oral Reconstruction Foundation were to elucidate clinical recommendations for implant-supported full-arch rehabilitations in edentulous patients. Six systematic/narrative reviews were prepared to address the following subtopics: (1) the influence of medical and geriatric factors on implant survival; (2) the prevalence of peri-implant diseases; (3) the influence of material selection, attachment type, interarch space, and opposing dentition; (4) different interventions for rehabilitation of the edentulous maxilla; (5) different interventions for rehabilitation of the edentulous mandible; and (6) treatment choice and decision-making in elderly patients. Consensus statements, clinical recommendations, and implications for future research were determined based on structured group discussions and plenary session approval.


Subject(s)
Dental Implants , Jaw, Edentulous , Mouth, Edentulous , Aged , Consensus , Dental Prosthesis, Implant-Supported , Humans , Maxilla
16.
Dentomaxillofac Radiol ; 50(2): 20200068, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33201739

ABSTRACT

OBJECTIVES: Autologous bone grafts are the gold standard to augment deficient alveolar bone. Dimensional graft alterations during healing are not known as they are not accessible to radiography. Therefore, MRI was used to display autologous onlay bone grafts in vivo during early healing. METHODS AND MATERIALS: Ten patients with alveolar bone atrophy and autologous onlay grafts were included. MRI was performed with a clinical MR system and an intraoral coil preoperatively (t0), 1 week (t1), 6 weeks (t2) and 12 weeks (t3) postoperatively, respectively. The graft volumes were assessed in MRI by manual segmentation by three examiners. Graft volumes for each time point were calculated and dimensional alteration was documented. Cortical and cancellous proportions of bone grafts were assessed. The intraobserver and interobserver variability were calculated. Statistical analysis was performed using a mixed linear regression model. RESULTS: Autologous onlay bone grafts with cortical and cancellous properties were displayed in vivo in eight patients over 12 weeks. The fixation screws were visible as signal voids with a thin hyperintense fringe. The calculated volumes were between 0.12-0.74 cm3 (t1), 0.15-0.73 cm3 (t2), and 0.17-0.64 cm3 (t3). Median changes of bone graft volumes of -15% were observed. There was no significant difference between the examiners (p = 0.3). CONCLUSIONS: MRI is eligible for the display and longitudinal observation of autologous onlay bone grafts. Image artifacts caused measurements deviations in some cases and minimized the precise assessment of graft volume. To the knowledge of the authors, this is the first study that used MRI for the longitudinal observation of autologous onlay bone grafts.


Subject(s)
Alveolar Bone Loss , Alveolar Ridge Augmentation , Bone Transplantation , Bone and Bones , Humans , Magnetic Resonance Imaging , Wound Healing
17.
BMC Oral Health ; 20(1): 251, 2020 09 10.
Article in English | MEDLINE | ID: mdl-32912273

ABSTRACT

BACKGROUND: Virtual implant planning systems integrate (cone beam-) computed tomography data to assess bone quantity and virtual models for the design of the implant-retained prosthesis and drill guides. Five commercially available systems for virtual implant planning were examined regarding the modalities of integration of radiographic data, virtual dental models and the design of drill guides for guided implant surgery. The purpose of this review was to describe the limitations of these available systems regarding the import of imaging data and the design and fabrication of a drill guide. METHODS: The following software systems were examined regarding the import of imaging data and the export of the virtual implant planning for the design and fabrication of a drill guide with the help of two clinical situations requiring dental implant therapy: coDiagnostiX™, DentalWings, Canada (CDX); Simplant Pro™, Dentsply, Sweden (SIM); Smop™, Swissmeda, Switzerland (SMP); NobelClinician™, Nobel Biocare, Switzerland (NC); Implant Studio, 3Shape, Denmark (IST). Assessment criteria included data formats and management as well as the workflow for the design and production of drill guides. RESULTS: All systems have a DICOM-interface ("Digital Imaging and Communication in Medicine") for the import of radiographic data. Imaging artefacts could be reduced but not eliminated by manual data processing. The import of virtual dental models in a universal format (STL: Standard Tesselation Language) was possible with three systems; one system could only be used with a proprietary data format. All systems display three-dimensional surface models or two-dimensional cross-sections with varying orientation for virtual implant planning. Computer aided design and manufacturing (CAD/CAM) of drill guides may be performed by the user with the help of default parameters or solely by the provider of the software and thus without the influence of the clinician. CONCLUSION: Data bases of commonly used implant systems are available in all tested software, however not all systems allow to plan and execute fully guided implant placement. An individual design and in-house manufacturing of the drill guide is only available in some software systems. However, at the time of publication most recent software versions showed flexibility in individual design and in-house manufacturing of drill guides.


Subject(s)
Dental Implants , Surgery, Computer-Assisted , Canada , Computer-Aided Design , Cone-Beam Computed Tomography , Dental Implantation, Endosseous , Imaging, Three-Dimensional , Patient Care Planning , Software , Sweden , Switzerland
18.
Clin Oral Implants Res ; 31(11): 1149-1158, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32881075

ABSTRACT

AIMS: The aim of this prospective, clinical study was to evaluate the clinical performance and histological outcome of a new equine hydroxyapatite collagenated bone block (eHAC) for horizontal bone grafting prior to implant placement. MATERIALS AND METHODS: Five patients (two male/three female) with a mean age of 51.6 years (range 22-66 years) and a reduced horizontal bone width of the alveolar ridge (mean 3.5 mm) underwent horizontal bone grafting using eHAC at 10 grafting sites. Reentry was performed 6.9 months after the horizontal grafting procedure. Clinical follow-up (mean 28.9 month) considered width gain of the alveolar ridge, soft tissue healing, and complications. To evaluate graft incorporation, four additional patients underwent histological assessment of equine blocks adjacent to autologous blocks 3 and 6 months after grafting. RESULTS: The study was terminated after graft failure was observed in four of five patients. Mean horizontal bone width had increased by 3.6 ± 1.22 mm. Three out of nine implants placed had to be removed due to graft failure. Histological evaluation revealed large amounts of soft connective tissue within the grafts (mean 67.3 ± 9.5%). The proportion of new bone formation 3 months after the lateral grafting procedure revealed an average of 8.6%, compared to 11.4% after 6 to 7 months. CONCLUSION: Lateral ridge grafting using eHAC achieved measurable horizontal width gain but revealed high rates of severe complications. CLINICAL IMPLICATIONS: Within the limitations of this study, eHAC bone blocks cannot be recommended for horizontal bone grafting.


Subject(s)
Alveolar Ridge Augmentation , Bone Transplantation , Adult , Aged , Animals , Cancellous Bone , Dental Implantation, Endosseous , Female , Horses , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies , Treatment Outcome , Young Adult
19.
Clin Oral Implants Res ; 31(8): 737-746, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32459868

ABSTRACT

OBJECTIVES: The objective of this in vitro study was to assess the accuracy of fully guided implant placement following virtual implant planning based on MRI. MATERIAL AND METHODS: Sixteen human cadaver hemimandibles with single missing teeth (n = 3), partially edentulous (n = 6) and edentulous situations (n = 7) were imaged using MRI. MRI and optical scans obtained with an intraoral scanner, were imported into an implant planning software. Virtual prosthetic and implant planning were performed regarding hard- and soft-tissue anatomy. Drill guides were manufactured, and fully guided implant placement was performed. Buccal and lingual bone and implant nerve distance were measured by three examiners in preoperative MRI and postoperative CBCT. The implant position was assessed using a software for deviation of implant positions displayed in CBCT and optical scans, respectively. RESULTS: MRI displayed relevant structures for implant planning such as cortical and cancellous bone, inferior alveolar nerve and neighboring teeth. Implant planning, CAD/CAM of drill guides and guided implant placement were performed. Deviations between planned and actual implant positions in postoperative CBCT and optical scans were 1.34 mm (SD 0.84 mm) and 1.03 mm (SD 0.46 mm) at implant shoulder; 1.41 mm (SD 0.88 mm) and 1.28 mm (SD 0.52 mm) at implant apex, and 4.84° (SD 3.18°) and 4.21° (SD 2.01°). Measurements in preoperative MRI and postoperative CBCT confirmed the compliance with minimum distances of implants to anatomical structures. CONCLUSIONS: Relevant anatomical structures for imaging diagnostics in implant dentistry are displayed with MRI. The accuracy of MRI-based fully guided implant placement in vitro is comparable to the workflow using CBCT.


Subject(s)
Dental Implants , Surgery, Computer-Assisted , Computer-Aided Design , Cone-Beam Computed Tomography , Dental Implantation, Endosseous , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Mandible , Patient Care Planning
20.
Clin Oral Implants Res ; 31(6): 575-583, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32105363

ABSTRACT

OBJECTIVES: To present a workflow of virtual implant planning and guided implant surgery with magnetic resonance imaging (MRI) and virtual dental models without the use of ionizing radiation. METHODS: Five patients scheduled for implant placement underwent an MR examination at three Tesla using individualized 2D and 3D turbo spin-echo (TSE) sequences and dedicated head coils. The MRI data and virtual dental models derived from either optical model scans or intraoral scans were imported to a virtual implant planning software (coDiagnostiX, Dental Wings, Montreal, Canada). Virtual prosthetic planning and implant planning were performed regarding the hard and soft tissue anatomy. A drill guide was designed on the virtual dental model using computer-aided design (CAD) and manufactured in-house, using a 3D printer (Eden 260V, Stratasys, Eden Prairie, MN, USA). RESULTS: The MRI displayed all relevant anatomical structures for dental implant planning such as cortical and cancellous bone, floor of the nasal and maxillary sinus, inferior alveolar nerve and neighboring teeth. The manual alignment of virtual dental models with the MRI was possible using anatomical landmarks. Dental implant planning, CAD/CAM of a drill guide and fully guided implant placement were successfully performed. CONCLUSIONS: Guided implant surgery is feasible with MRI without ionizing radiation. Further studies will have to be conducted to study the accuracy of the presented protocol and compare it to the current workflow of guided surgery using CBCT.


Subject(s)
Dental Implants , Surgery, Computer-Assisted , Animals , Computer-Aided Design , Cone-Beam Computed Tomography , Dental Implantation, Endosseous , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Patient Care Planning
SELECTION OF CITATIONS
SEARCH DETAIL
...