Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Orv Hetil ; 159(17): 671-676, 2018 Apr.
Article in Hungarian | MEDLINE | ID: mdl-29681179

ABSTRACT

INTRODUCTION AND AIM: To present our results on femtosecond laser-assisted penetrating keratoplasty. PATIENTS AND METHOD: Twenty-five eyes of 25 patients underwent surgery with the following indications: pseudophakic bullous keratopathy (n = 10), keratoconus (n = 4), corneal dystrophy (n = 5), corneal scar (n = 4), band keratopathy (n = 2). Trephination of both the donor and recipient corneas were performed with VisuMax femtosecond laser device (Carl Zeiss Meditec AG, Jena, Germany). In each case, trephinaton of the donor tissue was performed first with an artificial anterior chamber (Moria, Antony, France). For the surgical plan and in the postoperative period we obtained different corneal imaging modalities. The corneal power was measured with corneal topography (TMS-4, Tomey, Nürnberg, Germany) and Scheimpflug tomography (Pentacam HR, Oculus, Wetzlar, Germany). The central corneal thickness was evaluated with Pentacam and corneal endothelial cell density was measured with specular microscopy (SP3000P, Topcon, Tokyo, Japan). The corneal structure was imaged with anterior segment optical coherence tomography (Visante, Carl Zeiss Meditec AG). All measurements were performed every 3 months in the first year and yearly thereafter. The follow-up period was 3 years in every case. RESULTS: The corrected decimal visual acuity showed an improvement from a preoperative 0.1 ± 0.1 to a postoperative 0.71 ± 0.18 value at the end of the follow-up period (p = 0.03). All corneal grafts maintained their transparency, there were no immunological rejection during the follow-up. Topographical astigmatism was 4.5 ± 3.1 D in the first month; it showed a decreasing tendency, but there was no significant change in the 3-year period. The mean central corneal thickness changed with 60 µm during the follow-up; there was no significant difference between the first month (564 ± 52 µm) and the third year (596 ± 64 µm) mean pachymetry values (p = 0.1). The mean endothelial cell density decreased first, then remained stable, but did not change significantly from the first (1641 ± 433 cells/mm2) to the last postoperative visit (1220 ± 391 cells/mm2, p = 0.1). CONCLUSIONS: In the case of femtosecond laser-assisted penetrating keratoplasty, trephination of the donor and recipient cornea is performed automatically in a highly precise fashion. The accurate cutting surface provides excellent wound apposition and healing. Both anatomical and functional rehabilitation of patients undergoing surgery are favourable and fast. Orv Hetil. 2018; 159(17): 671-676.


Subject(s)
Corneal Diseases/surgery , Keratoplasty, Penetrating/methods , Laser Therapy/methods , Visual Acuity , Corneal Dystrophies, Hereditary/surgery , Female , Follow-Up Studies , Humans , Keratoconus/surgery , Male , Tissue Donors , Treatment Outcome
2.
Int J Ophthalmol ; 9(2): 235-8, 2016.
Article in English | MEDLINE | ID: mdl-26949641

ABSTRACT

AIM: To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS: Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43±21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41±40.17mo (range: 11-128mo) after the keratoplasty and after 7.64±2.34mo (range: 5-14mo) of suture removal. RESULTS: Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION: The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty.

SELECTION OF CITATIONS
SEARCH DETAIL
...