Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Proteomics ; 21(6): e2000224, 2021 03.
Article in English | MEDLINE | ID: mdl-33471423

ABSTRACT

We described a targeted mass spectrometry assay based on selected reaction monitoring (SRM) for five apolipoproteins (apoA1, apoB, apoJ, apoD, and apoE) in plasma lipoproteins isolated by anion exchange fast protein liquid chromatography using only 100 µL of plasma. We performed analytical characterization of the SRM assay and evaluated reproducibility of the entire workflow. The limit of detections for apoA1, apoB, apoD, apoJ, and apoE were 0.6, 4.6, 0.8, 1.2, and 0.7 nM, respectively; the limit of quantifications was 8.3 nM for all peptides except apoD (4.2 nM). The SRM assay was linear from 0.4 to 1667 nM. The intra-day and inter-day and total repeatability (CV%) of the assay ranged from 2.2% to 21.7% for all five peptides. The intra-day and inter-day and total reproducibility of the entire workflow ranged from 12.2% to 43.9% for all five peptides in fractionated high-density lipoprotein, low-density lipoprotein, and IDL. In the future, we will apply this workflow to investigate the association of fractionated plasma lipoproteins with amyloid deposition and cognitive changes in the context of Alzheimer's disease.


Subject(s)
Apolipoproteins E , Anions , Chromatography, High Pressure Liquid , Humans , Mass Spectrometry , Reproducibility of Results
2.
Sci Rep ; 10(1): 8759, 2020 05 29.
Article in English | MEDLINE | ID: mdl-32472068

ABSTRACT

Traditional manual gating strategies are often time-intensive, place a high burden on the analyzer, and are susceptible to bias between analyzers. Several automated gating methods have shown to exceed performance of manual gating for a limited number of cell subsets. However, many of the automated algorithms still require significant manual interventions or have yet to demonstrate their utility in large datasets. Therefore, we developed an approach that utilizes a previously published automated algorithm (OpenCyto framework) with a manually created hierarchically cell gating template implemented, along with a custom developed visualization software (FlowAnnotator) to rapidly and efficiently analyze immunophenotyping data in large population studies. This approach allows pre-defining populations that can be analyzed solely by automated analysis and incorporating manual refinement for smaller downstream populations. We validated this method with traditional manual gating strategies for 24 subsets of T cells, B cells, NK cells, monocytes and dendritic cells in 931 participants from the Health and Retirement Study (HRS). Our results show a high degree of correlation (r ≥ 0.80) for 18 (78%) of the 24 cell subsets. For the remaining subsets, the correlation was low (<0.80) primarily because of the low numbers of events recorded in these subsets. The mean difference in the absolute counts between the hybrid method and manual gating strategy of these cell subsets showed results that were very similar to the traditional manual gating method. We describe a practical method for standardization of immunophenotyping methods in large scale population studies that provides a rapid, accurate and reproducible alternative to labor intensive manual gating strategies.


Subject(s)
Flow Cytometry/methods , Immunophenotyping/standards , Software , Algorithms , Computational Biology , Datasets as Topic , Dendritic Cells , Feasibility Studies , Health Surveys , High-Throughput Screening Assays , Humans , Immunophenotyping/methods , Longitudinal Studies , Lymphocyte Subsets/classification , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...