1.
Vet Rec ; 159(17): 547-51, 2006 Oct 21.
Article in English | MEDLINE | ID: mdl-17056650

ABSTRACT

A double-blind, randomised, controlled, multicentre field study was conducted to compare the safety and efficacy of firocoxib chewable tablets and carprofen tablets in 218 dogs with osteoarthritis. Firocoxib is a non-steroidal anti-inflammatory drug with more than 350-fold selectivity in dogs for the inducible isoform of the enzyme cyclo-oxygenase-2. The efficacy, tolerance and ease of administration of firocoxib (5 mg/kg/day) and carprofen (4 mg/kg/day) were assessed by the owners and the attending veterinarians during 30 days of treatment. The efficacy was assessed in terms of the dogs' overall scores at the end of the treatment, based on the veterinarians' assessment of lameness, pain on manipulation/palpation, range of motion, and joint swelling; 92.5 per cent of the dogs treated with firocoxib and 92.4 per cent of the dogs treated with carprofen had improved. The reduction in lameness in the dogs treated with firocoxib was significantly greater than in the dogs treated with carprofen. The owners' evaluations were that 96.2 per cent of the dogs treated with firocoxib and 92.4 per cent of the dogs treated with carprofen had improved, and this difference was statistically significant.


Subject(s)
4-Butyrolactone/analogs & derivatives , Anti-Inflammatory Agents, Non-Steroidal/therapeutic use , Carbazoles/therapeutic use , Dog Diseases/drug therapy , Osteoarthritis/veterinary , Sulfones/therapeutic use , 4-Butyrolactone/administration & dosage , 4-Butyrolactone/therapeutic use , Animals , Anti-Inflammatory Agents, Non-Steroidal/administration & dosage , Carbazoles/administration & dosage , Dogs , Double-Blind Method , Female , Male , Osteoarthritis/drug therapy , Sulfones/administration & dosage , Tablets , Treatment Outcome
2.
Pediatr Cardiol ; 26(2): 169-75, 2005.
Article in English | MEDLINE | ID: mdl-15868323

ABSTRACT

Hybrid procedures are becoming increasingly important, especially in the management of congenital heart lesions for which there are no ideal surgical or interventional options. This report describes a multicenter experience with perventricular muscular venticular septal defect (VSD) device closure. Three groups of patients (n = 12) were identified: infants with isolated muscular VSDs (n = 2), neonates with aortic coarctation and muscular VSDs (n = 3) or patients with muscular VSDs and other complex cardiac lesions (n = 2), and patients with muscular VSDs and pulmonary artery bands (n = 5). Via a sternotomy or a subxyphoid approach, the right ventricle (RV) free wall was punctured under transesophageal echocardiography guidance. A guidewire was introduced across the largest defect. A short delivery sheath was positioned in the left ventricle cavity. An Amplatzer muscular VSD occluding device was deployed across the VSD. Cardiopulmonary bypass was needed only for repair of concomitant lesions, such as double-outlet right ventricle, aortic coarctation, or pulmonary artery band removal. No complications were encountered using this technique. Discharge echocardiograms showed either mild or no significant shunting across the ventricular septum. At a median follow-up of 12 months, all patients were asymptomatic and 2 patients had mild residual ventricular level shunts. Perventricular closure of muscular VSDs is safe and effective for a variety of patients with muscular VSDs.


Subject(s)
Heart Defects, Congenital/surgery , Heart Septal Defects, Ventricular/surgery , Balloon Occlusion , Cardiac Catheterization , Cardiovascular Surgical Procedures , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/physiopathology , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/physiopathology , Humans , Infant , Risk Factors , Ultrasonography
3.
Echocardiography ; 18(5): 433-43, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11466156

ABSTRACT

This article details the important contribution of three-dimensional echocardiography for catheterization device closure of secundum atrial septal defects. Aspects presented include three-dimensional echocardiographic application in preselection of patients and in selection of the type and size of the atrial septal occluder devices. Unique three-dimensional echocardiographic imaging planes are shown that depict the size and shape of the defect, the important rim tissue surrounding the defect, and the images that demonstrate successful device placement. Details of the acquisition phase, digital reformatting, and the eventual rendering of standard three-dimensional echocardiographic imaging planes of the atrial septum are shown. Three-dimensional echocardiography not only provides important additional information, but also enhances understanding of standard two-dimensional studies.


Subject(s)
Echocardiography, Three-Dimensional , Heart Septal Defects, Atrial/diagnostic imaging , Cardiac Catheterization/instrumentation , Heart Septal Defects, Atrial/therapy , Humans
4.
J Am Soc Echocardiogr ; 13(3): 171-6, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10708465

ABSTRACT

We evaluated the ability of real-time 3-dimensional (RT3D) echocardiography to diagnose congenital heart defects and its potential for presenting structural abnormalities in novel views. Seventy-five patients with suspected congenital heart defects were examined with the use of RT3D echocardiography. Images were reviewed off-line as multiple slices of the raw data or as volume-rendered images by a blinded observer. Diagnoses made from blinded review of the RT3D images were compared with the clinical report of the 2D echocardiogram obtained at the same visit. Real-time 3D echocardiography identified all structural abnormalities except for small atrial septal defects in 2 patients and coronary artery anatomy in D-transposition of the great arteries. Less than 5 minutes were needed to acquire RT3D images in all cases, and sedation was never required. Unique region-oriented views obtained from the 3D data set can be acquired quickly and have the potential to enhance understanding of complex cardiac anatomy.


Subject(s)
Echocardiography, Three-Dimensional , Heart Defects, Congenital/diagnostic imaging , Adolescent , Child , Child, Preschool , Diagnosis, Differential , Humans , Infant , Infant, Newborn , Observer Variation , Reproducibility of Results , Video Recording
5.
Echocardiography ; 17(8): 773-9, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11153029

ABSTRACT

The heart is a dynamic organ with complexities in its shape. As such, it places special demands on three-dimensional techniques for reconstruction. Real-time volumetric echocardiography, which is based on phased array and parallel processing principles to enhance line density within a scan volume, provides rapid image acquisition. We introduce the principle, potential clinical importance, current limitations, and future of volumetric imaging methods.


Subject(s)
Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Valve Diseases/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Humans , Sensitivity and Specificity
6.
Am Heart J ; 137(5): 958-66, 1999 May.
Article in English | MEDLINE | ID: mdl-10220647

ABSTRACT

BACKGROUND: The asymmetry and complex shape of the right ventricle have made it difficult to determine right ventricular (RV) volume with 2-dimensional echocardiography. Three-dimensional cardiac imaging improves visualization of cardiac anatomy but is also complex and time consuming. A newly developed volumetric scanning system holds promise of obviating past limitations. METHODS: Real-time, transthoracic 3-dimensional echocardiographic images of the right ventricle were obtained with a high-speed volumetric ultrasound system that uses a 16:1 parallel processing schema from a 2.5 MHz matrix phased-array scanner to interrogate an entire pyramidal volume in real time. The instrumentation was used to measure RV volume in 8 excised canine hearts; dynamic real-time 3-dimensional images were also obtained from 14 normal subjects. RESULTS: Three-dimensional images were obtained in vitro and in vivo during intravenous hand-agitated saline injection to determine RV volumes. The RV volumes by real-time 3-dimensional echocardiography are well correlated with those of drained in vitro (y = 1.26x - 9.92, r = 0.97, P <.0001, standard error of the estimate = 3.26 mL). For human subjects, the end-diastolic and end-systolic RV volumes were calculated by tracing serial cross-sectional, inclined C scans; functional data were validated by comparing the scans with conventional 2-dimensional echocardiographic indexes of left ventricular stroke volume. CONCLUSIONS: These data indicate that RV volume measurements of excised heart by real-time 3-dimensional echocardiography are accurate and that beat-to-beat RV quantitative measurement applying this imaging method is possible. The new application of real-time 3-dimensional echocardiography presents the opportunity to develop new descriptors of cardiac performance.


Subject(s)
Contrast Media/administration & dosage , Echocardiography, Three-Dimensional , Heart Ventricles/diagnostic imaging , Sodium Chloride , Ventricular Function, Right/physiology , Animals , Dogs , Feasibility Studies , Humans , Injections, Intravenous , Reference Values , Reproducibility of Results , Sodium Chloride/administration & dosage
7.
Circulation ; 97(19): 1897-900, 1998 May 19.
Article in English | MEDLINE | ID: mdl-9609081

ABSTRACT

BACKGROUND: The lack of a suitable noninvasive method for assessing right ventricular (RV) volume and function has been a major deficiency of two-dimensional (2D) echocardiography. The aim of our animal study was to test a new real-time three-dimensional (3D) echo imaging system for evaluating RV stroke volumes. METHODS AND RESULTS: Three to 6 months before hemodynamic and 3D ultrasonic study, the pulmonary valve was excised from 6 sheep (31 to 59 kg) to induce RV volume overload. At the subsequent session, a total of 14 different steady-state hemodynamic conditions were studied. Electromagnetic (EM) flow probes were used for obtaining aortic and pulmonic flows. A unique phased-array volumetric 3D imaging system developed at the Duke University Center for Emerging Cardiovascular Technology was used for ultrasonic imaging. Real-time volumetric images of the RV were digitally stored, and RV stroke volumes were determined by use of parallel slices of the 3D RV data set and subtraction of end-systolic cavity volumes from end-diastolic cavity volumes. Multiple regression analyses showed a good correlation and agreement between the EM-obtained RV stroke volumes (range, 16 to 42 mL/beat) and those obtained by the new real-time 3D method (r=0.80; mean difference, -2.7+/-6.4 mL/beat). CONCLUSIONS: The real-time 3D system provided good estimation of strictly quantified reference RV stroke volumes, suggesting an important application of this new 3D method.


Subject(s)
Echocardiography, Three-Dimensional , Hemodynamics , Ventricular Dysfunction, Right/physiopathology , Ventricular Function, Right , Animals , Electromagnetic Fields , Humans , Observer Variation , Regression Analysis , Reproducibility of Results , Sheep , Stroke Volume , Ventricular Dysfunction, Right/diagnostic imaging
8.
Am J Gastroenterol ; 92(10): 1867-71, 1997 Oct.
Article in English | MEDLINE | ID: mdl-9382054

ABSTRACT

OBJECTIVES: The aim of this study was to compare the efficacy of mesalamine rectal suspension enema (Rowasa) alone, oral mesalamine tablets (Asacol) alone, and the combination of mesalamine enema and mesalamine tablets in patients with active mild-to-moderate distal ulcerative colitis. METHODS: Sixty outpatients with ulcerative colitis at least 5 cm above the anal verge and not more than 50 cm, inclusive, and a total disease activity index (DAI) score between 4 and 10, inclusive, were randomized to either mesalamine rectal enema (n = 18) once nightly, oral mesalamine 2.4 g/day (n = 22), or a combination of both treatments (n = 20). Placebo capsules and enemas were used to maintain a blind procedure. Total DAI scores and abbreviated DAI scores were evaluated at wk 3 and 6, and wk 1 and 2, respectively. Patients recorded the amount of blood in stools, urgency, straining at stools, and abdominal pain in daily diaries. Physicians and patients rated overall improvement at each visit. RESULTS: At wk 6, combination therapy produced a greater improvement (-5.2) in total DAI scores than did either mesalamine enema (-4.4) or mesalamine tablet (-3.9) therapy alone; similar treatment differences were observed at wk 3. Compared with patients given mesalamine enemas or mesalamine tablets, combination-therapy patients reported an absence of blood in stools significantly sooner and, at all visits, the combination therapy group had the highest percentage of patients who reported no blood in their stools. Physicians' and patients' ratings of improvement indicated that combination therapy significantly improved disease status, compared with mesalamine tablet therapy alone. All treatments were well tolerated. CONCLUSIONS: The combination of oral and rectal mesalamine therapy was well tolerated and produced earlier and more complete relief of rectal bleeding than oral or rectal therapy alone.


Subject(s)
Anti-Inflammatory Agents, Non-Steroidal/administration & dosage , Colitis, Ulcerative/drug therapy , Mesalamine/administration & dosage , Administration, Oral , Administration, Rectal , Adult , Double-Blind Method , Enema , Female , Humans , Male , Mesalamine/adverse effects , Tablets , Treatment Outcome