Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
ACS Comb Sci ; 22(4): 197-203, 2020 04 13.
Article in English | MEDLINE | ID: mdl-32119524

ABSTRACT

Characterization of photovoltaic (PV) module materials throughout different stages of service life is crucial to understanding and improving the durability of these materials. Currently the large-scale of PV modules (>1 m2) is imbalanced with the small-scale of most materials characterization tools (≤1 cm2). Furthermore, understanding degradation mechanisms often requires a combination of multiple characterization techniques. Here, we present adaptations of three standard materials characterization techniques to enable mapping characterization over moderate sample areas (≥25 cm2). Contact angle, ellipsometry, and UV-vis spectroscopy are each adapted and demonstrated on two representative samples: a commercial multifunctional coating for PV glass and an oxide combinatorial sample library. Best practices are discussed for adapting characterization techniques for large-area mapping and combining mapping information from multiple techniques.


Subject(s)
Combinatorial Chemistry Techniques , Electric Power Supplies , Solar Energy , Glass/chemistry , Materials Testing
2.
J Mech Behav Biomed Mater ; 79: 314-323, 2018 03.
Article in English | MEDLINE | ID: mdl-29353775

ABSTRACT

The number of revision joint replacements has been increasing substantially over the last few years. Understanding their failure mechanism is extremely important for improving the design and material selection of current implants. This study includes ten retrieved and four new mildly cross-linked ultra-high molecular weight polyethylene (UHMWPE) acetabular liners. Among them, most of the prostheses (n = 5) were reported to be revised and replaced due to aseptic loosening, followed by painful joint (n = 2), dislocation (n = 1), intra articular ossification (n = 1), combination of wear (liner) and osteolysis (stem) (n=1). Surface deviations (wear, material inflation and roughness), oxidative degradation and change of material properties were measured using micro-computed tomography (micro-CT) scan, 3D laser scanning microscopy, raman spectroscopy and nanoindentation, respectively. Prostheses having eccentric worn areas had much higher linear wear rates (228.01 ± 35.51µm/year) compared to that of centrically worn prostheses (96.71 ± 10.83µm/year). Oxidation index (OI) showed similar trends to the surface penetration depth. Among them, sample 10 exhibited the highest OI across the contact area and the rim of the cup liner. It also had the lowest hardness/elasticity ratio. Overall, wear and creep, oxidative degradation and reduced hardness/elasticity ratio all contributed to the premature failure of the UHMWPE acetabular cup liners.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Aged , Female , Humans , Male , Materials Testing , Middle Aged , Polyethylenes/chemistry , Prosthesis Failure
3.
J Mech Behav Biomed Mater ; 68: 51-61, 2017 04.
Article in English | MEDLINE | ID: mdl-28152443

ABSTRACT

Six types of diamond-like carbon (DLC) coatings with zirconium (Zr)-containing interlayers on titanium alloy (Ti-6Al-4V) were investigated for improving the biotribological performance of orthopedic implants. The coatings consist of three layers: above the substrate a layer stack of 32 alternating Zr and ZrN sublayers (Zr:ZrN), followed by a layer comprised of Zr and DLC (Zr:DLC), and finally a N-doped DLC layer. The Zr:ZrN layer is designed for increasing load carrying capacity and corrosion resistance; the Zr:DLC layer is for gradual transition of stress, thus enhancing layer adhesion; and the N-doped DLC layer is for decreasing friction, squeaking noises and wear. Biotribological experiments were performed in simulated body fluid employing a ball-on-disc contact with a Si3N4 ball and a rotational oscillating motion to mimic hip motion in terms of gait angle, dynamic contact pressures, speed and body temperature. The results showed that the Zr:DLC layer has a substantial influence on eliminating delamination of the DLC from the substrates. The DLC/Si3N4 pairs significantly reduced friction coefficient, squeaking noise and wear of both the Si3N4 balls and the discs compared to those of the Ti-6Al-4V/Si3N4 pair after testing for a duration that is equivalent to one year of hip motion in vivo.


Subject(s)
Carbon/chemistry , Materials Testing , Prostheses and Implants , Titanium/chemistry , Zirconium/chemistry , Alloys , Corrosion , Diamond , Hip Prosthesis , Humans , Surface Properties , Weight-Bearing
SELECTION OF CITATIONS
SEARCH DETAIL