1.
IEEE Trans Med Imaging ; PP2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38640053

ABSTRACT

3D Imaging of the human heart at high frame rate is of major interest for various clinical applications. Electronic complexity and cost has prevented the dissemination of 3D ultrafast imaging into the clinic. Row column addressed (RCA) transducers provide volumetric imaging at ultrafast frame rate by using a low electronic channel count, but current models are ill-suited for transthoracic cardiac imaging due to field-of-view limitations. In this study, we proposed a mechanically curved RCA with an aperture adapted for transthoracic cardiac imaging (24 × 16 mm²). The RCA has a toroidal curved surface of 96 elements along columns (curvature radius rC = 4.47 cm) and 64 elements along rows (curvature radius rR = 3 cm). We implemented delay and sum beamforming with an analytical calculation of the propagation of a toroidal wave which was validated using simulations (Field II). The imaging performance was evaluated on a calibrated phantom. Experimental 3D imaging was achieved up to 12 cm deep with a total angular aperture of 30° for both lateral dimensions. The Contrast-to-Noise ratio increased by 12 dB from 2 to 128 virtual sources. Then, 3D Ultrasound Localization Microscopy (ULM) was characterized in a sub-wavelength tube diameter. Finally, 3D ULM was demonstrated on a perfused ex-vivo swine heart to image the coronary microcirculation.

2.
Article in English | MEDLINE | ID: mdl-37224371

ABSTRACT

Centimeter-sized BaTiO3-based crystals grown by top-seeded solution growth from the BaTiO3-CaTiO3-BaZrO3 system were used to process a high-frequency (HF) lead-free linear array. Piezoelectric plates with (110)pc cut within 1° accuracy were used to manufacture two 1-3 piezo-composites with thicknesses of 270 and [Formula: see text] for resonant frequencies in air of 10 and 30 MHz, respectively. The electromechanical characterization of the BCTZ crystal plates and the 10-MHz piezocomposite yielded the thickness coupling factors of 40% and 50%, respectively. We quantified the electromechanical performance of the second piezocomposite (30 MHz) according to the reduction in the pillar sizes during the fabrication process. The dimensions of the piezocomposite at 30 MHz were sufficient for a 128-element array with a 70- [Formula: see text] element pitch and a 1.5-mm elevation aperture. The transducer stack (backing, matching layers, lens, and electrical components) was tuned with the characteristics of the lead-free materials to deliver optimal bandwidth and sensitivity. The probe was connected to a real-time HF 128-channel echographic system for acoustic characterization (electroacoustic response and radiation pattern) and to acquire high-resolution in vivo images of human skin. The center frequency of the experimental probe was 20 MHz, and the fractional bandwidth at -6 dB was 41%. Skin images were compared against those obtained with a lead-based 20-MHz commercial imaging probe. Despite significant differences in sensitivity between elements, in vivo images obtained with a BCTZ-based probe convincingly demonstrated the potential of integrating this piezoelectric material in an imaging probe.

3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4123-4127, 2021 11.
Article in English | MEDLINE | ID: mdl-34892134

ABSTRACT

A pulse wave velocity (PWV) measurement method performed above a small blood vessel using an ultrasonic probe is studied and reported in this paper. These experimentations are carried out using a high-frequency probe (14-22 MHz), allowing a high level of resolution compatible with the vessel dimensions, combined with an open research ultrasound scanner. High frame-rate (HFR) imaging (10 000 frames per second) is used for a precise PWV estimation. The measurements are performed in-vivo on a healthy volunteer. The probe is placed above the ulnar artery on the wrist in order to make longitudinal scans. In addition to conventional duplex ultrasound evaluation, the measurement of the PWV using this method at this location could strengthen the detection and diagnosis of cardiovascular diseases (CVDs), in particular for arm artery diseases (AADs). Moreover, these experimentations are also carried out within the scope of a demonstration for a potential miniaturized and wearable device (i.e., a probe with fewer elements, typically less than 32, and its associated electronics). The study has shown results coherent with expected PWV and also promising complementary results such as intima-media thickness (IMT) with spatiotemporal resolution on the order of 6.2 µm and 0.1 ms.


Subject(s)
Carotid Intima-Media Thickness , Pulse Wave Analysis , Humans , Ulnar Artery/diagnostic imaging , Ultrasonics , Wrist/diagnostic imaging
4.
IEEE Trans Med Imaging ; 39(6): 1884-1893, 2020 06.
Article in English | MEDLINE | ID: mdl-31841403

ABSTRACT

Functional ultrasound imaging (fUS) recently emerged as a promising neuroimaging modality to image and monitor brain activity based on cerebral blood volume response (CBV) and neurovascular coupling. fUS offers very good spatial and temporal resolutions compared to fMRI gold standard as well as simplicity and portability. It was recently extended to 4D fUS imaging in preclinical settings although this approach remains limited and complex. Indeed 4D fUS requires a 2D matrix probe and specific hardware able to drive the N2 elements of the probe with thousands of electronic channels. Several under-sampling approaches are currently investigated to limit the channel count and spread ultrasound 4D modalities. Among them, the Row Column Addressing (RCA) approach combined with ultrafast imaging is a compelling alternative using only N + N channels. We present a large field of view RCA probe prototype of 128 + 128 channels and 15 MHz central frequency adapted for preclinical imaging. Based on the Orthogonal Plane Wave compounding scheme, we were able to perform 4D vascular brain acquisitions at high volume rate. Doppler volumes of the whole rat brain were obtained in vivo at high rates (23 dB CNR at 156 Hz and 19 dB CNR at 313 Hz). Visual and whiskers stimulations were performed and the corresponding CBV increases were reconstructed in 3D with successful functional activation detected in the superior colliculus and somato-sensorial cortex respectively. This proof of concept study demonstrates for the first time the use of a low-channel count RCA array for in vivo 4D fUS imaging in the whole rat brain.


Subject(s)
Neuroimaging , Ultrasonography, Doppler , Animals , Brain/diagnostic imaging , Imaging, Three-Dimensional , Rats , Ultrasonography
5.
Can J Psychiatry ; 48(4): 265-71, 2003 May.
Article in English | MEDLINE | ID: mdl-12776394

ABSTRACT

BACKGROUND: Several pharmacotherapeutic approaches have confirmed the influence of neuroendocrine parameters on sexual desire, function, and fantasies in men; however, the relevance of acute neuroendocrine changes in mediating heightened sexual drive remains unknown. We recently demonstrated that plasma prolactin substantially increases following orgasm in healthy men, suggesting a feedback mechanism for peripheral prolactin in the control of acute sexual arousal. Because prolactin appears to play a regulatory role in acute sexual drive, we initiated this study to see whether sexual offenders with a high sexual drive have a different neuroendocrine response to sexual arousal. This study compares the prolactin response to orgasm of sexual offenders with high sexual drive and that of healthy subjects with average sexual drive. METHODS: From a subject pool of 150 inpatients held because of sexual crimes, we recruited 10 volunteers, based on their high sexual drive according to an intensive, semistructured clinical interview. We defined sexual drive by a short refractory period and strong sexualization, or a high frequency of sexual stimulation. We analyzed the acute psychoneuroendocrine response to sexual arousal and orgasm continuously before, during, and after masturbation-induced orgasm in patients and control subjects. RESULTS: Sexual offenders demonstrated higher sexual desire (P < 0.001) and function (P < 0.001) and a more positively perceived refractory period (P < 0.05). Both groups displayed a prolonged, significant increase in prolactin plasma levels after orgasm (P < 0.001). Sexual offenders did not differ from control subjects in neuroendocrine response to sexual arousal and orgasm. CONCLUSIONS: These data demonstrate that sexual offenders with a high sexual drive do not differ from control subjects in the postorgasmic neuroendocrine response, particularly in prolactin release. This study confirms that factors other than peripheral hormones influence deviant sexual behaviour.


Subject(s)
Follicle Stimulating Hormone/metabolism , Heart Rate/physiology , Hydrocortisone/metabolism , Luteinizing Hormone/metabolism , Masturbation/psychology , Orgasm/physiology , Prolactin/metabolism , Sex Offenses/psychology , Testosterone/metabolism , Adult , Follicle Stimulating Hormone/blood , Humans , Hydrocortisone/blood , Libido , Luteinizing Hormone/blood , Male , Prolactin/blood , Testosterone/blood