Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Heart Rhythm ; 9(3): 342-6, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22001710

ABSTRACT

BACKGROUND: There is controversy whether proceduralist-directed, nurse-administered propofol sedation (PDNAPS) is safe. OBJECTIVE: To assess the frequency of adverse events when PDNAPS is used for implantable cardioverter-defibrillator (ICD)-related procedures and to determine the patient and procedural characteristics associated with adverse events. METHODS: Consecutive ICD-related procedures using PDNAPS from May 2006 to July 2009 at a tertiary-care hospital were evaluated. Serious adverse events were defined as procedural death, unexpected transfer to an intensive care unit, respiratory failure requiring intubation/bag-mask ventilation, or hypotension requiring vasoconstrictor/inotrope support. Nonserious adverse events were defined as hypotension requiring fluid resuscitation or hypoxemia requiring augmented respiratory support with non-rebreather mask, oral airway, or jaw lift. RESULTS: Of 582 patients (age 64 ± 14 years, 72.3% males) undergoing ICD-related procedures using PDNAPS, 58 (10.0%) patients had serious adverse events with no procedural death and 225 (38.7%) had nonserious adverse events. Longer procedure duration (relative risk [RR] = 2.1 per hour; 95% confidence interval [CI] = 1.6-2.8; P < .001) and biventricular implant (RR = 2.7; CI = 1.4-5.3; P = .003) were independent predictors of serious adverse events. A longer procedure duration (RR = 1.4 per hour; CI = 1.1-1.7; P = .001), heart failure class (RR = 1.4 per 1 class; CI = 1.1-1.7; P = .002), and use of propofol infusion (RR = 3.5; CI = 2.2-5.7; P < .001) were independent predictors of nonserious adverse events. CONCLUSION: PDNAPS for shorter ICD procedures including single- and dual-chamber implants, generator changes, and defibrillation threshold testing have acceptable rates of serious adverse events and manageable nonserious adverse events and should be considered for further study. Biventricular implants and other complex procedures should be done with an anesthesiologist.


Subject(s)
Cardiac Pacing, Artificial , Conscious Sedation , Defibrillators, Implantable , Nursing Care/standards , Propofol , Prosthesis Implantation , Aged , Anesthetics, Intravenous/administration & dosage , Anesthetics, Intravenous/adverse effects , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Cardiac Pacing, Artificial/standards , Conscious Sedation/adverse effects , Conscious Sedation/nursing , Female , Humans , Hypotension/etiology , Male , Middle Aged , Outcome Assessment, Health Care , Practice Patterns, Physicians' , Propofol/administration & dosage , Propofol/adverse effects , Prosthesis Implantation/adverse effects , Prosthesis Implantation/instrumentation , Prosthesis Implantation/methods , Respiratory Insufficiency/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...