Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
2.
Circulation ; 137(5): 436-451, 2018 01 30.
Article in English | MEDLINE | ID: mdl-29101287

ABSTRACT

BACKGROUND: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non-ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. METHODS: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non-ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m2, and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. RESULTS: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non-ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P<0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6-100.0] versus 99.2% [95% CI, 97.6-99.8]; P=0.559), lower specificity of rule-in (88.7% [95% CI, 84.8-91.9] versus 96.5% [95% CI, 95.7-97.2]; P<0.001), and lower overall efficacy (51% versus 81%, P<0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P<0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0-99.8] versus 98.5% [95% CI, 96.5-99.5]; P=1.0), lower specificity of rule-in (84.4% [95% CI, 79.9-88.3] versus 91.7% [95% CI, 90.5-92.9]; P<0.001), and lower overall efficacy (54% versus 76%, P<0.001; proportion ruled out, 18% versus 58%, P<0.001) compared with patients with normal renal function. CONCLUSIONS: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00470587.


Subject(s)
Algorithms , Decision Support Techniques , Glomerular Filtration Rate , Kidney Diseases/physiopathology , Kidney/physiopathology , Non-ST Elevated Myocardial Infarction/blood , Non-ST Elevated Myocardial Infarction/diagnosis , Triage , Troponin/blood , Aged , Aged, 80 and over , Biomarkers/blood , Creatinine/blood , Europe/epidemiology , Female , Humans , Kidney Diseases/blood , Kidney Diseases/diagnosis , Kidney Diseases/epidemiology , Male , Middle Aged , Non-ST Elevated Myocardial Infarction/epidemiology , Predictive Value of Tests , Prevalence , Prognosis , Prospective Studies , Reproducibility of Results , Risk Assessment , Risk Factors , Time Factors , Up-Regulation
3.
Circulation ; 135(17): 1597-1611, 2017 Apr 25.
Article in English | MEDLINE | ID: mdl-28283497

ABSTRACT

BACKGROUND: Four strategies for very early rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I (hs-cTnI) have been identified. It remains unclear which strategy is most attractive for clinical application. METHODS: We prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. Hs-cTnI levels were measured at presentation and after 1 hour in a blinded fashion. We directly compared all 4 hs-cTnI-based rule-out strategies: limit of detection (LOD, hs-cTnI<2 ng/L), single cutoff (hs-cTnI<5 ng/L), 1-hour algorithm (hs-cTnI<5 ng/L and 1-hour change<2 ng/L), and the 0/1-hour algorithm recommended in the European Society of Cardiology guideline combining LOD and 1-hour algorithm. RESULTS: Among 2828 enrolled patients, acute myocardial infarction was the final diagnosis in 451 (16%) patients. The LOD approach ruled out 453 patients (16%) with a sensitivity of 100% (95% confidence interval [CI], 99.2%-100%), the single cutoff 1516 patients (54%) with a sensitivity of 97.1% (95% CI, 95.1%-98.3%), the 1-hour algorithm 1459 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%-99.2%), and the 0/1-hour algorithm 1463 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%-99.2%). Predefined subgroup analysis in early presenters (≤2 hours) revealed significantly lower sensitivity (94.2%, interaction P=0.03) of the single cutoff, but not the other strategies. Two-year survival was 100% with LOD and 98.1% with the other strategies (P<0.01 for LOD versus each of the other strategies). CONCLUSIONS: All 4 rule-out strategies balance effectiveness and safety equally well. The single cutoff should not be applied in early presenters, whereas the 3 other strategies seem to perform well in this challenging subgroup. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00470587.


Subject(s)
Acute Coronary Syndrome/diagnosis , Decision Support Techniques , Myocardial Infarction/diagnosis , Troponin I/blood , Acute Coronary Syndrome/blood , Acute Coronary Syndrome/mortality , Adult , Age Factors , Aged , Aged, 80 and over , Algorithms , Biomarkers/blood , Electrocardiography , Europe , Female , Health Status , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/blood , Myocardial Infarction/mortality , Predictive Value of Tests , Prognosis , Prospective Studies , Risk Assessment , Risk Factors , Sex Factors , Time Factors , Up-Regulation
SELECTION OF CITATIONS
SEARCH DETAIL
...