1.
Oral Oncol ; 92: 6-11, 2019 05.
Article in English | MEDLINE | ID: mdl-31010626

ABSTRACT

OBJECTIVES: The diagnosis and management of oral cavity cancers are often complicated by the uncertainty of which patients will undergo malignant transformation, obligating close surveillance over time. However, serial biopsies are undesirable, highly invasive, and subject to inherent issues with poor inter-pathologist agreement and unpredictability as a surrogate for malignant transformation and clinical outcomes. The goal of this study was to develop and evaluate a Multivariate Analytical Risk Index for Oral Cancer (MARIO) with potential to provide non-invasive, sensitive, and quantitative risk assessments for monitoring lesion progression. MATERIALS AND METHODS: A series of predictive models were developed and validated using previously recorded single-cell data from oral cytology samples resulting in a "continuous risk score". Model development consisted of: (1) training base classification models for each diagnostic class pair, (2) pairwise coupling to obtain diagnostic class probabilities, and (3) a weighted aggregation resulting in a continuous MARIO. RESULTS AND CONCLUSIONS: Diagnostic accuracy based on optimized cut-points for the test dataset ranged from 76.0% for Benign, to 82.4% for Dysplastic, 89.6% for Malignant, and 97.6% for Normal controls for an overall MARIO accuracy of 72.8%. Furthermore, a strong positive relationship with diagnostic severity was demonstrated (Pearson's coefficient = 0.805 for test dataset) as well as the ability of the MARIO to respond to subtle changes in cell composition. The development of a continuous MARIO for PMOL is presented, resulting in a sensitive, accurate, and non-invasive method with potential for enabling monitoring disease progression, recurrence, and the need for therapeutic intervention of these lesions.


Subject(s)
Cytodiagnosis , Mouth Neoplasms/diagnosis , Biopsy , Cytodiagnosis/instrumentation , Cytodiagnosis/methods , Cytodiagnosis/standards , Humans , Lab-On-A-Chip Devices , Multivariate Analysis , Neoplasm Grading , Neoplasm Staging , Reproducibility of Results , Risk Assessment
2.
Oral Oncol ; 60: 103-11, 2016 09.
Article in English | MEDLINE | ID: mdl-27531880

ABSTRACT

UNLABELLED: Despite significant advances in surgical procedures and treatment, long-term prognosis for patients with oral cancer remains poor, with survival rates among the lowest of major cancers. Better methods are desperately needed to identify potential malignancies early when treatments are more effective. OBJECTIVE: To develop robust classification models from cytology-on-a-chip measurements that mirror diagnostic performance of gold standard approach involving tissue biopsy. MATERIALS AND METHODS: Measurements were recorded from 714 prospectively recruited patients with suspicious lesions across 6 diagnostic categories (each confirmed by tissue biopsy -histopathology) using a powerful new 'cytology-on-a-chip' approach capable of executing high content analysis at a single cell level. Over 200 cellular features related to biomarker expression, nuclear parameters and cellular morphology were recorded per cell. By cataloging an average of 2000 cells per patient, these efforts resulted in nearly 13 million indexed objects. RESULTS: Binary "low-risk"/"high-risk" models yielded AUC values of 0.88 and 0.84 for training and validation models, respectively, with an accompanying difference in sensitivity+specificity of 6.2%. In terms of accuracy, this model accurately predicted the correct diagnosis approximately 70% of the time, compared to the 69% initial agreement rate of the pool of expert pathologists. Key parameters identified in these models included cell circularity, Ki67 and EGFR expression, nuclear-cytoplasmic ratio, nuclear area, and cell area. CONCLUSIONS: This chip-based approach yields objective data that can be leveraged for diagnosis and management of patients with PMOL as well as uncovering new molecular-level insights behind cytological differences across the OED spectrum.


Subject(s)
Lab-On-A-Chip Devices , Monitoring, Physiologic/methods , Mouth Neoplasms/pathology , Automation , Biopsy/methods , Female , Humans , Male , Prospective Studies
3.
Oral Surg Oral Med Oral Pathol Oral Radiol ; 120(4): 474-82.e2, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26216170

ABSTRACT

OBJECTIVE: Interobserver agreement in the context of oral epithelial dysplasia (OED) grading has been notoriously unreliable and can impose barriers for developing new molecular markers and diagnostic technologies. This paper aimed to report the details of a 3-stage histopathology review and adjudication process with the goal of achieving a consensus histopathologic diagnosis of each biopsy. STUDY DESIGN: Two adjacent serial histologic sections of oral lesions from 846 patients were independently scored by 2 different pathologists from a pool of 4. In instances where the original 2 pathologists disagreed, a third, independent adjudicating pathologist conducted a review of both sections. If a majority agreement was not achieved, the third stage involved a face-to-face consensus review. RESULTS: Individual pathologist pair κ values ranged from 0.251 to 0.706 (fair-good) before the 3-stage review process. During the initial review phase, the 2 pathologists agreed on a diagnosis for 69.9% of the cases. After the adjudication review by a third pathologist, an additional 22.8% of cases were given a consensus diagnosis (agreement of 2 out of 3 pathologists). After the face-to-face review, the remaining 7.3% of cases had a consensus diagnosis. CONCLUSIONS: The use of the defined protocol resulted in a substantial increase (30%) in diagnostic agreement and has the potential to improve the level of agreement for establishing gold standards for studies based on histopathologic diagnosis.


Subject(s)
Mouth Neoplasms/pathology , Pathology, Clinical/methods , Biopsy , Carcinoma in Situ/pathology , Cell Transformation, Neoplastic/pathology , Clinical Trials as Topic , Humans , Mouth Mucosa/pathology , Observer Variation , Precancerous Conditions/pathology
4.
RSC Adv ; 5(60): 48194-48206, 2015.
Article in English | MEDLINE | ID: mdl-26097696

ABSTRACT

Measuring low concentrations of clinically-important biomarkers using porous bead-based lab-on-a-chip (LOC) platforms is critical for the successful implementation of point-of-care (POC) devices. One way to meet this objective is to optimize the geometry of the bead holder, referred to here as a micro-container. In this work, two geometric micro-containers were explored, the inverted pyramid frustum (PF) and the inverted clipped pyramid frustum (CPF). Finite element models of this bead array assay system were developed to optimize the micro-container and bead geometries for increased pressure, to increase analyte capture in porous bead-based fluorescence immunoassays. Custom micro-milled micro-container structures containing an inverted CPF geometry resulted in a 28% reduction in flow-through regions from traditional anisotropically-etched pyramidal geometry derived from Si-111 termination layers. This novel "reduced flow-through" design resulted in a 33% increase in analyte penetration into the bead and twofold increase in fluorescence signal intensity as demonstrated with C-Reactive Protein (CRP) antigen, an important biomarker of inflammation. A consequent twofold decrease in the limit of detection (LOD) and the limit of quantification (LOQ) of a proof-of-concept assay for the free isoform of Prostate-Specific Antigen (free PSA), an important biomarker for prostate cancer detection, is also presented. Furthermore, a 53% decrease in the bead diameter is shown to result in a 160% increase in pressure and 2.5-fold increase in signal, as estimated by COMSOL models and confirmed experimentally by epi-fluorescence microscopy. Such optimizations of the bead micro-container and bead geometries have the potential to significantly reduce the LODs and reagent costs for spatially programmed bead-based assay systems of this type.

5.
Drug Alcohol Depend ; 153: 306-13, 2015 08 01.
Article in English | MEDLINE | ID: mdl-26048639

ABSTRACT

OBJECTIVE: There is currently a gap in on-site drug of abuse monitoring. Current detection methods involve invasive sampling of blood and urine specimens, or collection of oral fluid, followed by qualitative screening tests using immunochromatographic cartridges. While remote laboratories then may provide confirmation and quantitative assessment of a presumptive positive, this instrumentation is expensive and decoupled from the initial sampling making the current drug-screening program inefficient and costly. The authors applied a noninvasive oral fluid sampling approach integrated with the in-development chip-based Programmable bio-nano-chip (p-BNC) platform for the detection of drugs of abuse. METHOD: The p-BNC assay methodology was applied for the detection of tetrahydrocannabinol, morphine, amphetamine, methamphetamine, cocaine, methadone and benzodiazepines, initially using spiked buffered samples and, ultimately, using oral fluid specimen collected from consented volunteers. RESULTS: Rapid (∼10min), sensitive detection (∼ng/mL) and quantitation of 12 drugs of abuse was demonstrated on the p-BNC platform. Furthermore, the system provided visibility to time-course of select drug and metabolite profiles in oral fluids; for the drug cocaine, three regions of slope were observed that, when combined with concentration measurements from this and prior impairment studies, information about cocaine-induced impairment may be revealed. CONCLUSIONS: This chip-based p-BNC detection modality has significant potential to be used in the future by law enforcement officers for roadside drug testing and to serve a variety of other settings, including outpatient and inpatient drug rehabilitation centers, emergency rooms, prisons, schools, and in the workplace.


Subject(s)
Illicit Drugs/analysis , Lab-On-A-Chip Devices , Saliva/chemistry , Substance Abuse Detection/methods , Humans , Single-Blind Method
6.
Biosens Bioelectron ; 42: 653-60, 2013 Apr 15.
Article in English | MEDLINE | ID: mdl-23183187

ABSTRACT

Over the past decade, there has been a growth of interest in the translation of microfluidic systems into real-world clinical practice, especially for use in point-of-care or near patient settings. While initial fabrication advances in microfluidics involved mainly the etching of silicon and glass, the economics of scaling of these materials is not amendable for point-of-care usage where single-test applications force cost considerations to be kept low and throughput high. As such, materials base more consistent with point-of-care needs is required. In this manuscript, the fabrication of a hot embossed, through-hole low-density polyethylene ensembles derived from an anisotropically etched silicon wafer is discussed. This semi-opaque polymer that can be easily sterilized and recycled provides low background noise for fluorescence measurements and yields more affordable cost than other thermoplastics commonly used for microfluidic applications such as cyclic olefin copolymer (COC). To fabrication through-hole microchips from this alternative material for microfluidics, a fabrication technique that uses a high-temperature, high-pressure resistant mold is described. This aluminum-based epoxy mold, serving as the positive master mold for embossing, is casted over etched arrays of pyramidal pits in a silicon wafer. Methods of surface treatment of the wafer prior to casting and PDMS casting of the epoxy are discussed to preserve the silicon wafer for future use. Changes in the thickness of polyethylene are observed for varying embossing temperatures. The methodology described herein can quickly fabricate 20 disposable, single use chips in less than 30 min with the ability to scale up 4 times by using multiple molds simultaneously. When coupled as a platform supporting porous bead sensors, as in the recently developed Programmable Bio-Nano-Chip, this bead chip system can achieve limits of detection, for the cardiac biomarker C-reactive protein, of 0.3 ng/mL, thereby demonstrating that the approach is compatible with high performance, real-world clinical measurements in the context of point-of-care testing.


Subject(s)
Microarray Analysis , Microfluidic Analytical Techniques/instrumentation , Nanoparticles/chemistry , Polyethylene/chemistry , Hot Temperature , Humans , Microarray Analysis/instrumentation , Microarray Analysis/methods , Microscopy, Electron, Scanning , Polymers/chemistry , Silicon/chemistry
7.
Sensors (Basel) ; 12(11): 15467-99, 2012 Nov 09.
Article in English | MEDLINE | ID: mdl-23202219

ABSTRACT

Advances in lab-on-a-chip systems have strong potential for multiplexed detection of a wide range of analytes with reduced sample and reagent volume; lower costs and shorter analysis times. The completion of high-fidelity multiplexed and multiclass assays remains a challenge for the medical microdevice field; as it struggles to achieve and expand upon at the point-of-care the quality of results that are achieved now routinely in remote laboratory settings. This review article serves to explore for the first time the key intersection of multiplexed bead-based detection systems with integrated microfluidic structures alongside porous capture elements together with biomarker validation studies. These strategically important elements are evaluated here in the context of platform generation as suitable for near-patient testing. Essential issues related to the scalability of these modular sensor ensembles are explored as are attempts to move such multiplexed and multiclass platforms into large-scale clinical trials. Recent efforts in these bead sensors have shown advantages over planar microarrays in terms of their capacity to generate multiplexed test results with shorter analysis times. Through high surface-to-volume ratios and encoding capabilities; porous bead-based ensembles; when combined with microfluidic elements; allow for high-throughput testing for enzymatic assays; general chemistries; protein; antibody and oligonucleotide applications.


Subject(s)
Biosensing Techniques , Delivery of Health Care , Diagnosis , Lab-On-A-Chip Devices , Biomarkers/analysis , Humans , Microfluidics , Microscopy, Electron, Scanning , Point-of-Care Systems
8.
Lab Chip ; 12(24): 5249-56, 2012 Dec 21.
Article in English | MEDLINE | ID: mdl-23117481

ABSTRACT

Sample delivery is a crucial aspect of point-of-care applications where sample volumes need to be low and assay times short, while providing high analytical and clinical sensitivity. In this paper, we explore the influence of the factors surrounding sample delivery on analyte capture in an immunoassay-based sensor array manifold of porous beads resting in individual wells. We model using computational fluid dynamics and a flow-through device containing beads sensitized specifically to C-reactive protein (CRP) to explore the effects of volume of sample, rate of sample delivery, and use of recirculation vs. unilateral delivery on the effectiveness of the capture of CRP on and within the porous bead sensor. Rate of sample delivery lends to the development of a time-dependent, shrinking depletion region around the bead exterior. Our findings reveal that at significantly high rates of delivery, unique to porous bead substrates, capture at the rim of the bead is reaction-limited, while capture in the interior of the bead is transport-limited. While the fluorescence signal results from the aggregate of captured material throughout the bead, multiple kinetic regimes exist within the bead. Further, under constant pressure conditions dictated by the array architecture, we reveal the existence of an optimal flow rate that generates the highest signal, under point-of-care constraints of limited-volume and limited-time. When high sensitivity is needed, recirculation can be implemented to overcome the analyte capture limitations due to volume and time constraints. Computational simulations agree with experimental results performed under similar conditions.


Subject(s)
Biosensing Techniques/methods , Immunoassay/methods , Microspheres , Point-of-Care Systems , Models, Theoretical , Porosity , Reproducibility of Results
9.
Cancer Prev Res (Phila) ; 5(5): 706-16, 2012 May.
Article in English | MEDLINE | ID: mdl-22490510

ABSTRACT

Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive, and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, and modular (programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multimodal and multimarker screening approaches. In the p-BNCs, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing, and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a three-dimensional microfluidic environment, the p-BNC operating variables (incubation times, flow rates, and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (inter- and intra-assay precision of 1.2% and 1.9% and limit of detection of 1.0 U/mL) was achieved on this minisensor ensemble. Furthermore, validation with sera of patients with ovarian cancer (n = 20) showed excellent correlation (R(2) = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise, and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics.


Subject(s)
CA-125 Antigen/analysis , Carcinoma/diagnosis , Lab-On-A-Chip Devices , Microchip Analytical Procedures/methods , Ovarian Neoplasms/diagnosis , Blood Chemical Analysis/instrumentation , Blood Chemical Analysis/methods , Blood Chemical Analysis/standards , CA-125 Antigen/blood , Calibration , Carcinoma/blood , Computers/standards , Early Detection of Cancer/instrumentation , Early Detection of Cancer/methods , Early Detection of Cancer/standards , Early Detection of Cancer/trends , Enzyme-Linked Immunosorbent Assay/instrumentation , Enzyme-Linked Immunosorbent Assay/methods , Enzyme-Linked Immunosorbent Assay/standards , Female , Humans , Lab-On-A-Chip Devices/standards , Microchip Analytical Procedures/standards , Models, Biological , Osmolar Concentration , Ovarian Neoplasms/blood , Point-of-Care Systems/trends
10.
Anal Chem ; 84(5): 2569-75, 2012 Mar 06.
Article in English | MEDLINE | ID: mdl-22250703

ABSTRACT

Porous agarose microbeads, with high surface to volume ratios and high binding densities, are attracting attention as highly sensitive, affordable sensor elements for a variety of high performance bioassays. While such polymer microspheres have been extensively studied and reported on previously and are now moving into real-world clinical practice, very little work has been completed to date to model the convection, diffusion, and binding kinetics of soluble reagents captured within such fibrous networks. Here, we report the development of a three-dimensional computational model and provide the initial evidence for its agreement with experimental outcomes derived from the capture and detection of representative protein and genetic biomolecules in 290 µm porous beads. We compare this model to antibody-mediated capture of C-reactive protein and bovine serum albumin, along with hybridization of oligonucleotide sequences to DNA probes. These results suggest that, due to the porous interior of the agarose bead, internal analyte transport is both diffusion and convection based, and regardless of the nature of analyte, the bead interiors reveal an interesting trickle of convection-driven internal flow. On the basis of this model, the internal to external flow rate ratio is found to be in the range of 1:170 to 1:3100 for beads with agarose concentration ranging from 0.5% to 8% for the sensor ensembles here studied. Further, both model and experimental evidence suggest that binding kinetics strongly affect analyte distribution of captured reagents within the beads. These findings reveal that high association constants create a steep moving boundary in which unbound analytes are held back at the periphery of the bead sensor. Low association constants create a more shallow moving boundary in which unbound analytes diffuse further into the bead before binding. These models agree with experimental evidence and thus serve as a new tool set for the study of bioagent transport processes within a new class of medical microdevices.


Subject(s)
Microspheres , Models, Theoretical , Animals , C-Reactive Protein/metabolism , Cattle , Diffusion , Kinetics , Porosity , Protein Binding , Sepharose/chemistry , Serum Albumin, Bovine/metabolism
12.
Biosens Bioelectron ; 28(1): 251-6, 2011 Oct 15.
Article in English | MEDLINE | ID: mdl-21852104

ABSTRACT

This article reports on the fabrication of a disposable bio-nano-chip (BNC), a microfluidic device composed of polydimethylsiloxane (PDMS) and thiolene-based optical epoxy which is both cost-effective and suitable for high performance immunoassays. A novel room temperature (RT) bonding technique was utilized so as to achieve irreversible covalent bonding between PDMS and thiolene-based epoxy layers, while at the same time being compatible with the insertion of agarose bead sensors, selectively arranged in an array of pyramidal microcavities replicated in the thiolene thin film layer. In the sealed device, the bead-supporting epoxy film is sandwiched between two PDMS layers comprising of fluidic injection and drain channels. The agarose bead sensors used in the device are sensitized with anti-C-reactive protein (CRP) antibody, and a fluorescent sandwich-type immunoassay was run to characterize the performance of this device. Computational fluid dynamics (CFD) was used based on the device specifications to model the bead penetration. Experimental data revealed analyte penetration of the immunocomplex to 100 µm into the 280 µm diameter agarose beads, which correlated well with the simulation. A dose-response curve was obtained and the linear dynamic range of the assay was established over 1 ng/mL to 50 ng/mL with a limit of detection less than 1 ng/mL.


Subject(s)
C-Reactive Protein/analysis , Disposable Equipment , Immunoassay/instrumentation , Microfluidic Analytical Techniques , Dose-Response Relationship, Immunologic , Sepharose/chemistry
13.
SPIE Newsroom ; 2011 Mar 28.
Article in English | MEDLINE | ID: mdl-21818462

ABSTRACT

A diagnostic cytology-on-a-chip technique rapidly detects pre-malignant and malignant cells with high sensitivity and specificity.

14.
Small ; 7(5): 613-24, 2011 Mar 07.
Article in English | MEDLINE | ID: mdl-21290601

ABSTRACT

The slow development of cost-effective medical microdevices with strong analytical performance characteristics is due to a lack of selective and efficient analyte capture and signaling. The recently developed programmable bio-nano-chip (PBNC) is a flexible detection device with analytical behavior rivaling established macroscopic methods. The PBNC system employs ≈300 µm-diameter bead sensors composed of agarose "nanonets" that populate a microelectromechanical support structure with integrated microfluidic elements. The beads are an efficient and selective protein-capture medium suitable for the analysis of complex fluid samples. Microscopy and computational studies probe the 3D interior of the beads. The relative contributions that the capture and detection of moieties, analyte size, and bead porosity make to signal distribution and intensity are reported. Agarose pore sizes ranging from 45 to 620 nm are examined and those near 140 nm provide optimal transport characteristics for rapid (<15 min) tests. The system exhibits efficient (99.5%) detection of bead-bound analyte along with low (≈2%) nonspecific immobilization of the detection probe for carcinoembryonic antigen assay. Furthermore, the role analyte dimensions play in signal distribution is explored, and enhanced methods for assay building that consider the unique features of biomarker size are offered.


Subject(s)
Biomarkers/analysis , Lab-On-A-Chip Devices , Indicators and Reagents/chemistry , Microspheres , Sepharose/chemistry
15.
Tex Dent J ; 127(7): 651-61, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20737986

ABSTRACT

Saliva can be easily obtained in medical and non-medical settings, and contains numerous bio-molecules, including those typically found in serum for disease detection and monitoring. In the past two decades, the achievements of high-throughput approaches afforded by biotechnology and nanotechnology allow for disease-specific salivary biomarker discovery and establishment of rapid, multiplex, and miniaturized analytical assays. These developments have dramatically advanced saliva-based diagnostics. In this review, we discuss the current consensus on development of saliva/oral fluid-based diagnostics and provide a summary of recent research advancements of the Texas-Kentucky Saliva Diagnostics Consortium. In the foreseeable future, current research on saliva based diagnostic methods could revolutionize health care.


Subject(s)
Saliva/chemistry , Biomarkers/analysis , Diagnostic Techniques and Procedures , Humans , Lab-On-A-Chip Devices , Saliva/cytology , Saliva/physiology
16.
Biomark Med ; 4(1): 171-89, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20387312

ABSTRACT

Salivary diagnostics is an emerging field that has progressed through several important developments in the past decade, including the publication of the human salivary proteome and the infusion of federal funds to integrate nanotechnologies and microfluidic engineering concepts into developing compact point-of-care devices for rapid analysis of this secretion. In this article, we discuss some of these developments and their relevance to the prognosis, diagnosis and management of periodontitis, as an oral target, and cardiovascular disease, as a systemic example for the potential of these biodiagnostics. Our findings suggest that several biomarkers are associated with distinct biological stages of these diseases and demonstrate promise as practical biomarkers in identifying and managing periodontal disease, and acute myocardial infarction. The majority of these studies have progressed through biomarker discovery, with the identified molecules requiring more robust clinical studies to enable substantive validation for disease diagnosis. It is predicted that with continued advances in this field the use of a combination of biomarkers in multiplex panels is likely to yield accurate screening tools for these diagnoses in the near future.


Subject(s)
Biomarkers/analysis , Saliva/chemistry , Bone Remodeling/physiology , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/metabolism , Connective Tissue/chemistry , Humans , Inflammation Mediators/analysis , Lab-On-A-Chip Devices , Periodontal Diseases/diagnosis , Periodontal Diseases/metabolism , Proteome
17.
Cancer Prev Res (Phila) ; 3(4): 518-28, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20332305

ABSTRACT

Oral cancer is a deadly and disfiguring disease that could greatly benefit from new diagnostic approaches enabling early detection. In this pilot study, we describe a nano-bio-chip (NBC) sensor technique for analysis of oral cancer biomarkers in exfoliative cytology specimens, targeting both biochemical and morphologic changes associated with early oral tumorigenesis. Here, oral lesions from 41 dental patients, along with normal epithelium from 11 healthy volunteers, were sampled using a noninvasive brush biopsy technique. Specimens were enriched, immunolabeled, and imaged in the NBC sensor according to previously established assays for the epidermal growth factor receptor (EGFR) biomarker and cytomorphometry. A total of 51 measurement parameters were extracted using custom image analysis macros, including EGFR labeling intensity, cell and nuclear size, and the nuclear-to-cytoplasmic ratio. Four key parameters were significantly elevated in both dysplastic and malignant lesions relative to healthy oral epithelium, including the nuclear area and diameter (P < 0.0001), the nuclear-to-cytoplasmic ratio (P < 0.0001), and EGFR biomarker expression (P < 0.03). Further examination using logistic regression and receiver operating characteristic curve analyses identified morphologic features as the best predictors of disease (area under the curve < or =0.93) individually, whereas a combination of all features further enhanced discrimination of oral cancer and precancerous conditions (area under the curve, 0.94) with high sensitivity and specificity. Further clinical trials are necessary to validate the regression model and evaluate other potential biomarkers, but this pilot study supports the NBC sensor technique as a promising new diagnostic tool for early detection of oral cancer, which could enhance patient care and survival.


Subject(s)
Cytodiagnosis/methods , Cytological Techniques , ErbB Receptors/biosynthesis , Mouth Neoplasms/diagnosis , Nanotechnology/methods , Adult , Aged , Area Under Curve , Biomarkers, Tumor/analysis , Cell Nucleus/pathology , Cytodiagnosis/instrumentation , Cytological Techniques/instrumentation , Cytoplasm/pathology , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Mouth Neoplasms/genetics , Mouth Neoplasms/metabolism , Nanotechnology/instrumentation , Pilot Projects , Precancerous Conditions/diagnosis , Precancerous Conditions/genetics , Precancerous Conditions/metabolism , ROC Curve , Sensitivity and Specificity
18.
Anal Chem ; 82(5): 1571-9, 2010 Mar 01.
Article in English | MEDLINE | ID: mdl-20128622

ABSTRACT

There have been many recent advances in the nano-bio-chip analysis methodology with implications for a number of high-morbidity diseases including HIV, cancer, and heart disease. (To listen to a podcast about this article, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html .).


Subject(s)
Biosensing Techniques , Nanotechnology , Humans , Microfluidics
19.
Biosens Bioelectron ; 24(12): 3622-9, 2009 Aug 15.
Article in English | MEDLINE | ID: mdl-19576756

ABSTRACT

The integration of semiconductor nanoparticle quantum dots (QDs) into a modular, microfluidic biosensor for the multiplexed quantitation of three important cancer markers, carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), and Her-2/Neu (C-erbB-2) was achieved. The functionality of the integrated sample processing, analyte capture and detection modalities was demonstrated using both serum and whole saliva specimens. Here, nano-bio-chips that employed a fluorescence transduction signal with QD-labeled detecting antibody were used in combination with antigen capture by a microporous agarose bead array supported within a microfluidics ensemble so as to complete the sandwich-type immunoassay. The utilization of QD probes in this miniaturized biosensor format resulted in signal amplification 30 times relative to that of standard molecular fluorophores as well as affording a reduction in observed limits of detection by nearly 2 orders of magnitude (0.02 ng/mL CEA; 0.11 pM CEA) relative to enzyme-linked immunosorbent assay (ELISA). Assay validation studies indicate that measurements by the nano-bio-chip system correlate to standard methods at R(2)=0.94 and R(2)=0.95 for saliva and serum, respectively. This integrated nano-bio-chip assay system, in tandem with next-generation fluorophores, promises to be a sensitive, multiplexed tool for important diagnostic and prognostic applications.


Subject(s)
Biomarkers, Tumor/analysis , Blood Chemical Analysis/instrumentation , Nanotechnology/instrumentation , Neoplasm Proteins/analysis , Neoplasms/metabolism , Protein Array Analysis/instrumentation , Saliva/chemistry , Biosensing Techniques/instrumentation , Equipment Design , Equipment Failure Analysis , Humans , Neoplasms/diagnosis , Quantum Dots , Spectrometry, Fluorescence/instrumentation , Staining and Labeling/methods
20.
Clin Chem ; 55(8): 1530-8, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19556448

ABSTRACT

BACKGROUND: For adults with chest pain, the electrocardiogram (ECG) and measures of serum biomarkers are used to screen and diagnose myocardial necrosis. These measurements require time that can delay therapy and affect prognosis. Our objective was to investigate the feasibility and utility of saliva as an alternative diagnostic fluid for identifying biomarkers of acute myocardial infarction (AMI). METHODS: We used Luminex and lab-on-a-chip methods to assay 21 proteins in serum and unstimulated whole saliva procured from 41 AMI patients within 48 h of chest pain onset and from 43 apparently healthy controls. Data were analyzed by use of logistic regression and area under curve (AUC) for ROC analysis to evaluate the diagnostic utility of each biomarker, or combinations of biomarkers, in screening for AMI. RESULTS: Both established and novel cardiac biomarkers demonstrated significant differences in concentrations between patients with AMI and controls without AMI. The saliva-based biomarker panel of C-reactive protein, myoglobin, and myeloperoxidase exhibited significant diagnostic capability (AUC = 0.85, P < 0.0001) and in conjunction with ECG yielded strong screening capacity for AMI (AUC = 0.96) comparable to that of the panel (brain natriuretic peptide, troponin-I, creatine kinase-MB, myoglobin; AUC = 0.98) and far exceeded the screening capacity of ECG alone (AUC approximately 0.6). En route to translating these findings to clinical practice, we adapted these unstimulated whole saliva tests to a novel lab-on-a-chip platform for proof-of-principle screens for AMI. CONCLUSIONS: Complementary to ECG, saliva-based tests within lab-on-a-chip systems may provide a convenient and rapid screening method for cardiac events in prehospital stages for AMI patients.


Subject(s)
Biomarkers/analysis , Myocardial Infarction/diagnosis , Protein Array Analysis/methods , Proteins/analysis , Saliva/chemistry , Acute Disease , Adult , Aged , Aged, 80 and over , Blood Proteins/analysis , Female , Humans , Male , Middle Aged , Point-of-Care Systems , ROC Curve , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...