Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Children (Basel) ; 8(6)2021 May 25.
Article in English | MEDLINE | ID: mdl-34070245

ABSTRACT

For patients too young to be fitted with an expandable prosthesis, limb salvage surgery requires other strategies. The main problems are related to the impossibility of implanting an expandable prosthesis to the residual bone growth that is much too big in relation to the bone size, with the precocious implant loosening and/or the residual absence of bone growth, as well as the problem of limb length and shape difference. In this paper, we report a possible reconstruction solution using a composite prosthesis for an Ewing's sarcoma of the proximal femur in an infant patient. After resection, a femoral stem was cemented into the distal third of a homoplastic humerus; a carbon fiber plate was used to stabilize the bone/homograft interface. At the one-year follow-up, the patient was free of disease and able to walk with only a slight limp. This case report describes a possible solution for very small patients. An adult humerus is of the right size to replace a child's lower limb segments, and the distal humerus can be shaped, maintaining a cortex stiff enough to support a prosthesis. Very young patients might obtain a faster osteointegration of the graft than adults, due to their higher biological activity and, in this case, the diapasonal shape of the allograft might also have contributed to accelerated fusion. Moreover, the use of a graft to fit the prosthesis avoids loosening issues due to canal widening, hypothetically providing more growing time before system failure and revision surgery. However, although this technique is promising, further studies are necessary to confirm our findings and to verify if this procedure allows easier future prosthesis implantation.

3.
Injury ; 51 Suppl 3: S28-S33, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32723529

ABSTRACT

INTRODUCTION: Screw fixation of pelvic ring fractures is a common, but demanding procedure and navigation techniques were introduced to increase the precision of screw placement. The purpose of this case series is to demonstrate a lower screw malposition rate using percutaneous fixation of pelvic ring fractures and sacroiliac dislocations guided by navigation system based on 3D-fluoroscopic images compared to traditional imaging techniques and to evaluate the functional outcomes of this innovative procedure. PATIENT AND METHODS: 10 cases of disrupted pelvic ring lesions treated in our hospital from February 2018 to December 2018 were included for closed reduction and percutaneous screw fixation of using with O-Arm and the acquisition by the Navigator. Preoperative assessment was performed on the patients by means of X Ray imaging and CT scan. Routine CT was carried out on third postoperative day to evaluate screw placement. Measures of radiation exposure were extracted directly from reports provided by system. Quality of life was evaluated by SF 36-questionnaire 6 months after surgery. RESULTS: 12 iliosacral- and 2 ramus pubic-screws were inserted. In post-operative CT-scans the screw position was assessed and graded using the score described by Smith. No wound infection or iatrogenic neurovascular damage were observed. No re-operations were performed. The exposure to radiation is, for the patient, slightly greater than that resulting from the use of traditional fluoroscopic systems, while it is naught for the surgical team, which at the time of image acquisition is located outside the room. DISCUSSION AND CONCLUSION: The execution of an intraoperative 3D-fluoroscopic scan can on its own suffice as a post-operative control examination since its accuracy is similar to that of the post-operative CT. The use of a navigated 3d fluoroscopy exposes the patient to an amount of radiation slightly greater than that of traditional fluoroscopy, but the dose is lower than a CT examination. For the operating team, exposure to radiation is naught. 3D-fluoroscopic navigation is a safe tool providing high accuracy of percutaneous screw placement for pelvic ring fractures. Finally, despite the small cohort of patients studied, the excellent results obtained regarding the patients' quality of life and the absence of complications allow us to look positively at the future of this technique, which needs further studies and improvement.


Subject(s)
Fractures, Bone , Pelvic Bones , Surgery, Computer-Assisted , Bone Screws , Fluoroscopy , Fracture Fixation, Internal , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Imaging, Three-Dimensional , Pelvic Bones/diagnostic imaging , Pelvic Bones/surgery , Pilot Projects , Quality of Life , Tomography, X-Ray Computed
4.
World J Orthop ; 10(2): 63-70, 2019 Feb 18.
Article in English | MEDLINE | ID: mdl-30788223

ABSTRACT

Total knee arthroplasty is a common procedure, with extremely good clinical results. Despite this success, it produces 20% unsatisfactory results. Among the causes of these failures is metal hypersensitivity. Metal sensitization is higher in patients with a knee arthroplasty than in the general population and is even higher in patients undergoing revision surgery. However, a clear correlation between metal sensitization and symptomatic knee after surgery has not been ascertained. Surely, patients with a clear history of metal allergy must be carefully examined through dermatological and laboratory testing before surgery. There is no globally accepted diagnostic algorithm or laboratory test to diagnose metal hypersensitivity or metal reactions. The patch test is the most common test to determine metal hypersensitivity, though presenting some limitations. Several laboratory assays have been developed, with a higher sensitivity compared to patch testing, yet their clinical availability is not widespread, due to high costs and technical complexity. Symptoms of a reaction to metal implants present across a wide spectrum, ranging from pain and cutaneous dermatitis to aseptic loosening of the arthroplasty. However, although cutaneous and systemic hypersensitivity reactions to metals have arisen, thereby increasing concern after joint arthroplasties, allergies against implant materials remain quite rare and not a well-known problem. The aim of the following paper is to provide an overview on diagnosis and management of metal hypersensitivity in patients who undergo a total knee arthroplasty in order clarify its real importance.

5.
Int Orthop ; 43(1): 177-185, 2019 01.
Article in English | MEDLINE | ID: mdl-30225589

ABSTRACT

PURPOSE: The sacrum is a mechanical nucleus working as the base for the spinal column, as well as the keystone of the pelvic ring. Thus, injuries of the sacrum can lead to biomechanical instability and nerve conduction abnormality. METHODS: The common classification is the Denis classification, but these fractures are often part of a lesion of the posterior pelvic ring and therefore the Tile classification is very useful. The goals of operative intervention are to reduce fracture fragments, protect neurological structures, and provide adequate stability for early mobilization. RESULTS: The stabilization of these injuries can be difficult even in a patient with adequate bone stock and concomitant medical comorbidities. The posterior-ring tension-band metallic plate and sacroiliac joint screw are two commonly used methods for posterior internal fixation of the pelvis. CONCLUSIONS: In this study, we evaluate the differences, in the treatment of sacral fractures, between the two techniques, revising the literature and our experience.


Subject(s)
Fracture Fixation, Internal/methods , Sacrum/surgery , Spinal Fractures/surgery , Adolescent , Adult , Aged , Bone Plates , Bone Screws , Child , Female , Fracture Fixation, Internal/instrumentation , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures , Retrospective Studies , Sacrum/injuries , Young Adult
6.
Joints ; 5(3): 184-187, 2017 Sep.
Article in English | MEDLINE | ID: mdl-29270551

ABSTRACT

Pigmented villonodular synovitis (PVNS) is a rare, benign, proliferative neoplastic condition affecting synovial-lined anatomic spaces. PVNS is characterized by hypertrophy of a synovial membrane by villous, nodular, and villonodular proliferation, with pigmentation secondary to hemosiderin deposition. The two forms of PVNS that have been described are diffuse (DPVNS) and localized (LPVNS). The knee is the most commonly involved anatomic location, followed by hip, ankle, shoulder, and elbow. Diagnosis of PVNS is not always obvious clinically. Various imaging modalities are often necessary to exclude other conditions and narrow the diagnosis. Magnetic resonance imaging has become the modality of choice for diagnosing PVNS. We present a case of intra-articular LPVNS with an extra-articular extension through the posterior capsule that has been successfully removed in an all-arthroscopic fashion.

7.
Int J Surg Case Rep ; 30: 9-12, 2017.
Article in English | MEDLINE | ID: mdl-27898357

ABSTRACT

INTRODUCTION: Metallosis is a condition characterized by an infiltration of periprosthetic soft tissues and bone by metallic debris resulting from wear or failure of joint arthroplasties. PRESENTATION OF CASE: Authors describe a case of a 45-year-old man treated for an osteosarcoma of the distal femur with a modular prosthesis when he was 18 years old, he developed massive metallosis with skin dyspigmentation after 17 years. His medical\surgical history was remarkable for a left tumoral knee prosthesis implanted 21 years ago. Two years before revision, the patient had a car accident with a two-points prosthesis breakage and despite the surgeon's advice, the patient refused surgery. In two years, prosthesis malfunction caused a progressive catastrophic soft tissues infiltration of metallic debris. DISCUSSION AND CONCLUSION: Authors suggest that if prosthesis fracture is detected, revision surgery should be attempted as earlier as possible.