1.
J Radiol Prot ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38885627

ABSTRACT

Exposure to the radon gas within a building can result in an increased risk of lung cancer. To minimise the health risk, indoor radon concentrations can be reduced using well-established mitigation methods. The performance of various radon reduction methods, their combination as well as other factors that can impact the efficiency of radon mitigation, were analysed using data collected from approximately 2,800 dwellings that had installed radon mitigation techniques during the period 2007 to 2017. As demonstrated previously (Hodgson 2011), active methods are the most effective at reducing high concentrations of radon to below the Action and Target Levels (200 Bq m-3 and 100 Bq m-3 respectively). Reduction factors of up to 5.5 using single active methods and 8.3 using a combination of active methods were estimated in this study. For indoor radon levels greater than 1,000 Bq m-3, the Active Sump remained the most efficient technique, with the Active Underfloor Ventilation being the second most effective method. Passive methods alone or in combination with other passive methods offered moderate reductions at high radon concentration. Of the passive methods, Underfloor Ventilation was found to have the highest performance with a reduction factor of 1.8. The conclusions of this study should be used to update guidance for stakeholders including householders, contractors, radon awareness campaigns and the UKradon.org website.