Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Cardiol ; 98(3): 431-7, 2005 Feb 28.
Article in English | MEDLINE | ID: mdl-15708176

ABSTRACT

BACKGROUND: Determination of ST-segment deviation (STdev) and its resolution (STR) by reperfusion strategies have become important tools in the assessment of patients with acute myocardial infarction (AMI). STdev has been measured at different time-points, i.e. at 20-80 ms after the J-point. There are no data comparing STR at different time-points. METHODS AND RESULTS: STdev was measured using a new computer-assisted workflow. The intraclass correlation coefficients (ICC) for validity and agreement vs. classical manual measurements (n=1020) were both 0.996 (p<0.0001). The reliability indices were 0.991 (95% CI 0.990-0.992) for the manual vs. 0.995 (95% CI 0.995-0.996) for the computer-assisted method, indicating superiority of the latter. 12-lead STdev were determined on ECGs before (baseline) and 180 min after start of thrombolytic therapy, measured both at the J-point (STdev(J)) and 20 ms after the J-point (STdev(J20); n=2400). STdev(J20) was on average 0.01+/-0.03 mV higher than STdev(J) (p<0.0001) with a tendency towards larger differences for higher ST-elevations (p<0.001). Although the average STR calculated from STdev(J20) and STdev(J) was not statistically different in any infarct location group, in 26% of the patients the difference was >10%, and 11% of the patients were classified into another ST-resolution group. Analysing STdev only in the single lead with the highest ST-elevation at baseline (a simplified measurement which may eliminate the confounding effect of ST-depressions) showed an even higher classification discordance (14% of the patients). CONCLUSIONS: The time-point of STdev measurement is an important variable to be accounted for when evaluating ST resolution data. Uncontrolled extrapolation of classification schemes based on STdev(J20) to other time-points cannot be justified.


Subject(s)
Heart Conduction System/physiopathology , Myocardial Infarction/physiopathology , Electrocardiography , Humans , Myocardial Infarction/therapy , Myocardial Reperfusion
2.
J Electrocardiol ; 36(3): 187-93, 2003 Jul.
Article in English | MEDLINE | ID: mdl-12942480

ABSTRACT

Quantitative analysis of ST-segment deviations (STdev) and their resolution by treatment (STR; calculated from a combined sum of STdev in multiple leads) are used in trials on reperfusion for myocardial infarction (MI). Unreadable or unavailable electrocardiogram (ECG) leads are a common reason for exclusion, decreasing the statistical power of the trials. We developed mathematical formulas for reconstruction of immeasurable STdev based on STdev from other available leads on the 12-lead ECG. Formulas were deducted from a database of computer-assisted STdev measurements in 2 ECGs (baseline and 180 min after thrombolysis) of 1121 pts. Their accuracy was later evaluated on a second dataset of 377 pts. Acceptable fits could be derived for absent single leads, or for groups of absent limb leads (I-II-III or aVL-aVF). The intraclass correlation coefficient between real and calculated STdev was >or= 0.80 for each (0.77 for V1 in inferior MI). The correlations between STR calculated from original data and from reconstructed STdev were very strong (all intraclass correlation >or=0.97), and discordance in STR subgroup categorization occurred in

Subject(s)
Electrocardiography , Myocardial Infarction/diagnosis , Humans , Models, Cardiovascular , Models, Theoretical , Regression Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...