Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 91
Filter
1.
Aust Vet J ; 101(1-2): 65-77, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36358003

ABSTRACT

INTRODUCTION: This cadaveric study describes the collateral ligament constraints on the feline tarsocrural joint using stress radiography. METHODS: Thirty-six feline cadaveric hindlimbs free of orthopaedic disease were placed in a custom-made jig and controlled stress radiography was performed before and after transection of one, or both collateral ligaments. Changes in varus and valgus deviation and pronation and supination were measured at three limb angles (extension, 120o flexion and 90o flexion). RESULTS: There was a significant positive percentage change in the mean angle of varus deviation after transection of the fibulocalcaneal ligament at all limb positions (extension: 41%, 120°: 78%, 90°: 63%). There was a significant positive percentage change in the mean angle of varus deviation after transection of the fibulotalar ligament at extension (14%). There was a significant positive percentage change in the mean angle of varus deviation after transection of both fibulocalcaneal and fibulotalar ligaments at all limb positions (extension: 58%, 120°: 67%, 90°: 67%), and in the mean angle of valgus deviation (100%) and supination (89%) at 90 degrees flexion. There was a significant positive percentage change in the mean angle of valgus deviation after transection of the tibiocentral ligament at all limb positions (extension: mean 79%, 120°: 43%, 90°: 49%) and the mean angle of pronation at 120 degrees flexion (10%). There was a significant positive percentage change in the mean angle of varus deviation after transection of the tibiotalar ligament at extension (11%) and at 90 degrees flexion (54%) and in the mean angle of pronation at all limb positions (extension: 11%, 120°: 19%, 90°: 32%). There was a significant positive percentage change in the mean angle of valgus deviation (extension: 255%, 120°: 172%, 90°: 176%) and pronation (extension: 58%, 120°: 134%, 90°: 76%) after transection of the tibiocentral and tibiotalar ligaments at all limb positions and in the mean angle of varus deviation at extension (13%) and 90 degrees flexion (69%). CONCLUSION: The medial collateral ligaments prevent against excessive valgus deviation and pronation, and the lateral collateral ligaments prevent against excessive varus deviation and supination. At 90 degrees flexion subluxation of the talus occurs on the ipsilateral side of the ligament injury resulting in an additional direction of instability.


Subject(s)
Cat Diseases , Collateral Ligaments , Elbow Injuries , Joint Instability , Cats , Animals , Joint Instability/veterinary , Biomechanical Phenomena , Cadaver , Collateral Ligaments/diagnostic imaging , Collateral Ligaments/injuries , Elbow Injuries/veterinary
2.
Magn Reson Imaging ; 85: 168-176, 2022 01.
Article in English | MEDLINE | ID: mdl-34666159

ABSTRACT

A recently developed compact 3 T (C3T) MRI scanner with high performance gradients [1, 2] has a dedicated radiofrequency (RF) transmit coil that exposes only the head, neck and a small portion of the upper body region during head-first scanning. Due to the unique coil geometry and patient positioning, the established SAR model used for a conventional whole-body scanner cannot be directly translated to the C3T. Here a specific absorption rate (SAR) estimation and validation framework was developed and used to implement a dedicated and accurate SAR prediction model for the C3T. Two different SAR prediction models for the C3T were defined and evaluated: one based on an anatomically derived exposed mass, and one using a fixed anatomical position located caudally to the RF coil to determine the exposed mass. After coil modeling and virtual human body simulation, the designed SAR prediction model was implemented on the C3T and verified with calorimetry and in vivo scan power monitoring. The fixed-demarcation exposed mass model was selected as appropriate exposed mass region to accurately estimate the SAR deposition in the patient on the C3T.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Computer Simulation , Humans , Patient Positioning , Phantoms, Imaging
3.
AJNR Am J Neuroradiol ; 40(2): 217-223, 2019 02.
Article in English | MEDLINE | ID: mdl-30606726

ABSTRACT

BACKGROUND AND PURPOSE: MR imaging rescans and recalls can create large hospital revenue loss. The purpose of this study was to develop a fast, automated method for assessing rescan need in motion-corrupted brain series. MATERIALS AND METHODS: A deep learning-based approach was developed, outputting a probability for a series to be clinically useful. Comparison of this per-series probability with a threshold, which can depend on scan indication and reading radiologist, determines whether a series needs to be rescanned. The deep learning classification performance was compared with that of 4 technologists and 5 radiologists in 49 test series with low and moderate motion artifacts. These series were assumed to be scanned for 2 scan indications: screening for multiple sclerosis and stroke. RESULTS: The image-quality rating was found to be scan indication- and reading radiologist-dependent. Of the 49 test datasets, technologists created a mean ratio of rescans/recalls of (4.7 ± 5.1)/(9.5 ± 6.8) for MS and (8.6 ± 7.7)/(1.6 ± 1.9) for stroke. With thresholds adapted for scan indication and reading radiologist, deep learning created a rescan/recall ratio of (7.3 ± 2.2)/(3.2 ± 2.5) for MS, and (3.6 ± 1.5)/(2.8 ± 1.6) for stroke. Due to the large variability in the technologists' assessments, it was only the decrease in the recall rate for MS, for which the deep learning algorithm was trained, that was statistically significant (P = .03). CONCLUSIONS: Fast, automated deep learning-based image-quality rating can decrease rescan and recall rates, while rendering them technologist-independent. It was estimated that decreasing rescans and recalls from the technologists' values to the values of deep learning could save hospitals $24,000/scanner/year.


Subject(s)
Artifacts , Brain/diagnostic imaging , Deep Learning , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Female , Humans , Male , Neuroimaging/methods
5.
Oncogene ; 36(29): 4161-4170, 2017 07 20.
Article in English | MEDLINE | ID: mdl-28319063

ABSTRACT

The major breast cancer suppressor proteins BRCA1 and BRCA2 play essential roles in homologous recombination (HR)-mediated DNA repair, which is thought to be critical for tumor suppression. The two BRCA proteins are linked by a third tumor suppressor, PALB2, in the HR pathway. While truncating mutations in these genes are generally pathogenic, interpretation of missense variants remains a challenge. To date, patient-derived missense variants that disrupt PALB2 binding have been identified in BRCA1 and BRCA2; however, there has not been sufficient evidence to prove their pathogenicity in humans, and no variants in PALB2 that disrupt either its BRCA1 or BRCA2 binding have been reported. Here we report on the identification of a novel PALB2 variant, c.104T>C (p.L35P), that segregates in a family with a strong history of breast cancer. Functional analyses showed that L35P abrogates the PALB2-BRCA1 interaction and completely disables its abilities to promote HR and confer resistance to platinum salts and PARP inhibitors. Whole-exome sequencing of a breast cancer from a c.104T>C carrier revealed a second, somatic, truncating mutation affecting PALB2, and the tumor displays hallmark genomic features of tumors with BRCA mutations and HR defects, cementing the pathogenicity of L35P. Parallel analyses of other germline variants in the PALB2 N-terminal BRCA1-binding domain identified multiple variants that affect HR function to varying degrees, suggesting their possible contribution to cancer development. Our findings establish L35P as the first pathogenic missense mutation in PALB2 and directly demonstrate the requirement of the PALB2-BRCA1 interaction for breast cancer suppression.


Subject(s)
BRCA1 Protein/metabolism , Breast Neoplasms/metabolism , Nuclear Proteins/metabolism , Tumor Suppressor Proteins/metabolism , Amino Acid Sequence , BRCA1 Protein/genetics , Breast Neoplasms/genetics , Breast Neoplasms/pathology , Cell Line, Tumor , Fanconi Anemia Complementation Group N Protein , Female , Genetic Predisposition to Disease , Humans , Mutation, Missense , Nuclear Proteins/genetics , Protein Binding , Risk , Transfection , Tumor Suppressor Proteins/genetics
6.
Magn Reson Imaging ; 33(3): 351-7, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25523607

ABSTRACT

As the number of coils increases in multi-channel MRI receiver-coil arrays, RF cables and connectors become increasingly bulky and heavy, degrading patient comfort and slowing workflow. Inductive coupling of signals provides an attractive "wireless" approach, with the potential to reduce coil weight and cost while simplifying patient setup. In this work, multi-channel inductively coupled anterior arrays were developed and characterized for 1.5T imaging. These comprised MR receiver coils inductively (or "wirelessly") linked to secondary or "sniffer" coils whose outputs were transmitted via preamps to the MR system cabinet. The induced currents in the imaging coils were blocked by passive diode circuits during RF transmit. The imaging arrays were totally passive, obviating the need to deliver power to the coils, and providing lightweight, untethered signal reception with easily positioned coils. Single-shot fast spin echo images were acquired from 5 volunteers using a 7-element inductively coupled coil array and a conventionally cabled 7-element coil array of identical geometry, with the inductively-coupled array showing a relative signal-to-noise ratio of 0.86 +/- 0.07. The concept was extended to a larger 9-element coil array to demonstrate the effect of coil element size on signal transfer and RF-transmit blocking.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Adult , Computer Simulation , Equipment Design , Healthy Volunteers , Humans , Image Processing, Computer-Assisted , Middle Aged , Phantoms, Imaging , Radio Waves , Signal Processing, Computer-Assisted , Signal-To-Noise Ratio , Wireless Technology
7.
Circulation ; 110(6): 732-7, 2004 Aug 10.
Article in English | MEDLINE | ID: mdl-15289374

ABSTRACT

BACKGROUND: MRI can identify patients with obstructive coronary artery disease by imaging the left ventricular myocardium during a first-pass contrast bolus in the presence and absence of pharmacologically induced myocardial hyperemia. The purpose of this multicenter dose-ranging study was to determine the minimally efficacious dose of gadopentetate dimeglumine injection (Magnevist Injection; Berlex Laboratories) for detecting obstructive coronary artery disease. METHOD AND RESULTS: A total of 99 patients scheduled for coronary artery catheterization as part of their clinical evaluation were enrolled in this study. Patients were randomized to 1 of 3 doses of gadopentate dimeglumine: 0.05, 0.10, or 0.15 mmol/kg. First-pass perfusion imaging was performed during hyperemia (induced by a 4-minute infusion of adenosine at a rate of 140 microg x kg(-1) x min(-1)) and then again in the absence of adenosine with otherwise identical imaging parameters and the same contrast dose. Perfusion defects were evaluated subjectively by 4 blinded reviewers. Receiver-operating curve analysis showed that the areas under the receiver-operating curve were 0.90, 0.72, and 0.83 for the low-, medium-, and high-contrast doses, respectively, compared with quantitative coronary angiography (diameter stenosis > or =70%). For the low-dose group, mean sensitivity was 93+/-0%, mean specificity was 75+/-7%, and mean accuracy was 85+/-3%. CONCLUSIONS: First-pass perfusion MRI is a safe and accurate test for identifying patients with obstructive coronary artery disease. A low dose of 0.05 mmol/kg gadopentetate dimeglumine is at least as efficacious as higher doses.


Subject(s)
Coronary Circulation , Coronary Disease/pathology , Magnetic Resonance Imaging/methods , Myocardium/pathology , Adenosine , Aged , Area Under Curve , Cardiac Catheterization , Contrast Media/administration & dosage , Coronary Angiography , Coronary Disease/diagnostic imaging , Dose-Response Relationship, Drug , False Positive Reactions , Female , Gadolinium DTPA/administration & dosage , Humans , Hyperemia/chemically induced , Male , Middle Aged , Prospective Studies , ROC Curve , Sensitivity and Specificity , Single-Blind Method
8.
Rhinology ; 41(3): 167-74, 2003 Sep.
Article in English | MEDLINE | ID: mdl-14579657

ABSTRACT

Topical decongestants are available over the counter and provide rapid relief of nasal obstruction for conditions of short duration, for example the common cold. Manufacturers' recommendations are that topical decongestants should not be used regularly for more than 1 week in view of the risk of rebound mucosal hyperaemia with persistent nasal obstruction and refractoriness to further effects of decongestants. For this reason we performed a randomised double-blind placebo-controlled trial in 30 normal adult subjects with 0.05% oxymetazoline nasal spray 2 sprays (0.1 ml/spray) to each nostril 3 times daily over an extended period of 4 weeks. Degree of nasal blockage was assessed before and after 4 weeks treatment and for 2 weeks following discontinuation of treatment. Outcome measures included diary symptom scores and measurements of nasal peak inspiratory flow, airway resistance (using posterior active rhinomanometry) and volume (using acoustic rhinometry). Nasal patency was assessed at baseline and 15 minutes after oxymetazoline challenge at each clinic visit. Results demonstrated no significant increases in subjective nasal blockage throughout the 6 weeks study period in either oxymetazoline- or placebo-treated subjects. No significant differences were observed between groups for baseline measurements of nasal peak inspiratory flow, airway resistance or volume at each clinic visit. A highly significant decongestant effect of oxymetazoline was observed at each clinic visit with changes in all 3 measurements for both treatment groups, again with no significant differences between groups. In summary, in normal subjects, we identified no significant nasal blockage or impaired decongestant response to oxymetazoline following 4 weeks treatment with oxymetazoline compared to matched placebo nasal spray.


Subject(s)
Nasal Decongestants/adverse effects , Nasal Obstruction/chemically induced , Nasal Obstruction/drug therapy , Oxymetazoline/adverse effects , Tachyphylaxis/physiology , Administration, Intranasal , Adolescent , Adult , Diagnostic Techniques, Respiratory System , Double-Blind Method , Female , Humans , Male , Middle Aged , Nasal Decongestants/administration & dosage , Oxymetazoline/administration & dosage , Treatment Outcome
9.
Top Magn Reson Imaging ; 12(4): 283-99, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11687715

ABSTRACT

Contrast-enhanced magnetic resonance angiography (CE MR angiography) has benefited from advancements in MR imaging speed, pulse sequence design, and dedicated equipment and algorithms for its performance. These improvements have greatly expanded the number of options available to the operator and enabled the application of CE MR angiography to a broader range of clinical applications. In this article, the various timing options, pulse sequence innovations, and contrast administration concerns related to clinical CE MR angiography are reviewed. Pertinent issues related to multiphase and multistation bolus chase CE MR angiography also will be discussed.


Subject(s)
Contrast Media , Gadolinium , Image Enhancement/methods , Magnetic Resonance Angiography/methods , Humans
10.
J Magn Reson Imaging ; 14(4): 368-73, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11599060

ABSTRACT

A new method was investigated for improving the efficiency of ECG-gated coronary magnetic resonance angiography (CMRA) by accurate, automated tracking of the vessel motion over the cardiac cycle. Vessel tracking was implemented on a spiral gradient-echo pulse sequence with sub-millimeter in-plane spatial resolution as well as high image signal to noise ratio. Breath hold 2D CMRA was performed in 18 healthy adult subjects (mean age 46 +/- 14 years). Imaging efficiency, defined as the percentage of the slices where more than 30 mm of the vessel is visualized, was computed in multi-slice spiral scans with and without vessel tracking. There was a significant improvement in the efficiency of the vessel tracking sequence compared to the multi-slice sequence (56% vs. 32%, P < 0.001). The imaging efficiency increased further when the true motion of the coronary arteries (determined using a cross correlation algorithm) was used for vessel tracking as opposed to a linear model for motion (71% vs. 57%, P < 0.05). The motion of the coronary arteries was generally found to be linear during the systolic phase and nonlinear during the diastolic phase. The use of subject-tailored, automated tracking of vessel positions resulted in improved efficiency of coronary artery illustration on breath held 2D CMRA.


Subject(s)
Coronary Angiography/methods , Magnetic Resonance Angiography/methods , Coronary Vessels/physiology , Female , Humans , Male , Middle Aged
11.
Int J Cardiovasc Imaging ; 17(4): 287-94; discussion 295-6, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11599868

ABSTRACT

A comparison between the prospective and retrospective respiratory navigator gating in MR coronary angiography was performed with eight normal subjects. A three-dimensional (3D) ECG-gated fast gradient echo pulse sequence was used for image data acquisition. The results show that the MR coronary angiography obtained using retrospective gating retains a considerable amount of motion artifacts. In this study, the images acquired using prospective navigator gating demonstrated significantly reduced motion artifacts (p = 0.009), improved vessel visibility (p = 0.021) with reduced imaging time (p = 0.013) compared to the images obtained using retrospective navigator gating.


Subject(s)
Coronary Angiography , Magnetic Resonance Angiography/methods , Motion , Respiratory Muscles/diagnostic imaging , Respiratory Muscles/physiology , Adult , Arteries/ultrastructure , Artifacts , Coronary Vessels/ultrastructure , Humans , Male , Prospective Studies , Radiographic Image Enhancement , Reference Values , Retrospective Studies
12.
J Magn Reson Imaging ; 13(5): 682-9, 2001 May.
Article in English | MEDLINE | ID: mdl-11329189

ABSTRACT

The purposes of our study were to investigate the benefits of using a single dose of an extracellular contrast agent for coronary magnetic resonance angiography (CMRA) and to determine the relative benefits of arterial-phase vs. delayed-phase image acquisition. The right coronary artery was imaged in 10 healthy adults using a breath-hold, two-dimensional fast gradient echo pulse sequence designed for vessel tracking (multiphase, multislice image acquisition). Pre- and postcontrast CMRA was performed. Postcontrast imaging consisted of arterial- and delayed-phase CMRA following a 15 mL bolus (single dose) of contrast media and of delayed-phase imaging following a cumulative 45 mL contrast dose (triple dose). Contrast-enhanced CMRA provided a significantly higher (P < 0.001) signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than noncontrast CMRA. CNR was highest for single-dose arterial-phase CMRA (13.1 +/- 4.5) and triple-dose delayed-phase CMRA (13.0 +/- 4.8), followed by single-dose delayed-phase CMRA (8.4 +/- 3.5) and noncontrast CMRA (4.2 +/- 1.8). Single-dose arterial-phase CMRA provided the best visualization of the distal right coronary artery and was preferred for blinded physician assessments. We concluded that utilization of a single dose of extracellular contrast media improves CMRA, especially if timed for arterial-phase imaging. J. Magn. Reson. Imaging 2001;13:682-689.


Subject(s)
Contrast Media/administration & dosage , Coronary Angiography , Coronary Vessels/pathology , Gadolinium DTPA , Image Enhancement , Image Processing, Computer-Assisted , Magnetic Resonance Angiography , Adult , Dose-Response Relationship, Drug , Female , Humans , Infusions, Intravenous , Male , Middle Aged , Reference Values
13.
J Magn Reson Imaging ; 13(5): 714-21, 2001 May.
Article in English | MEDLINE | ID: mdl-11329192

ABSTRACT

PURPOSE: To investigate the feasibility of preferential arterial imaging using gadolinium-enhanced thick-slice phase-contrast imaging. METHODS: Six healthy volunteers were studied using a peripheral-gated segmented k-space CINE phase-contrast pulse sequence using four views per RR interval with flow encoding in the superior-inferior direction. Images at the level of the popiteal trifurcation were acquired postcontrast with different section thicknesses (4-8 cm) and VENC values (20-150 cm/sec), and phase-difference processing. RESULTS: The post-gadolinium contrast-enhanced thick-slice phase-contrast acquisitions demonstrated the ability to visualize the tibio-peroneal (trifurcation) arteries, especially in systole. With MR contrast agents, the signal from blood is raised significantly above that of stationary tissue from T(1) shortening such that the partial volume artifact is reduced in thick-slice acquisitions. Furthermore, by selecting the VENC value as a function of the cardiac cycle, the noise floor can be raised to selectively suppress flow values less than that of the noise threshold, allowing better accentuation of arterial structures at systole. CONCLUSIONS: Thick-slice phase-contrast acquisition with phase-difference processing has been observed to reduce partial volume artifacts when an MR contrast agent substantially increases signal in the vasculature over that of normal background tissue. Preferential arterial images can be obtained by either increasing the VENC value to selectively suppress signal from slow flow in the veins or by subtracting the diastolic phase image from the peak systolic phase image. J. Magn. Reson. Imaging 2001;13:714-721.


Subject(s)
Image Enhancement , Image Processing, Computer-Assisted , Leg/blood supply , Magnetic Resonance Angiography , Magnetic Resonance Imaging, Cine , Tibial Arteries/anatomy & histology , Adult , Artifacts , Blood Flow Velocity/physiology , Contrast Media , Female , Gadolinium , Heterocyclic Compounds , Humans , Male , Middle Aged , Organometallic Compounds , Reference Values , Sensitivity and Specificity , Systole/physiology
14.
Radiology ; 219(3): 835-41, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11376279

ABSTRACT

A method of three-station three-dimensional magnetic resonance (MR) angiography of the lower extremities with segmented volume acquisition is presented. Three-dimensional MR angiographic data were acquired in two passes, with the central k-space views acquired during the arterial phase for the more proximal stations. This allowed a faster bolus injection rate and potentially improved visualization of the tibioperoneal arteries.


Subject(s)
Leg/blood supply , Magnetic Resonance Angiography/methods , Adult , Case-Control Studies , Contrast Media , Feasibility Studies , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Tibial Arteries/anatomy & histology , Time Factors
15.
Radiology ; 219(1): 258-63, 2001 Apr.
Article in English | MEDLINE | ID: mdl-11274567

ABSTRACT

The authors evaluated a magnetization preparation scheme with a "notched" section profile for T1-weighted first-pass myocardial perfusion magnetic resonance (MR) imaging at 1.5 T. The pulse sequence consisted of a preparation sequence followed by an interleaved gradient-echo echo-planar sequence. Image contrast was evaluated in a feasibility study in 12 adult patients. The notched saturation pulse allowed long magnetization recovery times without sacrificing section coverage. Image contrast between normal and ischemic myocardium was excellent.


Subject(s)
Coronary Disease/diagnosis , Echo-Planar Imaging/methods , Electrocardiography , Image Enhancement , Adenosine , Aged , Contrast Media , Exercise Test , Feasibility Studies , Female , Gadolinium DTPA , Humans , Male , Middle Aged , Myocardial Ischemia/diagnosis
16.
J Magn Reson Imaging ; 12(5): 769-75, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11050649

ABSTRACT

In this pilot study, using a standard 40 mL gadolinium (Gd) chelate contrast dose, dual-rate (first 20 mL at 0.5 mL/sec; remaining 20 mL at 1.5 mL/sec) and fixed-rate (entire 40 mL dose at either 0.7 mL/sec or 2.0 mL/sec) injection schemes for multistation, bolus-chase magnetic resonance angiography (MRA) were compared in normal volunteers. Signal-to-noise ratio, contrast-to-noise ratio, and physician preference were determined for nine arterial segments. At the terminal station (calf), the dual-rate contrast injection improved arterial signal and contrast compared with both fixed-rate injection schemes and improved subjective vessel appearance compared with the 2.0 mL/sec, but not the 0.7 mL/sec, fixed-rate scheme.


Subject(s)
Contrast Media , Gadolinium , Magnetic Resonance Angiography/methods , Adult , Analysis of Variance , Arteries/anatomy & histology , Dose-Response Relationship, Drug , Female , Humans , Injections, Intravenous , Male , Middle Aged , Pilot Projects , Radiographic Image Enhancement , Reference Values , Sensitivity and Specificity , Time Factors
17.
Magn Reson Med ; 43(6): 892-5, 2000 Jun.
Article in English | MEDLINE | ID: mdl-10861885

ABSTRACT

A connectivity algorithm combined with a new gray-level morphological filter dramatically improves the segmentation of tortuous coronary arteries from 3D MRI. Small coronary arteries are segmented from the larger ventricles with a new filter. These blood vessels are segmented from the noise background with connectivity. Coronary angiograms were computed in nine datasets acquired on volunteers with 3D stack of spirals and contrast-enhanced navigator sequences by both a maximum intensity projection and surface rendering. Surface images provided depth information needed to distinguish branching arteries from crossing veins. Magn Reson Med 43:892-895, 2000.


Subject(s)
Coronary Vessels/anatomy & histology , Image Enhancement/methods , Magnetic Resonance Angiography/instrumentation , Algorithms , Coronary Circulation/physiology , Humans , Magnetic Resonance Angiography/methods , Reference Values , Sensitivity and Specificity
18.
Radiology ; 214(1): 283-9, 2000 Jan.
Article in English | MEDLINE | ID: mdl-10644138

ABSTRACT

To follow the motion of the coronary artery in magnetic resonance angiography, the authors evaluated vessel tracking, a method for prospective adjustment of the section location as a function of the delay from the cardiac trigger. In 10 volunteers and four patients, this method allowed the vessel to be maintained in the plane of acquisition throughout the cardiac cycle. With a single-phase multisection sequence, vessel-tracking acquisitions had an efficiency of 0.68 +/- 0.04 for both the right and left coronary arteries compared with 0.19 +/- 0.03 for a non-vessel-tracking acquisition (P < .001).


Subject(s)
Coronary Angiography , Coronary Vessels/pathology , Magnetic Resonance Angiography , Myocardial Contraction/physiology , Adult , Aged , Artifacts , Electrocardiography , Female , Humans , Male , Middle Aged , Reference Values
19.
Top Magn Reson Imaging ; 11(6): 406-16, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11153707

ABSTRACT

Coronary artery magnetic resonance imaging strategies have tended to focus on the use of a single method performed during either breath-holding or free-breathing for all patients. However, significant variations exist among patients in terms of breath-holding ability and respiratory regularity that make the use of a single technique alone not universally successful. Therefore, it is prudent to make available a number of magnetic resonance imaging methods such that an appropriate respiratory motion reduction strategy can be tailored to suit the patient's respiratory pattern and characteristics. A tailored approach that can draw on different image acquisition techniques for coronary artery imaging is presented. A decision tree is proposed to triage patients into imaging regimes with the greatest probability of success, according to the patient's ability to breath-hold or exhibit steady respiration. Methods include volume free-breathing acquisitions using navigator echoes for respiratory monitoring in the 8- to 10-min scan time range, two-dimensional spiral navigators (2- to 3-min scan time), breath-held multislice and vessel-tracking spirals (16- to 20-second scan time), and real-time imaging approaches incorporating adaptive signal averaging. The development of multiple acquisition strategies substantially improves the opportunities to generate high-quality, diagnostic images of the coronary arteries.


Subject(s)
Coronary Disease/diagnosis , Coronary Vessels/anatomy & histology , Magnetic Resonance Angiography/methods , Patient-Centered Care , Respiration , Female , Humans , Male , Sensitivity and Specificity
20.
J Magn Reson Imaging ; 10(3): 376-88, 1999 Sep.
Article in English | MEDLINE | ID: mdl-10508299

ABSTRACT

Bolus chase 3-dimensional MR angiography (3D MRA) is a recent development that extends the effective field of view for arterial imaging from the typical single 40-50 cm to over 100 cm. This technique is well suited for imaging long vascular territories such as the lower extremity. Bolus chase peripheral 3D MRA is achieved with overlapping 3D gradient-echo scans during the arterial transit of a single intravenous injection of gadolinium-chelate contrast media. This technique can depict the arteries from the infrarenal aorta to the ankles in less than 2 minutes. The initial experiences with bolus chase peripheral MRA using an automated algorithm that controls both table translation and 3D data acquisition are described. Suggestions for future refinements to the technique are also discussed.


Subject(s)
Contrast Media/administration & dosage , Gadolinium/administration & dosage , Image Enhancement/methods , Magnetic Resonance Angiography/methods , Peripheral Vascular Diseases/diagnosis , Algorithms , Fourier Analysis , Humans , Injections, Intravenous
SELECTION OF CITATIONS
SEARCH DETAIL
...