Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Nanotechnology ; 33(16)2022 Jan 24.
Article in English | MEDLINE | ID: mdl-34915461

ABSTRACT

We report sensing of single nanoparticles using disordered metallic nanoisland substrates supporting surface plasmon polaritons (SPPs). Speckle patterns arising from leakage radiation of elastically scattered SPPs provide a unique fingerprint of the scattering microstructure at the sensor surface. Experimental measurements of the speckle decorrelation are presented and shown to enable detection of sorption of individual gold nanoparticles and polystyrene beads. Our approach is verified through bright-field and fluorescence imaging of particles adhering to the nanoisland substrate.

2.
Opt Lett ; 46(10): 2477-2480, 2021 May 15.
Article in English | MEDLINE | ID: mdl-33988614

ABSTRACT

Small perturbations in the dielectric environment around resonant dielectric structures usually lead to a frequency shift of the resonator modes directly proportional to the polarizability of the perturbation. Here, we report experimental observations of strong frequency shifts that can oppose and even exceed the contribution of the perturbations' polarizability. We show in particular how the mode frequencies of a lithium niobate whispering-gallery-mode resonator are shifted by planar substrates-of refractive indices ranging from 1.50 to 4.22-contacting the resonator rim. Both blue- and redshifts are observed, as well as an increase in mode linewidth, when substrates are moved into the evanescent field of the whispering gallery mode. We compare the experimental results to a theoretical model by Foreman et al. [J. Opt. Soc. Am. B33, 2177 (2016)JOBPDE0740-322410.1364/JOSAB.33.002177] and provide an additional intuitive explanation based on the Goos-Hänchen shift for the optical domain, with applications to dielectric structures ranging from meta-surfaces to photonic crystal cavities.

3.
Sensors (Basel) ; 20(24)2020 Dec 10.
Article in English | MEDLINE | ID: mdl-33321811

ABSTRACT

Compensatory movements at the trunk are commonly utilized during reaching by persons with motor impairments due to neurological injury such as stroke. Recent low-cost motion sensors may be able to measure trunk compensation, but their validity and reliability for this application are unknown. The purpose of this study was to compare the first (K1) and second (K2) generations of the Microsoft Kinect to a video motion capture system (VMC) for measuring trunk compensation during reaching. Healthy participants (n = 5) performed reaching movements designed to simulate trunk compensation in three different directions and on two different days while being measured by all three sensors simultaneously. Kinematic variables related to reaching range of motion (ROM), planar reach distance, trunk flexion and lateral flexion, shoulder flexion and lateral flexion, and elbow flexion were calculated. Validity and reliability were analyzed using repeated-measures ANOVA, paired t-tests, Pearson's correlations, and Bland-Altman limits of agreement. Results show that the K2 was closer in magnitude to the VMC, more valid, and more reliable for measuring trunk flexion and lateral flexion during extended reaches than the K1. Both sensors were highly valid and reliable for reaching ROM, planar reach distance, and elbow flexion for all conditions. Results for shoulder flexion and abduction were mixed. The K2 was more valid and reliable for measuring trunk compensation during reaching and therefore might be prioritized for future development applications. Future analyses should include a more heterogeneous clinical population such as persons with chronic hemiparetic stroke.


Subject(s)
Shoulder , Torso , Biomechanical Phenomena , Humans , Movement , Range of Motion, Articular , Reproducibility of Results , Video Recording
4.
Opt Lett ; 45(20): 5740-5743, 2020 Oct 15.
Article in English | MEDLINE | ID: mdl-33057273

ABSTRACT

Polarimetric imaging can provide valuable information about biological samples in a wide range of applications. Detrimental tissue scattering and depolarization however currently hamper in vivo polarization imaging. In this work, single pixel imaging is investigated as a means of reconstructing polarimetric images through scattering media. A theoretical imaging model is presented, and the recovery of the spatially resolved Mueller matrix of a test object behind a scattering phantom is demonstrated experimentally.


Subject(s)
Molecular Imaging/methods , Scattering, Radiation , Phantoms, Imaging
5.
Biomed Opt Express ; 11(2): 1020-1031, 2020 Feb 01.
Article in English | MEDLINE | ID: mdl-32133235

ABSTRACT

Brillouin spectroscopy can suffer from low signal-to-noise ratios (SNRs). Such low SNRs can render common data analysis protocols unreliable, especially for SNRs below ∼10. In this work we exploit two denoising algorithms, namely maximum entropy reconstruction (MER) and wavelet analysis (WA), to improve the accuracy and precision in determination of Brillouin shifts and linewidth. Algorithm performance is quantified using Monte-Carlo simulations and benchmarked against the Cramér-Rao lower bound. Superior estimation results are demonstrated even at low SNRs (≥ 1). Denoising is furthermore applied to experimental Brillouin spectra of distilled water at room temperature, allowing the speed of sound in water to be extracted. Experimental and theoretical values were found to be consistent to within ±1% at unity SNR.

6.
Phys Rev Lett ; 123(5): 059901, 2019 Aug 02.
Article in English | MEDLINE | ID: mdl-31491317

ABSTRACT

This corrects the article DOI: 10.1103/PhysRevLett.115.263901.

7.
J Rehabil Assist Technol Eng ; 6: 2055668318823673, 2019.
Article in English | MEDLINE | ID: mdl-31245028

ABSTRACT

Background: Compensatory movement, such as flexing the trunk during reaching, may negatively affect motor improvement during task-based practice for persons with stroke. Shaping, or incrementally decreasing, the amount of compensation used during rehabilitation may be a viable strategy with methods using virtual reality. Methods: A virtual reality tool was designed to (1) monitor upper extremity movement kinematics with an off-the-shelf motion sensor (Microsoft Kinect V2), (2) convert movements into control of widely available computer games, and (3) provide real-time feedback to shape trunk compensation. This system was tested for feasibility by a small cohort of participants with chronic stroke (n = 5) during a 1-h session involving 40 min of virtual reality interaction. Outcomes related to repetitions, compensation, movement kinematics, usability, motivation, and sense of presence were collected. Results: Participants achieved a very high dose of reaching repetitions (461 ± 184), with an average of 81% being successful and 19% involving compensatory trunk flexion. Participants rated the system as highly usable, motivating, engaging, and safe. Conclusions: VRShape is feasible to use as a tool for increasing repetition rates, measuring and shaping compensation, and enhancing motivation for upper extremity therapy. Future research should focus on software improvements and investigation of efficacy during a virtual reality-based motor intervention.

8.
Sci Rep ; 9(1): 8359, 2019 Jun 07.
Article in English | MEDLINE | ID: mdl-31175316

ABSTRACT

In this work fluctuations in the electric field of surface plasmon polaritons undergoing random scattering on a rough metallic surface are considered. A rigorous closed form analytic expression is derived describing second order correlations in the resulting plasmon speckle pattern assuming statistically stationary and isotropic roughness. Partially coherent planar Schell-model source fields can also be described within the developed framework. Behaviour of the three-dimensional degree of cross polarisation and spectral degree of coherence is also discussed. Expressions derived take full account of dissipation in the metal with non-universal behaviour exhibited within the correlation length of the surface and source fields.

9.
Sci Rep ; 9(1): 6140, 2019 Apr 16.
Article in English | MEDLINE | ID: mdl-30992485

ABSTRACT

Using Fisher information and the Cramér-Rao lower bound, we analyse fundamental precision limits in the determination of spectral parameters in inelastic optical scattering. General analytic formulae are derived which account for the instrument response functions of the dispersive element and relay optics found in practical Raman and Brillouin spectrometers. Limiting cases of dispersion and diffraction limited spectrometers, corresponding to measurement of Lorentzian and Voigt lineshapes respectively, are discussed in detail allowing optimal configurations to be identified. Effects of defocus, spherical aberration, detector pixelation and a finite detector size are also considered.

10.
Am J Occup Ther ; 73(1): 7301347010p1-7301347010p6, 2019.
Article in English | MEDLINE | ID: mdl-30839272

ABSTRACT

Performance of many activities of daily living and instrumental activities of daily living involve technology, such as an electric toothbrush or a self-checkout register at the grocery store. Unfortunately, more than 60 million people with disabilities in the United States struggle to use these technologies because of inaccessible designs. Occupational therapy practitioners have a unique expertise in the design of accessible equipment. Practitioners have been involved in the design of adaptive and assistive equipment targeting use by people with disabilities since occupational therapy's beginnings. However, few occupational therapy professionals currently work in the research and development of everyday technologies. This article explores the role of the occupational therapy practitioner on the technology design team, discusses barriers to current practice, and makes recommendations to the profession.


Subject(s)
Disabled Persons , Occupational Therapy , Self-Help Devices , Activities of Daily Living , Humans , Research , United States
11.
Disabil Rehabil Assist Technol ; 13(1): 54-59, 2018 01.
Article in English | MEDLINE | ID: mdl-28102090

ABSTRACT

PURPOSE: Studies have shown that marker-less motion detection systems, such as the first generation Kinect (Kinect 1), have good reliability and potential for clinical application. Studies of the second generation Kinect (Kinect 2) have shown a large range of accuracy relative to balance and joint localization; however, few studies have investigated the validity and reliability of the Kinect 2 for upper extremity motion. This investigation compared reliability and validity among the Kinect 1, Kinect 2 and a video motion capture (VMC) system for upper extremity movements. DESIGN: One healthy, adult male performed six upper extremity movements during two separate sessions. All movements were recorded on the Kinect 1, Kinect 2 and VMC simultaneously. Data were analyzed using MATLAB (Natick, MA), Microsoft Excel (Redmond, WA), and SPSS (Armonk, NY). RESULTS: Results indicated good reliability for both Kinects within a day; results between days were inconclusive for both devices due to the inability to exactly repeat the desired movements. Range of motion (ROM) magnitudes for both Kinects were different from the VMC, yet patterns of motion were very highly correlated for both devices. CONCLUSION: Simple transformations of Kinect data could bring magnitudes in line with those of the VMC, allowing the Kinects to be used in a clinical setting. Implications for Rehabilitation The clinical implications of the investigation support the notion that the Kinects could be used in the clinical setting if an understanding of their limitations exists. Using the Kinects to make assessments with a given data collection session is acceptable. Using the Kinects to make comparisons across different days such as before or after an intervention should be approached with caution. The Kinect 2 provides a more cost effective option compared to the VMC. Additionally, the Kinect is more portable, requires less time to set-up, and takes up less space, thus increasing its overall usability compared to the VMC.


Subject(s)
Movement , Physical Therapy Modalities/standards , Video Games/standards , Adult , Biomechanical Phenomena , Humans , Male , Range of Motion, Articular , Reproducibility of Results , Upper Extremity , Video Games/economics
12.
Opt Lett ; 42(5): 963-966, 2017 Mar 01.
Article in English | MEDLINE | ID: mdl-28248342

ABSTRACT

Interactions between whispering gallery modes (WGMs) and small nanoparticles are commonly modeled by treating the particle as a point dipole scatterer. This approach is assumed to be accurate as long as the nanoparticle radius, a, is small compared to the WGM wavelength λ. In this Letter, however, we show that the large field gradients associated with the evanescent decay of a WGM causes the dipole theory to significantly underestimate the interaction strength and, hence, the induced WGM resonance shift, even for particles as small as a∼λ/10. To mitigate this issue, we employ a renormalized Born approximation to more accurately determine nanoparticle-induced resonance shifts and, hence, enable improved particle sizing. The domain of validity of this approximation is investigated, and supporting experimental results are presented.

13.
Gait Posture ; 52: 202-204, 2017 02.
Article in English | MEDLINE | ID: mdl-27915225

ABSTRACT

INTRODUCTION: Improving gait speed and kinematics can be a time consuming and tiresome process. We hypothesize that incorporating virtual reality videogame play into variable improvement goals will improve levels of enjoyment and motivation and lead to improved gait performance. PURPOSE: To develop a feasible, engaging, VR gait intervention for improving gait variables. METHODS: Completing this investigation involved four steps: 1) identify gait variables that could be manipulated to improve gait speed and kinematics using the Microsoft Kinect and free software, 2) identify free internet videogames that could successfully manipulate the chosen gait variables, 3) experimentally evaluate the ability of the videogames and software to manipulate the gait variables, and 4) evaluate the enjoyment and motivation from a small sample of persons without disability. RESULTS: The Kinect sensor was able to detect stride length, cadence, and joint angles. FAAST software was able to identify predetermined gait variable thresholds and use the thresholds to play free online videogames. Videogames that involved continuous pressing of a keyboard key were found to be most appropriate for manipulating the gait variables. Five participants without disability evaluated the effectiveness for modifying the gait variables and enjoyment and motivation during play. Participants were able to modify gait variables to permit successful videogame play. Motivation and enjoyment were high. SUMMARY: A clinically feasible and engaging virtual intervention for improving gait speed and kinematics has been developed and initially tested. It may provide an engaging avenue for achieving thousands of repetitions necessary for neural plastic changes and improved gait.


Subject(s)
Gait , Virtual Reality , Walking , Biomechanical Phenomena , Female , Humans , Male , Physical Therapy Modalities , Software
14.
Behav Sci (Basel) ; 6(2)2016 Jun 07.
Article in English | MEDLINE | ID: mdl-27338485

ABSTRACT

Movement therapy is one type of upper extremity intervention for children with cerebral palsy (CP) to improve function. It requires high-intensity, repetitive and task-specific training. Tedium and lack of motivation are substantial barriers to completing the training. An approach to overcome these barriers is to couple the movement therapy with videogames. This investigation: (1) tested the feasibility of delivering a free Internet videogame upper extremity motor intervention to four children with CP (aged 8-17 years) with mild to moderate limitations to upper limb function; and (2) determined the level of intrinsic motivation during the intervention. The intervention used free Internet videogames in conjunction with the Microsoft Kinect motion sensor and the Flexible Action and Articulated Skeleton Toolkit software (FAAST) software. Results indicated that the intervention could be successfully delivered in the laboratory and the home, and pre- and post- impairment, function and performance assessments were possible. Results also indicated a high level of motivation among the participants. It was concluded that the use of inexpensive hardware and software in conjunction with free Internet videogames has the potential to be very motivating in helping to improve the upper extremity abilities of children with CP. Future work should include results from additional participants and from a control group in a randomized controlled trial to establish efficacy.

15.
Nanotechnology ; 27(22): 224002, 2016 Jun 03.
Article in English | MEDLINE | ID: mdl-27114455

ABSTRACT

Plasmonic metasurfaces enable simultaneous control of the phase, momentum, amplitude and polarization of light and hence promise great utility in realization of compact photonic devices. In this paper, we demonstrate a novel chip-scale device suitable for simultaneous polarization and spectral measurements through use of six integrated plasmonic metasurfaces (IPMs), which diffract light with a given polarization state and spectral component into well-defined spatial domains. Full calibration and characterization of our device is presented, whereby good spectral resolution and polarization accuracy over a wavelength range of 500-700 nm is shown. Functionality of our device in a Müller matrix modality is demonstrated through determination of the polarization properties of a commercially available variable waveplate. Our proposed IPM is robust, compact and can be fabricated with a single photolithography step, promising many applications in polarization imaging, quantum communication and quantitative sensing.

16.
J Rehabil Res Dev ; 53(6): 901-918, 2016.
Article in English | MEDLINE | ID: mdl-28475198

ABSTRACT

Concurrent validity and test-retest reliability of the Microsoft Kinect in quantification of manual wheelchair propulsion were examined. Data were collected from five manual wheelchair users on a roller system. Three Kinect sensors were used to assess test-retest reliability with a still pose. Three systems were used to assess concurrent validity of the Kinect to measure propulsion kinematics (joint angles, push loop characteristics): Kinect, Motion Analysis, and Dartfish ProSuite (Dartfish joint angles were limited to shoulder and elbow flexion). Intraclass correlation coefficients revealed good reliability (0.87-0.99) between five of the six joint angles (neck flexion, shoulder flexion, shoulder abduction, elbow flexion, wrist flexion). ICCs suggested good concurrent validity for elbow flexion between the Kinect and Dartfish and between the Kinect and Motion Analysis. Good concurrent validity was revealed for maximum height, hand-axle relationship, and maximum area (0.92-0.95) between the Kinect and Dartfish and maximum height and hand-axle relationship (0.89-0.96) between the Kinect and Motion Analysis. Analysis of variance revealed significant differences (p < 0.05) in maximum length between Dartfish (mean 58.76 cm) and the Kinect (40.16 cm). Results pose promising research and clinical implications for propulsion assessment and overuse injury prevention with the application of current findings to future technology.


Subject(s)
Elbow Joint , Equipment Design , Range of Motion, Articular , Shoulder , Wheelchairs , Biomechanical Phenomena , Humans , Reproducibility of Results
17.
Phys Rev Lett ; 114(11): 118001, 2015 Mar 20.
Article in English | MEDLINE | ID: mdl-25839311

ABSTRACT

In this Letter we propose the use of whispering gallery mode resonance tracking as a label-free optical means to monitor diffusion kinetics in glassy polymer microspheres. Approximate solutions to the governing diffusion equations are derived for the case of slow relaxation and small Stefan number. Transduction of physical changes in the polymer, including formation of a rubbery layer, swelling, and dissolution, into detectable resonance shifts are described using a perturbative approach. Concrete examples of poly(methyl methacrylate) and polystyrene spheres in water are considered.


Subject(s)
Microspheres , Models, Chemical , Polymethyl Methacrylate/chemistry , Polystyrenes/chemistry , Diffusion , Kinetics , Water/chemistry
18.
Adv Opt Photonics ; 7(2): 168-240, 2015 Jun 30.
Article in English | MEDLINE | ID: mdl-26973759

ABSTRACT

We present a comprehensive overview of sensor technology exploiting optical whispering gallery mode (WGM) resonances. After a short introduction we begin by detailing the fundamental principles and theory of WGMs in optical microcavities and the transduction mechanisms frequently employed for sensing purposes. Key recent theoretical contributions to the modeling and analysis of WGM systems are highlighted. Subsequently we review the state of the art of WGM sensors by outlining efforts made to date to improve current detection limits. Proposals in this vein are numerous and range, for example, from plasmonic enhancements and active cavities to hybrid optomechanical sensors, which are already working in the shot noise limited regime. In parallel to furthering WGM sensitivity, efforts to improve the time resolution are beginning to emerge. We therefore summarize the techniques being pursued in this vein. Ultimately WGM sensors aim for real-world applications, such as measurements of force and temperature, or alternatively gas and biosensing. Each such application is thus reviewed in turn, and important achievements are discussed. Finally, we adopt a more forward-looking perspective and discuss the outlook of WGM sensors within both a physical and biological context and consider how they may yet push the detection envelope further.

19.
Phys Rev Lett ; 115(26): 263901, 2015 Dec 31.
Article in English | MEDLINE | ID: mdl-26764991

ABSTRACT

Complete determination of the polarization state of light requires at least four distinct projective measurements of the associated Stokes vector. Stability of state reconstruction, however, hinges on the condition number κ of the corresponding instrument matrix. Optimization of redundant measurement frames with an arbitrary number of analysis states, m, is considered in this Letter in the sense of minimization of κ. The minimum achievable κ is analytically found and shown to be independent of m, except for m=5 where this minimum is unachievable. Distribution of the optimal analysis states over the Poincaré sphere is found to be described by spherical 2 designs, including the Platonic solids as special cases. Higher order polarization properties also play a key role in nonlinear, stochastic, and quantum processes. Optimal measurement schemes for nonlinear measurands of degree t are hence also considered and found to correspond to spherical 2t designs, thereby constituting a generalization of the concept of mutually unbiased bases.

20.
Nat Nanotechnol ; 9(11): 933-9, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25173831

ABSTRACT

Biosensing relies on the detection of molecules and their specific interactions. It is therefore highly desirable to develop transducers exhibiting ultimate detection limits. Microcavities are an exemplary candidate technology for demonstrating such a capability in the optical domain and in a label-free fashion. Additional sensitivity gains, achievable by exploiting plasmon resonances, promise biosensing down to the single-molecule level. Here, we introduce a biosensing platform using optical microcavity-based sensors that exhibits single-molecule sensitivity and is selective to specific single binding events. Whispering gallery modes in glass microspheres are used to leverage plasmonic enhancements in gold nanorods for the specific detection of nucleic acid hybridization, down to single 8-mer oligonucleotides. Detection of single intercalating small molecules confirms the observation of single-molecule hybridization. Matched and mismatched strands are discriminated by their interaction kinetics. Our platform allows us to monitor specific molecular interactions transiently, hence mitigating the need for high binding affinity and avoiding permanent binding of target molecules to the receptors. Sensor lifetime is therefore increased, allowing interaction kinetics to be statistically analysed.


Subject(s)
Gold/chemistry , Nanotubes/chemistry , Nucleic Acid Hybridization , Nucleic Acids/analysis , Surface Plasmon Resonance/instrumentation , Equipment Design , Nanotubes/ultrastructure
SELECTION OF CITATIONS
SEARCH DETAIL
...