Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Mol Diagn ; 19(3): 404-416, 2017 05.
Article in English | MEDLINE | ID: mdl-28433077

ABSTRACT

Nearly 80% of cancer patients do not have genetic mutation results available at initial oncology consultation; up to 25% of patients begin treatment before receiving their results. These factors hinder the ability to pursue optimal treatment strategies. This study validates a blood-based genome-testing service that provides accurate results within 72 hours. We focused on targetable variants in advanced non-small cell lung carcinoma-epidermal growth factor receptor gene (EGFR) variant L858R, exon 19 deletion (ΔE746-A750), and T790M; GTPase Kirsten ras gene (KRAS) variants G12C/D/V; and echinoderm microtubule associated protein like and 4 anaplastic lymphoma receptor tyrosine kinase fusion (EML4-ALK) transcripts 1/2/3. Test development included method and clinical validation using samples from donors with (n = 219) or without (n = 30) cancer. Clinical sensitivity and specificity for each variant ranged from 78.6% to 100% and 94.2% to 100%, respectively. We also report on 1643 non-small cell lung carcinoma samples processed in our CLIA-certified laboratory. Mutation results were available within 72 hours for 94% of the tests evaluated. We detected 10.5% mutations for EGFR sensitizing (n = 2801 samples tested), 13.8% mutations for EGFR resistance (n = 1055), 13.2% mutations in KRAS (n = 3477), and 2% mutations for EML4-ALK fusion (n = 304). This rapid, highly sensitive, and actionable blood-based assay service expands testing options and supports faster treatment decisions.


Subject(s)
Carcinoma, Non-Small-Cell Lung/genetics , DNA Mutational Analysis/methods , Anaplastic Lymphoma Kinase , Cell Cycle Proteins/genetics , ErbB Receptors/genetics , Exons/genetics , Humans , Lung Neoplasms/genetics , Microtubule-Associated Proteins/genetics , Mutation , Oncogene Proteins, Fusion/genetics , Proto-Oncogene Proteins p21(ras)/genetics , Receptor Protein-Tyrosine Kinases/genetics , Serine Endopeptidases/genetics
2.
Eur Heart J ; 36(48): 3426-34, 2015 Dec 21.
Article in English | MEDLINE | ID: mdl-26294790

ABSTRACT

AIMS: Growth differentiation factor 11 and/or its homologue growth differentiation factor 8 (GDF11/8) reverses age-related cardiac hypertrophy and vascular ageing in mice. We investigated whether GDF11/8 associates with cardiovascular outcomes, left ventricular hypertrophy (LVH), or age in humans. METHODS AND RESULTS: We measured plasma GDF11/8 levels in 928 participants with stable ischaemic heart disease in the Heart and Soul study. We adjudicated heart failure hospitalization, stroke, myocardial infarction, death, and their composite endpoint. Left ventricular hypertrophy was evaluated by echocardiography. We used multivariable Cox proportional hazards models to compare rates of cardiovascular events and death across GDF11/8 quartiles and logistic regression models to evaluate the association between GDF11/8 and LVH. Four hundred and fifty participants (48.5%) experienced a cardiovascular event or death during 8.9 years of follow-up. The adjusted risk of the composite endpoint was lower in the highest compared with the lowest GDF11/8 quartile [hazard ratio (HR), 0.45; 95% confidence interval (CI), 0.33-0.60; P < 0.001]. We replicated this relationship of GDF11/8 to adverse events in 971 participants in the HUNT3 cohort (adjusted HR, 0.34; 95% CI, 0.23-0.51; P < 0.001). Left ventricular hypertrophy was present in 368 participants (39.7%) at baseline. Participants in the highest quartile of GDF11/8 were less likely to have LVH than those in the lowest quartile (adjusted OR, 0.55; 95% CI, 0.35-0.86; P = 0.009). GDF11/8 levels were lower in older individuals (P < 0.001). CONCLUSION: In patients with stable ischaemic heart disease, higher GDF11/8 levels are associated with lower risk of cardiovascular events and death. Our findings suggest that GDF11/8 has similar cardioprotective properties in humans to those demonstrated in mice.


Subject(s)
Bone Morphogenetic Proteins/metabolism , Growth Differentiation Factor 9/metabolism , Growth Differentiation Factors/metabolism , Hypertrophy, Left Ventricular/mortality , Myocardial Ischemia/mortality , Age Factors , Aged , Coronary Disease/blood , Coronary Disease/mortality , Female , Heart Failure/blood , Heart Failure/mortality , Humans , Hypertrophy, Left Ventricular/blood , Male , Myocardial Ischemia/blood , Prognosis , Prospective Studies , Risk Factors , Stroke/blood , Stroke/mortality
3.
PLoS One ; 5(12): e15004, 2010 Dec 07.
Article in English | MEDLINE | ID: mdl-21165148

ABSTRACT

BACKGROUND: The interrogation of proteomes ("proteomics") in a highly multiplexed and efficient manner remains a coveted and challenging goal in biology and medicine. METHODOLOGY/PRINCIPAL FINDINGS: We present a new aptamer-based proteomic technology for biomarker discovery capable of simultaneously measuring thousands of proteins from small sample volumes (15 µL of serum or plasma). Our current assay measures 813 proteins with low limits of detection (1 pM median), 7 logs of overall dynamic range (~100 fM-1 µM), and 5% median coefficient of variation. This technology is enabled by a new generation of aptamers that contain chemically modified nucleotides, which greatly expand the physicochemical diversity of the large randomized nucleic acid libraries from which the aptamers are selected. Proteins in complex matrices such as plasma are measured with a process that transforms a signature of protein concentrations into a corresponding signature of DNA aptamer concentrations, which is quantified on a DNA microarray. Our assay takes advantage of the dual nature of aptamers as both folded protein-binding entities with defined shapes and unique nucleotide sequences recognizable by specific hybridization probes. To demonstrate the utility of our proteomics biomarker discovery technology, we applied it to a clinical study of chronic kidney disease (CKD). We identified two well known CKD biomarkers as well as an additional 58 potential CKD biomarkers. These results demonstrate the potential utility of our technology to rapidly discover unique protein signatures characteristic of various disease states. CONCLUSIONS/SIGNIFICANCE: We describe a versatile and powerful tool that allows large-scale comparison of proteome profiles among discrete populations. This unbiased and highly multiplexed search engine will enable the discovery of novel biomarkers in a manner that is unencumbered by our incomplete knowledge of biology, thereby helping to advance the next generation of evidence-based medicine.


Subject(s)
Aptamers, Nucleotide , Biomarkers/metabolism , Proteomics/methods , Aged , Evidence-Based Medicine , Female , Gene Library , Genetic Techniques , Glomerular Filtration Rate , Humans , Kidney Failure, Chronic/metabolism , Kinetics , Male , Mass Spectrometry/methods , Middle Aged , Nucleic Acid Hybridization , Oligonucleotide Array Sequence Analysis , Proteome , Reproducibility of Results
4.
J Proteomics ; 73(3): 649-66, 2010 Jan 03.
Article in English | MEDLINE | ID: mdl-19755178

ABSTRACT

Blood-based protein biomarkers hold great promise to advance medicine with applications that detect and diagnose diseases and aid in their treatment. We are developing such applications with our proteomics technology that combines high-content with low limits of detection. Biomarker discovery relies heavily on archived blood sample collections. Blood is dynamic and changes with different sampling procedures potentially confounding biomarker studies. In order to better understand the effects of sampling procedures on the circulating proteome, we studied three sample collection variables commonly encountered in archived sample sets. These variables included (1) three different sample tube types, PPT plasma, SST serum, and Red Top serum, (2) the time from venipuncture to centrifugation, and (3) the time from centrifugation to freezing. We profiled 498 proteins for each of 240 samples and compared the results by ANOVA. The results found no significant variation in the measurements for most proteins (approximately 99%) when the two sample processing times tested were 2h or less, regardless of sample tube type. Even at the longest timepoints, 20 h, approximately 82% of the proteins, on average for the three collection tube types, showed no significant change. These results are encouraging for proteomic biomarker discovery.


Subject(s)
Blood Proteins/metabolism , Blood Specimen Collection/methods , Protein Stability , Proteome/analysis , Proteome/metabolism , SELEX Aptamer Technique/methods , Algorithms , Aptamers, Peptide/chemistry , Blood Coagulation/physiology , Blood Preservation/adverse effects , Blood Preservation/methods , Blood Proteins/analysis , Blood Specimen Collection/adverse effects , Blood Specimen Collection/standards , Cluster Analysis , Freezing/adverse effects , Humans , Models, Biological , Observer Variation , Protein Array Analysis/instrumentation , Protein Array Analysis/methods , Proteomics/instrumentation , Proteomics/methods , SELEX Aptamer Technique/instrumentation , Time Factors
5.
Article in English | MEDLINE | ID: mdl-12638707

ABSTRACT

Beryllium is an important industrial metal because of its unusual material properties: it is lighter than aluminum and six times stronger than steel. Often alloyed with other metals such as copper, beryllium is a key component of materials used in the aerospace and electronics industries. Beryllium has a small neutron cross-section, which makes it useful in the production of nuclear weapons and in sealed neutron sources. Unfortunately, beryllium is one of the most toxic elements in the periodic table. It is responsible for the often-fatal lung disease, Chronic Beryllium Disease (CBD) or berylliosis, and is listed as a Class A EPA carcinogen. Coal-fired power plants, industrial manufacturing and nuclear weapons production and disposal operations have released beryllium to the environment. This contamination has the potential to expose workers and the public to beryllium. Despite the increasing use of beryllium in industry, there is surprisingly little published information about beryllium fate and transport in the environment. This information is crucial for the development of strategies that limit worker and public exposure. This review summarizes the current understanding of beryllium health hazards, current regulatory mandates, environmental chemistry, geochemistry and environmental contamination.


Subject(s)
Beryllium/adverse effects , Beryllium/chemistry , Carcinogens/adverse effects , Carcinogens/chemistry , Environmental Exposure , Occupational Exposure , Environment , Environmental Monitoring , Humans , Ion Exchange , Public Health , Risk Assessment
SELECTION OF CITATIONS
SEARCH DETAIL
...